Mehrak Amjadi, Mohammad Raouf Safari, Ramin Dini Torkamani, Mohammadsepehr Kheiri Manjili, Davoud Jamshidi, Fatemeh Sobhan, Soolmaz Heidari
{"title":"Comparative Assessment of Post-Fatigue Resistance of Mandibular First Molars Restored With Polyether Ether Ketone and Lithium Disilicate Endocrowns.","authors":"Mehrak Amjadi, Mohammad Raouf Safari, Ramin Dini Torkamani, Mohammadsepehr Kheiri Manjili, Davoud Jamshidi, Fatemeh Sobhan, Soolmaz Heidari","doi":"10.1155/tswj/8648372","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background and Objectives:</b> Contemporary dentistry focuses on more conservative treatment options such as endocrown restorations and application of dental materials with higher resemblance to tooth structure. Polyether ether ketone (PEEK) polymer is a material used for the fabrication of endocrowns. This study aimed to compare the post-fatigue resistance (PFR) of mandibular first molars restored with PEEK and lithium disilicate (LS<sub>2</sub>) endocrown restorations. <b>Materials and Methods:</b> This in vitro, experimental study was conducted on 20 human mandibular first molars with similar dimensions. The teeth were prepared for endocrown restoration and were assigned to two groups (<i>n</i> = 10) of PEEK and LS<sub>2</sub> endocrowns. After fabrication by the computer-aided design and computer-aided manufacturing (CAD-CAM) technique, the restorations were cemented with resin cement. Next, the teeth underwent 15,000 thermal cycles followed by cyclic loading with 600,000 cycles of compressive force (100 N, 4 Hz) and were then subjected to compressive load application in a universal testing machine. The load causing endocrown failure was recorded as the PFR of the respective restoration. The failure mode was also inspected under a light microscope. Data were analyzed by the independent <i>t</i>-test and also chi-square, Mann-Whitney, and Fisher's exact tests (<i>α</i> < 0.05). <b>Results:</b> The teeth with PEEK endocrowns showed significantly higher PFR than those with LS<sub>2</sub> endocrowns. Irreparable fractures were dominant in both groups. <b>Conclusion:</b> PEEK may serve as a suitable alternative to LS<sub>2</sub> for the fabrication of endocrown restorations.</p>","PeriodicalId":22985,"journal":{"name":"The Scientific World Journal","volume":"2024 ","pages":"8648372"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11617050/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Scientific World Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/tswj/8648372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Objectives: Contemporary dentistry focuses on more conservative treatment options such as endocrown restorations and application of dental materials with higher resemblance to tooth structure. Polyether ether ketone (PEEK) polymer is a material used for the fabrication of endocrowns. This study aimed to compare the post-fatigue resistance (PFR) of mandibular first molars restored with PEEK and lithium disilicate (LS2) endocrown restorations. Materials and Methods: This in vitro, experimental study was conducted on 20 human mandibular first molars with similar dimensions. The teeth were prepared for endocrown restoration and were assigned to two groups (n = 10) of PEEK and LS2 endocrowns. After fabrication by the computer-aided design and computer-aided manufacturing (CAD-CAM) technique, the restorations were cemented with resin cement. Next, the teeth underwent 15,000 thermal cycles followed by cyclic loading with 600,000 cycles of compressive force (100 N, 4 Hz) and were then subjected to compressive load application in a universal testing machine. The load causing endocrown failure was recorded as the PFR of the respective restoration. The failure mode was also inspected under a light microscope. Data were analyzed by the independent t-test and also chi-square, Mann-Whitney, and Fisher's exact tests (α < 0.05). Results: The teeth with PEEK endocrowns showed significantly higher PFR than those with LS2 endocrowns. Irreparable fractures were dominant in both groups. Conclusion: PEEK may serve as a suitable alternative to LS2 for the fabrication of endocrown restorations.
期刊介绍:
The Scientific World Journal is a peer-reviewed, Open Access journal that publishes original research, reviews, and clinical studies covering a wide range of subjects in science, technology, and medicine. The journal is divided into 81 subject areas.