Exchange-Biased Multiring Planar Hall Magnetoresistive Sensors With Nanotesla Resolution in Nonshielded Environments

IF 1.1 4区 物理与天体物理 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Magnetics Letters Pub Date : 2024-10-31 DOI:10.1109/LMAG.2024.3490380
J. Schmidtpeter;Proloy T. Das;Y. Zabila;C. Schubert;T. Gundrum;T. Wondrak;D. Makarov
{"title":"Exchange-Biased Multiring Planar Hall Magnetoresistive Sensors With Nanotesla Resolution in Nonshielded Environments","authors":"J. Schmidtpeter;Proloy T. Das;Y. Zabila;C. Schubert;T. Gundrum;T. Wondrak;D. Makarov","doi":"10.1109/LMAG.2024.3490380","DOIUrl":null,"url":null,"abstract":"Planar Hall magnetoresistive sensors (PHMRs) are promising candidates for various magnetic sensing applications due to their high sensitivity, low power consumption, and compatibility with integrated circuit technology. However, their performance is often limited by inherent noise sources, impacting their resolution and overall sensitivity. Here the effect of three bilayer structures NiFe(10 nm)/IrMn(10 nm), NiFe(30 nm)/IrMn(10 nm), and NiFe(30 nm)/IrMn(20 nm) on noise levels is investigated at low frequency (DC-25 Hz). This study includes a detailed investigation on the optimization process and noise characteristics of multiring PHMR sensors, focusing on identifying and quantifying the dominant noise sources. The experimental measurements are complemented by a theoretical analysis of noise sources including thermal noise, 1/\n<italic>f</i>\n noise, intermixing, and environmental noise. The best magnetic resolution is observed for the NiFe(30 nm)/IrMn(10 nm) structure, which achieves a detectivity below 1.5 nT/√Hz at 10 Hz in a nonshielded environment at room temperature. In addition, a substantial improvement in sensitivity is observed by annealing the sensors at 250 °C for 1 h. The findings of this study contribute to a deeper understanding of noise behavior in PHMR sensors, paving the way for developing strategies to improve their performance for demanding sensing applications at low frequencies.","PeriodicalId":13040,"journal":{"name":"IEEE Magnetics Letters","volume":"15 ","pages":"1-5"},"PeriodicalIF":1.1000,"publicationDate":"2024-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Magnetics Letters","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/10740679/","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Planar Hall magnetoresistive sensors (PHMRs) are promising candidates for various magnetic sensing applications due to their high sensitivity, low power consumption, and compatibility with integrated circuit technology. However, their performance is often limited by inherent noise sources, impacting their resolution and overall sensitivity. Here the effect of three bilayer structures NiFe(10 nm)/IrMn(10 nm), NiFe(30 nm)/IrMn(10 nm), and NiFe(30 nm)/IrMn(20 nm) on noise levels is investigated at low frequency (DC-25 Hz). This study includes a detailed investigation on the optimization process and noise characteristics of multiring PHMR sensors, focusing on identifying and quantifying the dominant noise sources. The experimental measurements are complemented by a theoretical analysis of noise sources including thermal noise, 1/ f noise, intermixing, and environmental noise. The best magnetic resolution is observed for the NiFe(30 nm)/IrMn(10 nm) structure, which achieves a detectivity below 1.5 nT/√Hz at 10 Hz in a nonshielded environment at room temperature. In addition, a substantial improvement in sensitivity is observed by annealing the sensors at 250 °C for 1 h. The findings of this study contribute to a deeper understanding of noise behavior in PHMR sensors, paving the way for developing strategies to improve their performance for demanding sensing applications at low frequencies.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非屏蔽环境下具有纳特斯拉分辨率的交换偏压多线平面霍尔磁阻传感器
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Magnetics Letters
IEEE Magnetics Letters PHYSICS, APPLIED-
CiteScore
2.40
自引率
0.00%
发文量
37
期刊介绍: IEEE Magnetics Letters is a peer-reviewed, archival journal covering the physics and engineering of magnetism, magnetic materials, applied magnetics, design and application of magnetic devices, bio-magnetics, magneto-electronics, and spin electronics. IEEE Magnetics Letters publishes short, scholarly articles of substantial current interest. IEEE Magnetics Letters is a hybrid Open Access (OA) journal. For a fee, authors have the option making their articles freely available to all, including non-subscribers. OA articles are identified as Open Access.
期刊最新文献
A New Differential Magnetic Probe With Out-of-Phase Balun and Differential Loops Exchange-Biased Multiring Planar Hall Magnetoresistive Sensors With Nanotesla Resolution in Nonshielded Environments Spintronic Neuron Using a Magnetic Tunnel Junction for Low-Power Neuromorphic Computing Relaxation Dynamics of Sputtered Fe80Co20 Thin Films on Different Substrates: Micromagnetic Validation Biaxially Stretchable Spin Valves With Stable Magnetic Sensing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1