PCF-based multi-analyte refractive index sensor for pathogen detection in water

IF 2.2 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Journal of Computational Electronics Pub Date : 2024-12-18 DOI:10.1007/s10825-024-02239-5
Mahia Rukhsana Deepti, Md. Aslam Mollah
{"title":"PCF-based multi-analyte refractive index sensor for pathogen detection in water","authors":"Mahia Rukhsana Deepti,&nbsp;Md. Aslam Mollah","doi":"10.1007/s10825-024-02239-5","DOIUrl":null,"url":null,"abstract":"<div><p>A photonic crystal fiber (PCF)-based multi-analyte refractive index sensor is introduced in this study for the detection of four waterborne pathogens: <i>Vibrio cholerae</i>, <i>Bacillus anthracis</i>, <i>Escherichia coli</i>, and <i>Enterococcus faecalis</i>. The sensor comprises a tri-core structure with hexagonal rings encased in a silica substrate. Two selective holes are infused with water samples, enabling concurrent detection of two analytes. The sensor integrates liquid-silica mode coupling as its sensing mechanism. The couplings are precisely estimated and numerically evaluated using a finite-element method (FEM)-based simulation tool. The optimization of the sensor’s structural characteristics resulted in wavelength sensitivity of 6386 nm/RIU, 7104 nm/RIU, 8510 nm/RIU, and 3409 nm/RIU for sample pairs of <i>V. cholerae</i>–pure water, <i>V. cholerae</i>–<i>V. cholerae</i>, <i>V. cholerae</i>–<i>B. anthracis</i>, and <i>E. coli</i>–<i>V. cholerae</i>, respectively. Furthermore, the sensor exhibits the highest wavelength resolution of <span>\\(\\text {1.59} \\times \\text {10}^{-5}\\)</span> RIU and figure of merit of 142 <span>\\(\\text {RIU}^{-1}\\)</span> and is also assessed for detection limit, detection accuracy, and signal-to-noise ratio. Featuring a straightforward design and remarkable sensing capabilities, the proposed sensor is anticipated to be exceptionally effective at detecting waterborne pathogens, with potential to excel in identifying chemicals, biomedical substances, and other diverse analytes.</p></div>","PeriodicalId":620,"journal":{"name":"Journal of Computational Electronics","volume":"24 1","pages":""},"PeriodicalIF":2.2000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computational Electronics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10825-024-02239-5","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

A photonic crystal fiber (PCF)-based multi-analyte refractive index sensor is introduced in this study for the detection of four waterborne pathogens: Vibrio cholerae, Bacillus anthracis, Escherichia coli, and Enterococcus faecalis. The sensor comprises a tri-core structure with hexagonal rings encased in a silica substrate. Two selective holes are infused with water samples, enabling concurrent detection of two analytes. The sensor integrates liquid-silica mode coupling as its sensing mechanism. The couplings are precisely estimated and numerically evaluated using a finite-element method (FEM)-based simulation tool. The optimization of the sensor’s structural characteristics resulted in wavelength sensitivity of 6386 nm/RIU, 7104 nm/RIU, 8510 nm/RIU, and 3409 nm/RIU for sample pairs of V. cholerae–pure water, V. choleraeV. cholerae, V. choleraeB. anthracis, and E. coliV. cholerae, respectively. Furthermore, the sensor exhibits the highest wavelength resolution of \(\text {1.59} \times \text {10}^{-5}\) RIU and figure of merit of 142 \(\text {RIU}^{-1}\) and is also assessed for detection limit, detection accuracy, and signal-to-noise ratio. Featuring a straightforward design and remarkable sensing capabilities, the proposed sensor is anticipated to be exceptionally effective at detecting waterborne pathogens, with potential to excel in identifying chemicals, biomedical substances, and other diverse analytes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Computational Electronics
Journal of Computational Electronics ENGINEERING, ELECTRICAL & ELECTRONIC-PHYSICS, APPLIED
CiteScore
4.50
自引率
4.80%
发文量
142
审稿时长
>12 weeks
期刊介绍: he Journal of Computational Electronics brings together research on all aspects of modeling and simulation of modern electronics. This includes optical, electronic, mechanical, and quantum mechanical aspects, as well as research on the underlying mathematical algorithms and computational details. The related areas of energy conversion/storage and of molecular and biological systems, in which the thrust is on the charge transport, electronic, mechanical, and optical properties, are also covered. In particular, we encourage manuscripts dealing with device simulation; with optical and optoelectronic systems and photonics; with energy storage (e.g. batteries, fuel cells) and harvesting (e.g. photovoltaic), with simulation of circuits, VLSI layout, logic and architecture (based on, for example, CMOS devices, quantum-cellular automata, QBITs, or single-electron transistors); with electromagnetic simulations (such as microwave electronics and components); or with molecular and biological systems. However, in all these cases, the submitted manuscripts should explicitly address the electronic properties of the relevant systems, materials, or devices and/or present novel contributions to the physical models, computational strategies, or numerical algorithms.
期刊最新文献
Unraveling the resonant frequency of H-shaped microstrip antennas using a deep learning approach Impact of geometrical parameters on AlGaN/GaN heterostructure MOS-HEMT biosensor PCF-based multi-analyte refractive index sensor for pathogen detection in water Dual- and triple-absorber solar cell architecture achieves significant efficiency improvements Shallow donor impurity states in wurtzite InGaN/GaN coupled quantum wells under built-in electric field, hydrostatic pressure, and strain effects
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1