Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers.

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Review of Scientific Instruments Pub Date : 2024-12-01 DOI:10.1063/5.0224783
N Schoonheere, C Reux, H Meister, P Beyer, P Carvalho, I Coffey, K Lawson, P Puglia, U Sheikh
{"title":"Spurious radiated power signal following massive material injections in JET and the effect of neutral gas pressure on resistive bolometers.","authors":"N Schoonheere, C Reux, H Meister, P Beyer, P Carvalho, I Coffey, K Lawson, P Puglia, U Sheikh","doi":"10.1063/5.0224783","DOIUrl":null,"url":null,"abstract":"<p><p>Massive material injections in the JET tokamak have been observed to substantially affect resistive bolometer measurements, resulting in a spurious radiated power signal proportional to the quantity injected and reaching up to 8 MW. These bolometers are calibrated and designed to operate in near vacuum but certain scenarios requiring large gas injections can push the neutral pressure past nominal values. This study demonstrates that the bolometry measurement can be affected at neutral pressures above 0.1 Pa following injections with standard gas valves, shattered pellet injections, and particularly massive gas injections. The power measurement of resistive bolometers is based on the temperature difference between a measurement sensor exposed to radiation and a shielded reference sensor. We employ a thermal conductivity model to demonstrate that the conduction through the gas and the distinct geometries between the sensors can affect their cooling efficiency. This additional cooling pathway, coupled with the Joule heating from the applied voltage causes the equilibrium temperatures of the sensors to diverge. Being the very basis of the measure, this temperature difference induces a signal that is erroneously interpreted as radiated power. Experiments show large discrepancies in the response to neutral pressure among bolometer channels, attributed to variations in channel physical parameters. Nonetheless, the modeled total radiated power reproduces the experimental measurements within an order of magnitude, affirming the sensitivity of resistive bolometers to neutral pressure and gas species.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"95 12","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0224783","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Massive material injections in the JET tokamak have been observed to substantially affect resistive bolometer measurements, resulting in a spurious radiated power signal proportional to the quantity injected and reaching up to 8 MW. These bolometers are calibrated and designed to operate in near vacuum but certain scenarios requiring large gas injections can push the neutral pressure past nominal values. This study demonstrates that the bolometry measurement can be affected at neutral pressures above 0.1 Pa following injections with standard gas valves, shattered pellet injections, and particularly massive gas injections. The power measurement of resistive bolometers is based on the temperature difference between a measurement sensor exposed to radiation and a shielded reference sensor. We employ a thermal conductivity model to demonstrate that the conduction through the gas and the distinct geometries between the sensors can affect their cooling efficiency. This additional cooling pathway, coupled with the Joule heating from the applied voltage causes the equilibrium temperatures of the sensors to diverge. Being the very basis of the measure, this temperature difference induces a signal that is erroneously interpreted as radiated power. Experiments show large discrepancies in the response to neutral pressure among bolometer channels, attributed to variations in channel physical parameters. Nonetheless, the modeled total radiated power reproduces the experimental measurements within an order of magnitude, affirming the sensitivity of resistive bolometers to neutral pressure and gas species.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
期刊最新文献
A simple graphics processing unit-accelerated propagation routine for laser pulses in the strong-field regime. Analyzing the effects of reflections on optical diagnostics in the main chamber and divertor of WEST (invited). Application of tunneling magnetoresistance in electromagnetic tomography system construction. Combined Raman spectroscopy and electrical transport measurements in ultra-high vacuum down to 3.7 K. Design of a novel high-speed tensile method for testing the high strain rate tensile behavior of aluminum alloys.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1