The Median Nerve Displays Adaptive Characteristics When Exposed to Repeated Pinch Grip Efforts of Varying Rates of Force Development: An Ultrasonic Investigation.

IF 2.1 4区 医学 Q2 ACOUSTICS Journal of Ultrasound in Medicine Pub Date : 2024-12-18 DOI:10.1002/jum.16634
Denise Balogh, Aaron M Kociolek
{"title":"The Median Nerve Displays Adaptive Characteristics When Exposed to Repeated Pinch Grip Efforts of Varying Rates of Force Development: An Ultrasonic Investigation.","authors":"Denise Balogh, Aaron M Kociolek","doi":"10.1002/jum.16634","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Repeated gripping with high grip forces and high rates of grip force development are risk factors for carpal tunnel syndrome. As the nerve's adaptive ability is crucial to prevent disease progression, we investigated how these risk factors influence median nerve deformation and displacement over the time course of a repeated pinch grip task.</p><p><strong>Methods: </strong>Seventeen healthy participants performed a repeated grip task against a load cell while their carpal tunnel was scanned with ultrasound. The grip task involved pulp-pinching three consecutive times from 0 to 40% maximal voluntary exertion (MVE), performed at three different rates of force development (RFD): 40% MVE/1 second; 2 seconds; and 5 seconds. Ultrasound images were analyzed at 10% MVE intervals. Nerve circularity, width, height, and cross-sectional area were measured to assess deformation. Median nerve displacement was assessed by its change in position relative to the flexor digitorum superficialis tendon of the third digit (FD) in both radioulnar and palmodorsal axes.</p><p><strong>Results: </strong>Linear mixed modeling indicated that median nerve deformation increased, becoming more circular, with each repeated pulp-pinch (P < .01) and with grip force magnitude (P < .01). However, a faster RFD decreased nerve deformation (P < .01). Furthermore, the nerve displaced ulnarly during pulp-pinching, with greater displacement during the fastest (ie, 40% MVE/1 second) RFD (P < .01).</p><p><strong>Conclusions: </strong>The median nerve deformed and displaced in response to pulp-pinching; however, faster rates of force development hindered this adaptive response. This likely reflects the viscoelastic properties of the healthy nerve and subsynovial connective tissue, highlighting the importance of tissue compliance in preventing nerve compression.</p>","PeriodicalId":17563,"journal":{"name":"Journal of Ultrasound in Medicine","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jum.16634","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Repeated gripping with high grip forces and high rates of grip force development are risk factors for carpal tunnel syndrome. As the nerve's adaptive ability is crucial to prevent disease progression, we investigated how these risk factors influence median nerve deformation and displacement over the time course of a repeated pinch grip task.

Methods: Seventeen healthy participants performed a repeated grip task against a load cell while their carpal tunnel was scanned with ultrasound. The grip task involved pulp-pinching three consecutive times from 0 to 40% maximal voluntary exertion (MVE), performed at three different rates of force development (RFD): 40% MVE/1 second; 2 seconds; and 5 seconds. Ultrasound images were analyzed at 10% MVE intervals. Nerve circularity, width, height, and cross-sectional area were measured to assess deformation. Median nerve displacement was assessed by its change in position relative to the flexor digitorum superficialis tendon of the third digit (FD) in both radioulnar and palmodorsal axes.

Results: Linear mixed modeling indicated that median nerve deformation increased, becoming more circular, with each repeated pulp-pinch (P < .01) and with grip force magnitude (P < .01). However, a faster RFD decreased nerve deformation (P < .01). Furthermore, the nerve displaced ulnarly during pulp-pinching, with greater displacement during the fastest (ie, 40% MVE/1 second) RFD (P < .01).

Conclusions: The median nerve deformed and displaced in response to pulp-pinching; however, faster rates of force development hindered this adaptive response. This likely reflects the viscoelastic properties of the healthy nerve and subsynovial connective tissue, highlighting the importance of tissue compliance in preventing nerve compression.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
4.30%
发文量
205
审稿时长
1.5 months
期刊介绍: The Journal of Ultrasound in Medicine (JUM) is dedicated to the rapid, accurate publication of original articles dealing with all aspects of medical ultrasound, particularly its direct application to patient care but also relevant basic science, advances in instrumentation, and biological effects. The journal is an official publication of the American Institute of Ultrasound in Medicine and publishes articles in a variety of categories, including Original Research papers, Review Articles, Pictorial Essays, Technical Innovations, Case Series, Letters to the Editor, and more, from an international bevy of countries in a continual effort to showcase and promote advances in the ultrasound community. Represented through these efforts are a wide variety of disciplines of ultrasound, including, but not limited to: -Basic Science- Breast Ultrasound- Contrast-Enhanced Ultrasound- Dermatology- Echocardiography- Elastography- Emergency Medicine- Fetal Echocardiography- Gastrointestinal Ultrasound- General and Abdominal Ultrasound- Genitourinary Ultrasound- Gynecologic Ultrasound- Head and Neck Ultrasound- High Frequency Clinical and Preclinical Imaging- Interventional-Intraoperative Ultrasound- Musculoskeletal Ultrasound- Neurosonology- Obstetric Ultrasound- Ophthalmologic Ultrasound- Pediatric Ultrasound- Point-of-Care Ultrasound- Public Policy- Superficial Structures- Therapeutic Ultrasound- Ultrasound Education- Ultrasound in Global Health- Urologic Ultrasound- Vascular Ultrasound
期刊最新文献
The Median Nerve Displays Adaptive Characteristics When Exposed to Repeated Pinch Grip Efforts of Varying Rates of Force Development: An Ultrasonic Investigation. Ultrasound Pattern of Congenital Smooth Muscle Hamartoma of the Skin. Ultrasonographic Features of the Fallopian Tubes: An Overview on Main Tubal Pathologies. Clinical and Multimodal Imaging Features of Hepatic Inflammatory Pseudotumors: A Two-Center Retrospective Study. Sonographic Characterization of Red-Blue Neurofibromas in Patients With Neurofibromatosis Type 1: An Observational Prospective Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1