Accuracy of leg length changes in total hip arthroplasty using a computed tomography-based augmented reality navigation system

IF 2 3区 医学 Q2 ORTHOPEDICS Archives of Orthopaedic and Trauma Surgery Pub Date : 2024-12-12 DOI:10.1007/s00402-024-05705-8
Gai Kobayashi, Shintaro Ichikawa, Shine Tone, Yohei Naito, Akihiro Sudo, Masahiro Hasegawa
{"title":"Accuracy of leg length changes in total hip arthroplasty using a computed tomography-based augmented reality navigation system","authors":"Gai Kobayashi,&nbsp;Shintaro Ichikawa,&nbsp;Shine Tone,&nbsp;Yohei Naito,&nbsp;Akihiro Sudo,&nbsp;Masahiro Hasegawa","doi":"10.1007/s00402-024-05705-8","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Leg length is an important consideration in total hip arthroplasty (THA) as leg length discrepancies (LLD) after THA cause poor outcomes and medical litigation. This study aimed to investigate the accuracy of computed tomography (CT)-based navigation with augmented reality (AR) technology for measuring intra-operative leg length change using anteroposterior radiography (two-dimensional, 2D) and CT (three-dimensional, 3D).</p><h3>Materials and methods</h3><p>This study included 71 patients (75 hips) who underwent primary cementless THA in the supine position between June 2022 and November 2023 using the HoloNavi One. To assess the accuracy of the HoloNavi One based on 2D and 3D measurements, the absolute error between the intra-operative leg length change and the 2D and 3D measurements was evaluated, and the correlations were investigated. Additionally, factors affecting the absolute error were examined using multivariate analysis.</p><h3>Results</h3><p>The mean intra-operative leg length change when using the HoloNavi One was 6.5 ± 5.0 mm, while the mean leg length change on the 2D and 3D measurements were 5.9 ± 4.8 mm and 4.6 ± 5.7 mm, respectively. The mean absolute errors were 2.3 ± 2.7 mm between the HoloNavi One and 2D measurements, and 3.8 ± 3.3 mm between HoloNavi One and 3D measurements. The absolute errors in leg length changes for the 3D measurements were greater than those for the 2D measurements (p &lt; 0.01). Positive correlations of leg length changes were found between the HoloNavi One and the 2D and 3D measurements. In the multiple regression analysis, no significant factors affecting the absolute error were identified in either the 2D or 3D measurements.</p><h3>Conclusions</h3><p>CT-based navigation with AR technology in the supine position provided acceptable accuracy for leg length change measurements.</p></div>","PeriodicalId":8326,"journal":{"name":"Archives of Orthopaedic and Trauma Surgery","volume":"145 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Orthopaedic and Trauma Surgery","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s00402-024-05705-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Leg length is an important consideration in total hip arthroplasty (THA) as leg length discrepancies (LLD) after THA cause poor outcomes and medical litigation. This study aimed to investigate the accuracy of computed tomography (CT)-based navigation with augmented reality (AR) technology for measuring intra-operative leg length change using anteroposterior radiography (two-dimensional, 2D) and CT (three-dimensional, 3D).

Materials and methods

This study included 71 patients (75 hips) who underwent primary cementless THA in the supine position between June 2022 and November 2023 using the HoloNavi One. To assess the accuracy of the HoloNavi One based on 2D and 3D measurements, the absolute error between the intra-operative leg length change and the 2D and 3D measurements was evaluated, and the correlations were investigated. Additionally, factors affecting the absolute error were examined using multivariate analysis.

Results

The mean intra-operative leg length change when using the HoloNavi One was 6.5 ± 5.0 mm, while the mean leg length change on the 2D and 3D measurements were 5.9 ± 4.8 mm and 4.6 ± 5.7 mm, respectively. The mean absolute errors were 2.3 ± 2.7 mm between the HoloNavi One and 2D measurements, and 3.8 ± 3.3 mm between HoloNavi One and 3D measurements. The absolute errors in leg length changes for the 3D measurements were greater than those for the 2D measurements (p < 0.01). Positive correlations of leg length changes were found between the HoloNavi One and the 2D and 3D measurements. In the multiple regression analysis, no significant factors affecting the absolute error were identified in either the 2D or 3D measurements.

Conclusions

CT-based navigation with AR technology in the supine position provided acceptable accuracy for leg length change measurements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.30
自引率
13.00%
发文量
424
审稿时长
2 months
期刊介绍: "Archives of Orthopaedic and Trauma Surgery" is a rich source of instruction and information for physicians in clinical practice and research in the extensive field of orthopaedics and traumatology. The journal publishes papers that deal with diseases and injuries of the musculoskeletal system from all fields and aspects of medicine. The journal is particularly interested in papers that satisfy the information needs of orthopaedic clinicians and practitioners. The journal places special emphasis on clinical relevance. "Archives of Orthopaedic and Trauma Surgery" is the official journal of the German Speaking Arthroscopy Association (AGA).
期刊最新文献
Bipolar vs. monopolar sealer in decreasing blood loss and transfusion rate in patients undergoing two-stage exchange in infected total knee arthroplasty: propensity score-matched study. Clinical and magnetic resonance imaging outcome after proximal hamstring tendon repair at mean 3 years follow-up. Scapho-metacarpal dual mobility prosthesis for TMC-1 joint salvage: technical insights. The single antegrade sling graft: a novel hamstring autograft technique for combined anterior cruciate ligament and anterolateral ligament reconstruction. Total joint arthroplasty of the thumb CMC joint.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1