{"title":"Accuracy of leg length changes in total hip arthroplasty using a computed tomography-based augmented reality navigation system","authors":"Gai Kobayashi, Shintaro Ichikawa, Shine Tone, Yohei Naito, Akihiro Sudo, Masahiro Hasegawa","doi":"10.1007/s00402-024-05705-8","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Leg length is an important consideration in total hip arthroplasty (THA) as leg length discrepancies (LLD) after THA cause poor outcomes and medical litigation. This study aimed to investigate the accuracy of computed tomography (CT)-based navigation with augmented reality (AR) technology for measuring intra-operative leg length change using anteroposterior radiography (two-dimensional, 2D) and CT (three-dimensional, 3D).</p><h3>Materials and methods</h3><p>This study included 71 patients (75 hips) who underwent primary cementless THA in the supine position between June 2022 and November 2023 using the HoloNavi One. To assess the accuracy of the HoloNavi One based on 2D and 3D measurements, the absolute error between the intra-operative leg length change and the 2D and 3D measurements was evaluated, and the correlations were investigated. Additionally, factors affecting the absolute error were examined using multivariate analysis.</p><h3>Results</h3><p>The mean intra-operative leg length change when using the HoloNavi One was 6.5 ± 5.0 mm, while the mean leg length change on the 2D and 3D measurements were 5.9 ± 4.8 mm and 4.6 ± 5.7 mm, respectively. The mean absolute errors were 2.3 ± 2.7 mm between the HoloNavi One and 2D measurements, and 3.8 ± 3.3 mm between HoloNavi One and 3D measurements. The absolute errors in leg length changes for the 3D measurements were greater than those for the 2D measurements (p < 0.01). Positive correlations of leg length changes were found between the HoloNavi One and the 2D and 3D measurements. In the multiple regression analysis, no significant factors affecting the absolute error were identified in either the 2D or 3D measurements.</p><h3>Conclusions</h3><p>CT-based navigation with AR technology in the supine position provided acceptable accuracy for leg length change measurements.</p></div>","PeriodicalId":8326,"journal":{"name":"Archives of Orthopaedic and Trauma Surgery","volume":"145 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Orthopaedic and Trauma Surgery","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s00402-024-05705-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Leg length is an important consideration in total hip arthroplasty (THA) as leg length discrepancies (LLD) after THA cause poor outcomes and medical litigation. This study aimed to investigate the accuracy of computed tomography (CT)-based navigation with augmented reality (AR) technology for measuring intra-operative leg length change using anteroposterior radiography (two-dimensional, 2D) and CT (three-dimensional, 3D).
Materials and methods
This study included 71 patients (75 hips) who underwent primary cementless THA in the supine position between June 2022 and November 2023 using the HoloNavi One. To assess the accuracy of the HoloNavi One based on 2D and 3D measurements, the absolute error between the intra-operative leg length change and the 2D and 3D measurements was evaluated, and the correlations were investigated. Additionally, factors affecting the absolute error were examined using multivariate analysis.
Results
The mean intra-operative leg length change when using the HoloNavi One was 6.5 ± 5.0 mm, while the mean leg length change on the 2D and 3D measurements were 5.9 ± 4.8 mm and 4.6 ± 5.7 mm, respectively. The mean absolute errors were 2.3 ± 2.7 mm between the HoloNavi One and 2D measurements, and 3.8 ± 3.3 mm between HoloNavi One and 3D measurements. The absolute errors in leg length changes for the 3D measurements were greater than those for the 2D measurements (p < 0.01). Positive correlations of leg length changes were found between the HoloNavi One and the 2D and 3D measurements. In the multiple regression analysis, no significant factors affecting the absolute error were identified in either the 2D or 3D measurements.
Conclusions
CT-based navigation with AR technology in the supine position provided acceptable accuracy for leg length change measurements.
期刊介绍:
"Archives of Orthopaedic and Trauma Surgery" is a rich source of instruction and information for physicians in clinical practice and research in the extensive field of orthopaedics and traumatology. The journal publishes papers that deal with diseases and injuries of the musculoskeletal system from all fields and aspects of medicine. The journal is particularly interested in papers that satisfy the information needs of orthopaedic clinicians and practitioners. The journal places special emphasis on clinical relevance.