{"title":"Comparative Evaluation of Microleakage below the Orthodontic Brackets after Bonding with Various Adhesive Agents: An <i>In Vitro</i> Study.","authors":"Shivani Singh, Brajendu, Irfanul Haque, Bilu S Kavanakudy, Mohamed Ht Parambil, Crystal R Soans","doi":"10.5005/jp-journals-10024-3696","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of the current study was to assess the microleakage below orthodontic brackets after bonding with three different adhesive materials.</p><p><strong>Materials and methods: </strong>In total, 75 healthy human premolars that had been extracted for orthodontic treatment were utilized in this investigation. The samples were divided into three groups of 25 samples randomly. Premolar brackets with stainless steel bondable 0.022 slot pre-adjusted edgewise appliances were utilized. Group I: Brackets bonded with Nanocomposite Filtek Z350 XT, group II: brackets bonded with Transbond XT, group III: brackets bonded with resin-reinforced glass ionomer cement-GC Fuji Ortho LC. A surveyor applied a 200 g weight to each bracket, making minor adjustments to ensure the adhesive thickness was consistent. Thermocycling was then carried out for 1000 cycles at 5 ± 2°C to 55 ± 2°C with a dwell time of 30 s and a transfer time of 5 s. The samples were incubated in a 0.5% basic fuchsine solution for a day. Every sample was inspected using a stereomicroscope with a ×16 magnification. The data were collected and analyzed.</p><p><strong>Results: </strong>The least microleakage was found in Transbond XT adhesive group (1.84 ± 0.12), followed by Filtek Z350 XT (1.96 ± 0.08) and GC Fuji Ortho LC (2.44 ± 0.10) group. There was a highly significant difference between the different adhesive agent groups. There was a statistically significant difference found between Filtek Z350 XT vs GC Fuji Ortho LC and Transbond XT vs GC Fuji Ortho LC with a mean difference of -0.48 and 0.60, respectively. However, there was no significant difference between Filtek Z350 XT vs Transbond XT with a mean difference of 0.12.</p><p><strong>Conclusion: </strong>Within the limitation, the present study concluded that the Transbond XT showed better adhesive properties and least microleakage compared with Filtek Z350 XT and GC Fuji Ortho LC.</p><p><strong>Clinical significance: </strong>There are many undesirable side effects of orthodontic therapy, including cavities, demineralization, and discoloration of the enamel. Unpleasant \"white-spot lesions\" or secondary caries under and around the brackets can result from microleakage between the adhesive and the base of the orthodontic bracket as well as between the adhesive and the enamel. How to cite this article: Singh S, Brajendu, Haque I, et al. Comparative Evaluation of Microleakage below the Orthodontic Brackets after Bonding with Various Adhesive Agents: An <i>In Vitro</i> Study. J Contemp Dent Pract 2024;25(8):722-725.</p>","PeriodicalId":35792,"journal":{"name":"Journal of Contemporary Dental Practice","volume":"25 8","pages":"722-725"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Dental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10024-3696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim of the current study was to assess the microleakage below orthodontic brackets after bonding with three different adhesive materials.

Materials and methods: In total, 75 healthy human premolars that had been extracted for orthodontic treatment were utilized in this investigation. The samples were divided into three groups of 25 samples randomly. Premolar brackets with stainless steel bondable 0.022 slot pre-adjusted edgewise appliances were utilized. Group I: Brackets bonded with Nanocomposite Filtek Z350 XT, group II: brackets bonded with Transbond XT, group III: brackets bonded with resin-reinforced glass ionomer cement-GC Fuji Ortho LC. A surveyor applied a 200 g weight to each bracket, making minor adjustments to ensure the adhesive thickness was consistent. Thermocycling was then carried out for 1000 cycles at 5 ± 2°C to 55 ± 2°C with a dwell time of 30 s and a transfer time of 5 s. The samples were incubated in a 0.5% basic fuchsine solution for a day. Every sample was inspected using a stereomicroscope with a ×16 magnification. The data were collected and analyzed.

Results: The least microleakage was found in Transbond XT adhesive group (1.84 ± 0.12), followed by Filtek Z350 XT (1.96 ± 0.08) and GC Fuji Ortho LC (2.44 ± 0.10) group. There was a highly significant difference between the different adhesive agent groups. There was a statistically significant difference found between Filtek Z350 XT vs GC Fuji Ortho LC and Transbond XT vs GC Fuji Ortho LC with a mean difference of -0.48 and 0.60, respectively. However, there was no significant difference between Filtek Z350 XT vs Transbond XT with a mean difference of 0.12.

Conclusion: Within the limitation, the present study concluded that the Transbond XT showed better adhesive properties and least microleakage compared with Filtek Z350 XT and GC Fuji Ortho LC.

Clinical significance: There are many undesirable side effects of orthodontic therapy, including cavities, demineralization, and discoloration of the enamel. Unpleasant "white-spot lesions" or secondary caries under and around the brackets can result from microleakage between the adhesive and the base of the orthodontic bracket as well as between the adhesive and the enamel. How to cite this article: Singh S, Brajendu, Haque I, et al. Comparative Evaluation of Microleakage below the Orthodontic Brackets after Bonding with Various Adhesive Agents: An In Vitro Study. J Contemp Dent Pract 2024;25(8):722-725.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Contemporary Dental Practice
Journal of Contemporary Dental Practice Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
174
期刊介绍: The Journal of Contemporary Dental Practice (JCDP), is a peer-reviewed, open access MEDLINE indexed journal. The journal’s full text is available online at http://www.thejcdp.com. The journal allows free access (open access) to its contents. Articles with clinical relevance will be given preference for publication. The Journal publishes original research papers, review articles, rare and novel case reports, and clinical techniques. Manuscripts are invited from all specialties of dentistry i.e., conservative dentistry and endodontics, dentofacial orthopedics and orthodontics, oral medicine and radiology, oral pathology, oral surgery, orodental diseases, pediatric dentistry, implantology, periodontics, clinical aspects of public health dentistry, and prosthodontics.
期刊最新文献
Internal Fit and Marginal Adaptation of Posterior CAD/CAM Crowns Fabricated from Fully Crystallized Lithium Disilicate Compared to Partially Crystallized Lithium Disilicate with Two Finish Line Thicknesses: An In Vitro Study. Management of Deep Caries Lesions: A Study among Dentists in the Private Sector of Casablanca, Morocco. One-year Clinical Evaluation, Patient Satisfaction, and Adaptation of Milled (PEEK) Single Anterior Crowns Veneered with Two Different Techniques. Patient Satisfaction during Upper Lip Augmentation Procedures: V-Y in V-Y Technique Compared to Micro-fat Injection: A Randomized Clinical Trial. Trends, Collaborative Networks, and Impact of Infrared Thermography and Thermal Therapies in Dentistry: A Bibliometric Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1