Naitao Li , Xiaoman Duan , Xiao Fan Ding , Ning Zhu , Xiongbiao Chen
{"title":"Characterization of hydrogel-scaffold mechanical properties and microstructure by using synchrotron propagation-based imaging","authors":"Naitao Li , Xiaoman Duan , Xiao Fan Ding , Ning Zhu , Xiongbiao Chen","doi":"10.1016/j.jmbbm.2024.106844","DOIUrl":null,"url":null,"abstract":"<div><div>Hydrogel-based scaffolds have been widely used in soft tissue regeneration due to their biocompatible and tissue-like environment for maintaining cellular functions and tissue regeneration. Understanding the mechanical properties and internal microstructure of hydrogel-based scaffold, once implanted, is imperative in tissue engineering applications and longitudinal studies. Notably, this has been challenging to date as various conventional characterization methods by, for example, mechanical testing (for mechanical properties) and microscope (for internal microstructure) are destructive as they require removing scaffolds from the implantation site and processing samples for characterization. Synchrotron radiation propagation-based imaging–computed tomography (SR-PBI-CT) is feasible and promising for non-destructive visualizing of hydrogel scaffolds. As inspired, this study aimed to perform a study on the characterization of mechanical properties and microstructure of hydrogel scaffolds based on the SR-PBI-CT.</div><div>In this study, hydrogel biomaterial inks composed of 3% w/v alginate and 1% w/v gelatin were printed to form scaffolds, with some scaffolds being degraded over 3 days. Both degraded and undegraded scaffolds underwent compressive testing, with the strains being controlled at the preset values; meanwhile stresses within scaffolds were measuring, resulting the stress-strain curves. Concurrently, the scaffolds were also imaged and examined by SR-PBI-CT at Canadian Light Source (CLS). During the imaging process, the scaffolds were mechanically loaded, respectively, with the strains same as the ones in the aforementioned compressive testing, and at each strain, the scaffold was scanned with a pixel size of 13 μm.</div><div>From the stress-strain curves obtained in the compression testing, the Young's modulus was evaluated to characterize the elastic behavior of scaffolds: with the range between around 5–25 kPa. From the images captured by SR-PBI-CT, the scaffolds microstructures were examined in terms of the strand cross-section area, pore size, and hydrogel volume. Further, from the SR-PBI-CT images, the stress within hydrogel of scaffolds were evaluated, showing the agreement with those obtained from compression testing. These results have illustrated that the mechanical properties and microstructures of scaffolds, ether being degraded or not, can be examined and characterized by the SR-PBI-CT imaging, in a non-destructive manner. This would represent a significant advance for facilitating longitudinal studies on the scaffolds once implanted <em>in-vivo</em>.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"163 ","pages":"Article 106844"},"PeriodicalIF":3.3000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616124004764","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Hydrogel-based scaffolds have been widely used in soft tissue regeneration due to their biocompatible and tissue-like environment for maintaining cellular functions and tissue regeneration. Understanding the mechanical properties and internal microstructure of hydrogel-based scaffold, once implanted, is imperative in tissue engineering applications and longitudinal studies. Notably, this has been challenging to date as various conventional characterization methods by, for example, mechanical testing (for mechanical properties) and microscope (for internal microstructure) are destructive as they require removing scaffolds from the implantation site and processing samples for characterization. Synchrotron radiation propagation-based imaging–computed tomography (SR-PBI-CT) is feasible and promising for non-destructive visualizing of hydrogel scaffolds. As inspired, this study aimed to perform a study on the characterization of mechanical properties and microstructure of hydrogel scaffolds based on the SR-PBI-CT.
In this study, hydrogel biomaterial inks composed of 3% w/v alginate and 1% w/v gelatin were printed to form scaffolds, with some scaffolds being degraded over 3 days. Both degraded and undegraded scaffolds underwent compressive testing, with the strains being controlled at the preset values; meanwhile stresses within scaffolds were measuring, resulting the stress-strain curves. Concurrently, the scaffolds were also imaged and examined by SR-PBI-CT at Canadian Light Source (CLS). During the imaging process, the scaffolds were mechanically loaded, respectively, with the strains same as the ones in the aforementioned compressive testing, and at each strain, the scaffold was scanned with a pixel size of 13 μm.
From the stress-strain curves obtained in the compression testing, the Young's modulus was evaluated to characterize the elastic behavior of scaffolds: with the range between around 5–25 kPa. From the images captured by SR-PBI-CT, the scaffolds microstructures were examined in terms of the strand cross-section area, pore size, and hydrogel volume. Further, from the SR-PBI-CT images, the stress within hydrogel of scaffolds were evaluated, showing the agreement with those obtained from compression testing. These results have illustrated that the mechanical properties and microstructures of scaffolds, ether being degraded or not, can be examined and characterized by the SR-PBI-CT imaging, in a non-destructive manner. This would represent a significant advance for facilitating longitudinal studies on the scaffolds once implanted in-vivo.
期刊介绍:
The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials.
The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.