{"title":"Coordinated Feedback Power Control Method for Hybrid Multi-Infeed HVDC System","authors":"Jiachen Zhang;Qi Xie;Zixuan Zheng;Chunyi Guo;Yi Zou;Jie Ren","doi":"10.35833/MPCE.2023.000586","DOIUrl":null,"url":null,"abstract":"During the power modulation process of line commutated converter-based high-voltage direct current (LCC-HVDC), the transient power mismatch between the fast-change converter station and the slow-response reactive power compensators (RPCs) can cause transient voltage disturbances at the weak sending end of the AC grid. To mitigate such voltage disturbances, this paper proposes a coordinated feedback power control method for the hybrid multi-infeed HVDC (HMI-HVDC) system comprising an LCC-HVDC and voltage source converter-based HVDC (VSC-HVDC) systems. The mechanism of the disturbance caused by transient power mismatch is quantitatively analyzed, and the numerical relationship between the instantaneous unbalanced power and the AC voltage is derived. Based on the numerical relationship and considering the time-varying relationship of reactive power between converter stations, the unbalanced power is set as the feedback and coordinately distributed among the inverter stations of VSC-HVDC, and the rectifier and the inverter stations of LCC-HVDC. Simulation results verify that the proposed method can effectively suppress voltage disturbance without relying on remote communication, thus enhancing the operation performance of the HMI-HVDC system.","PeriodicalId":51326,"journal":{"name":"Journal of Modern Power Systems and Clean Energy","volume":"12 6","pages":"2045-2057"},"PeriodicalIF":5.7000,"publicationDate":"2024-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10520022","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Modern Power Systems and Clean Energy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10520022/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

During the power modulation process of line commutated converter-based high-voltage direct current (LCC-HVDC), the transient power mismatch between the fast-change converter station and the slow-response reactive power compensators (RPCs) can cause transient voltage disturbances at the weak sending end of the AC grid. To mitigate such voltage disturbances, this paper proposes a coordinated feedback power control method for the hybrid multi-infeed HVDC (HMI-HVDC) system comprising an LCC-HVDC and voltage source converter-based HVDC (VSC-HVDC) systems. The mechanism of the disturbance caused by transient power mismatch is quantitatively analyzed, and the numerical relationship between the instantaneous unbalanced power and the AC voltage is derived. Based on the numerical relationship and considering the time-varying relationship of reactive power between converter stations, the unbalanced power is set as the feedback and coordinately distributed among the inverter stations of VSC-HVDC, and the rectifier and the inverter stations of LCC-HVDC. Simulation results verify that the proposed method can effectively suppress voltage disturbance without relying on remote communication, thus enhancing the operation performance of the HMI-HVDC system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
混合多馈直流系统的协调反馈功率控制方法
在基于线路换向变流器的高压直流(lc - hvdc)功率调制过程中,快速变化换流站与慢响应无功补偿器之间的暂态功率失配会导致交流电网弱发送端的暂态电压扰动。为了减轻这种电压干扰,本文提出了一种由lc -HVDC和基于电压源变换器的HVDC (vcs -HVDC)组成的混合多馈入HVDC (HMI-HVDC)系统的协调反馈功率控制方法。定量分析了暂态功率失配引起扰动的机理,推导了暂态不平衡功率与交流电压之间的数值关系。基于数值关系,考虑换流站间无功功率的时变关系,将不平衡功率设置为反馈,并在VSC-HVDC的逆变站、LCC-HVDC的整流站和逆变站之间进行协调分布。仿真结果表明,该方法可以有效抑制电压干扰,而无需依赖远程通信,从而提高人机直流系统的运行性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Modern Power Systems and Clean Energy
Journal of Modern Power Systems and Clean Energy ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
12.30
自引率
14.30%
发文量
97
审稿时长
13 weeks
期刊介绍: Journal of Modern Power Systems and Clean Energy (MPCE), commencing from June, 2013, is a newly established, peer-reviewed and quarterly published journal in English. It is the first international power engineering journal originated in mainland China. MPCE publishes original papers, short letters and review articles in the field of modern power systems with focus on smart grid technology and renewable energy integration, etc.
期刊最新文献
Power Switching Based on Trajectory Planning and Sliding Mode Control for Solid Oxide Fuel Cell Systems Contents Contents Resonance Assessment of Large-scale Wind Park Connected to Primary Distribution Network Simulation-Based Approach to Assessing Short-Term Power Variations of PV Power Plants Under Cloud Conditions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1