The Relationship Between Retinal Nerve Fiber Thickness and Retinal Functional Sensitivity During Oct and Static Perimeter Examinations.

Q4 Medicine Ceska a Slovenska Oftalmologie Pub Date : 2024-01-01 DOI:10.31348/2024/43
Petr Veselý, Pavel Beneš, Jana Sokolová Šidlová, Petra Záděrová, Hana Došková
{"title":"The Relationship Between Retinal Nerve Fiber Thickness and Retinal Functional Sensitivity During Oct and Static Perimeter Examinations.","authors":"Petr Veselý, Pavel Beneš, Jana Sokolová Šidlová, Petra Záděrová, Hana Došková","doi":"10.31348/2024/43","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>To demonstrate the relationship of dependency between the thickness of the retinal nerve fiber layer and the functional sensitivity of the retina in healthy young individuals. We also secondarily investigated the relationship between refractive error and mean retinal thickness in the macula.</p><p><strong>Material and methods: </strong>The basic cohort contained 30 subjects with an average age of 23.4 ±4.2 years. These were young, generally healthy individuals without serious ocular pathologies. The average value of spherical equivalent in both eyes of all individuals was -1.2 ±2.5 D. We measured the thickness of the retinal nerve fiber layer (RNFL) in the papilla area and the average thickness of the retina in the area of the macula using the device OPKO Spectral OCT SLO Combination Imaging System (Opko Health, USA). We performed a functional examination of the retina within an area up to 30° using a perimeter with a stimulus with a Frequency Doubling Technology (FDT) from the company Humphrey (Carl Ziess Meditec, Inc., Dublin, CA). As a significant variable for comparison, we determined the mean value of retinal sensitivity deviation (MD).</p><p><strong>Results: </strong>In our study, we did not demonstrate a statistically significant relationship between the average thickness of the retinal nerve fiber layer (RNFL) and the average value of retinal functional sensitivity (r = 0.18, p = 0.34) in either right eyes or the left eyes of the examined subjects (r = 0.20, p = 0.29). We also did not find a statistically significant relationship secondarily between the variable called the spherical equivalent of refractive error (SE) and the average retinal thickness in the macula in either the right eyes (r = 0.34, p = 0.06) or the left eyes (r = 0.18, p = 0.32).</p><p><strong>Conclusion: </strong>When comparing the average thickness of the nerve fibers in the papilla with the help of OCT examination and the functional sensitivity of the retina measured on an FDT perimeter, we did not find a statistically significant dependence in the group of right eyes or in the group of left eyes. We also achieved a similar result when examining the interdependence of the variables of spherical equivalent of refractive error of the eye and the average thickness of the retina in the macula.</p>","PeriodicalId":39839,"journal":{"name":"Ceska a Slovenska Oftalmologie","volume":"80 Ahead of print","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceska a Slovenska Oftalmologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31348/2024/43","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: To demonstrate the relationship of dependency between the thickness of the retinal nerve fiber layer and the functional sensitivity of the retina in healthy young individuals. We also secondarily investigated the relationship between refractive error and mean retinal thickness in the macula.

Material and methods: The basic cohort contained 30 subjects with an average age of 23.4 ±4.2 years. These were young, generally healthy individuals without serious ocular pathologies. The average value of spherical equivalent in both eyes of all individuals was -1.2 ±2.5 D. We measured the thickness of the retinal nerve fiber layer (RNFL) in the papilla area and the average thickness of the retina in the area of the macula using the device OPKO Spectral OCT SLO Combination Imaging System (Opko Health, USA). We performed a functional examination of the retina within an area up to 30° using a perimeter with a stimulus with a Frequency Doubling Technology (FDT) from the company Humphrey (Carl Ziess Meditec, Inc., Dublin, CA). As a significant variable for comparison, we determined the mean value of retinal sensitivity deviation (MD).

Results: In our study, we did not demonstrate a statistically significant relationship between the average thickness of the retinal nerve fiber layer (RNFL) and the average value of retinal functional sensitivity (r = 0.18, p = 0.34) in either right eyes or the left eyes of the examined subjects (r = 0.20, p = 0.29). We also did not find a statistically significant relationship secondarily between the variable called the spherical equivalent of refractive error (SE) and the average retinal thickness in the macula in either the right eyes (r = 0.34, p = 0.06) or the left eyes (r = 0.18, p = 0.32).

Conclusion: When comparing the average thickness of the nerve fibers in the papilla with the help of OCT examination and the functional sensitivity of the retina measured on an FDT perimeter, we did not find a statistically significant dependence in the group of right eyes or in the group of left eyes. We also achieved a similar result when examining the interdependence of the variables of spherical equivalent of refractive error of the eye and the average thickness of the retina in the macula.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Oct和静态周界检查中视网膜神经纤维厚度与视网膜功能敏感性的关系。
目的:探讨健康青年视网膜神经纤维层厚度与视网膜功能敏感性之间的依赖关系。我们还研究了屈光不正与黄斑视网膜平均厚度之间的关系。材料与方法:基础队列30例,平均年龄23.4±4.2岁。这些人都是年轻人,总体健康,没有严重的眼部病变。所有患者双眼的平均球等效值为-1.2±2.5 d。我们使用OPKO光谱OCT SLO组合成像系统(OPKO Health, USA)测量了乳头区视网膜神经纤维层(RNFL)的厚度和黄斑区视网膜的平均厚度。我们使用Humphrey公司(Carl Ziess Meditec, Inc., Dublin, CA)的倍频技术(FDT)刺激,在30°范围内对视网膜进行了功能检查。作为比较的重要变量,我们确定了视网膜灵敏度偏差(MD)的平均值。结果:在我们的研究中,我们没有证明被检查对象的右眼或左眼视网膜神经纤维层(RNFL)的平均厚度与视网膜功能灵敏度平均值(r = 0.18, p = 0.34)之间存在统计学意义上的关系(r = 0.20, p = 0.29)。我们也没有发现在右眼(r = 0.34, p = 0.06)或左眼(r = 0.18, p = 0.32)中称为球面等效屈光不正(SE)的变量与黄斑视网膜平均厚度之间有统计学意义的次要关系。结论:将OCT检查下乳头神经纤维的平均厚度与FDT周长测量视网膜的功能敏感性进行比较,我们发现右眼组与左眼组之间没有统计学意义上的依赖性。我们也取得了类似的结果,当检查的相互依存的球形等效屈光不正的眼睛和平均厚度的视网膜黄斑的变量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ceska a Slovenska Oftalmologie
Ceska a Slovenska Oftalmologie Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
0
期刊介绍: - Redakce přijímá pouze práce vyhovující po odborné stránce, které jsou na odpovídající profesionální a formální úrovni. - Uveřejněná práce se stává majetkem časopisu, přetisknout její část nebo obrázek lze jen s citací původu. - Rukopis zasílejte v originále a dobře čitelné kopii (je nutná také kopie tabulek, legend, podle možnosti i obrázků). - Listy číslujte v pravém horním rohu a spojujte svorkou, nesešívejte. Přijímáme práce psané na jedné straně kvalitního bílého nelesklého papíru formátu A4 (neprůklepový) na psacím stroji nebo počítači s obvyklými typy.
期刊最新文献
Choroidal Thickness and Central Macular Thickness Measurements with Cirrus HD-OCT in Healthy Individuals in the Turkish Population Intravitreal Dexamethasone Implant in the Treatment of Diabetic Macular Edema Focusing on the Role of OCT Biomarkers Long-Term Refractive and Topographical Changes in Keratoconic Eyes after Accelerated Corneal Crosslinking. Surgical Treatment of Rhegmatogenous Retinal Detachment in the Only Seeing Eye. Easy Method of Pterygium Excision using Autologous Blood for Conjunctiva Autograft Fixation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1