[Characteristics of posterior coronal banana-shaped fragments and its research progress in treatment of intertrochanteric femoral fracture with cephalomedullary nail].

Haotao Li, Liwen Li, Shimin Chang
{"title":"[Characteristics of posterior coronal banana-shaped fragments and its research progress in treatment of intertrochanteric femoral fracture with cephalomedullary nail].","authors":"Haotao Li, Liwen Li, Shimin Chang","doi":"10.7507/1002-1892.202408068","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To summarize the characteristics of posterior coronal banana-shaped fragments and its research progress in treatment of intertrochanteric femoral fracture with cephalomedullary nail, provide valuable reference for clinical practice.</p><p><strong>Methods: </strong>Relevant domestic and foreign literature was extensively reviewed to summarize the history, anatomical structure of posterior coronal banana-shaped fragments, and the need for reduction and fixation, the influence on the stability of cephalomedullary nail, and the remedies.</p><p><strong>Results: </strong>The posterior coronal banana-shaped fragments refers to the second level fracture line of the intertrochanteric femoral fracture, involving four anatomical structures, namely, the posterior part of the greater trochanter, the intertrochanteric crest, the lesser trochanter, and the posteromedial cortex. With the wide application of three-dimensional-CT in clinical practice, the posterior coronal banana-shaped fragments were more comprehensively understood. According to whether the anterior extension of the fracture line affects the integrity of the lateral entry of the head and neck implant, the posterior coronal banana-shaped fragments can be divided into small and large ones, of which the large single banana-shaped fragment account for about 20% of the AO/Orthopaedic Trauma Association (AO/OTA) type A2 fractures. If the large fragment involving the posteromedial wall (lesser trochanter) will increase the difficulty of the medial cortical contact reduction; or involving the posterolateral wall and resulting in rupture of the entry portal (type A2.4), which will cause sagittal swing of the nail in the femoral marrow cavity, thereby affecting the stability of the nail. There is no effective technique for reduction and fixation of the banana-shaped fragment nowadays. However, the adverse effects of posterior coronal banana-shaped fragment can be compensated by improving the quality of fracture reduction and choosing high filling cephalomedullary nail.</p><p><strong>Conclusion: </strong>The posterior coronal banana-shaped fragments can easily lead to the rupture of the entry portal of head-neck implants, cause the sagittal swing of the cephalomedulis nail, and then lead to the loss of fracture reduction and affect the treatment effect. Whether the entry portal rupture or not and its risk factors still need further clinical and basic research.</p>","PeriodicalId":23979,"journal":{"name":"中国修复重建外科杂志","volume":"38 12","pages":"1517-1523"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11655376/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国修复重建外科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7507/1002-1892.202408068","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To summarize the characteristics of posterior coronal banana-shaped fragments and its research progress in treatment of intertrochanteric femoral fracture with cephalomedullary nail, provide valuable reference for clinical practice.

Methods: Relevant domestic and foreign literature was extensively reviewed to summarize the history, anatomical structure of posterior coronal banana-shaped fragments, and the need for reduction and fixation, the influence on the stability of cephalomedullary nail, and the remedies.

Results: The posterior coronal banana-shaped fragments refers to the second level fracture line of the intertrochanteric femoral fracture, involving four anatomical structures, namely, the posterior part of the greater trochanter, the intertrochanteric crest, the lesser trochanter, and the posteromedial cortex. With the wide application of three-dimensional-CT in clinical practice, the posterior coronal banana-shaped fragments were more comprehensively understood. According to whether the anterior extension of the fracture line affects the integrity of the lateral entry of the head and neck implant, the posterior coronal banana-shaped fragments can be divided into small and large ones, of which the large single banana-shaped fragment account for about 20% of the AO/Orthopaedic Trauma Association (AO/OTA) type A2 fractures. If the large fragment involving the posteromedial wall (lesser trochanter) will increase the difficulty of the medial cortical contact reduction; or involving the posterolateral wall and resulting in rupture of the entry portal (type A2.4), which will cause sagittal swing of the nail in the femoral marrow cavity, thereby affecting the stability of the nail. There is no effective technique for reduction and fixation of the banana-shaped fragment nowadays. However, the adverse effects of posterior coronal banana-shaped fragment can be compensated by improving the quality of fracture reduction and choosing high filling cephalomedullary nail.

Conclusion: The posterior coronal banana-shaped fragments can easily lead to the rupture of the entry portal of head-neck implants, cause the sagittal swing of the cephalomedulis nail, and then lead to the loss of fracture reduction and affect the treatment effect. Whether the entry portal rupture or not and its risk factors still need further clinical and basic research.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[后冠状香蕉状碎片的特点及颅髓钉治疗股骨粗隆间骨折的研究进展]。
目的:总结头髓钉治疗股骨粗隆间骨折后冠状香蕉状碎片的特点及研究进展,为临床提供有价值的参考。方法:广泛查阅国内外相关文献,总结冠状后香蕉状碎片的发病历史、解剖结构、复位固定的必要性、对头髓钉稳定性的影响及治疗措施。结果:后冠状香蕉状碎片是指股骨粗隆间骨折的第二级骨折线,累及股骨大转子后部、股骨粗隆间嵴、股骨小转子和股骨后内侧皮质四个解剖结构。随着三维ct在临床中的广泛应用,对冠状后香蕉状碎片的认识更加全面。根据骨折线前伸是否影响头颈假体外侧入口完整性,后冠状香蕉状碎片可分为大小两种,其中大单香蕉状碎片约占AO/Orthopaedic Trauma Association (AO/OTA) A2型骨折的20%。如果大碎片累及后内侧壁(小粗隆)会增加内侧皮质接触复位的难度;或累及后外壁,导致进入门静脉破裂(A2.4型),引起股骨髓腔内钉矢状摆动,从而影响钉的稳定性。目前还没有有效的香蕉形骨折复位固定技术。但提高骨折复位质量和选择高填充头髓钉可弥补后冠状香蕉状碎片的不良影响。结论:后冠状香蕉状碎片易导致头颈植入物入口破裂,引起头髓内钉矢状摆动,进而导致骨折复位丧失,影响治疗效果。入口门静脉是否破裂及其危险因素还需要进一步的临床和基础研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中国修复重建外科杂志
中国修复重建外科杂志 Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
11334
期刊介绍:
期刊最新文献
[Application of delayed replantation of degloving skin preserved at 4 in treatment of limb degloving injuries]. [Application of elbow skin fold extension line in extreme elbow flexion in ulnar Kirschner wire insertion of extended supracondylar humeral fractures in children]. [Application of personalized three-dimensional printed customized prostheses in severe Paprosky type acetabular bone defects]. [Applications and prospects of graphene and its derivatives in bone repair]. [Comparison of effectiveness between two surgical methods for humeral lateral condyle fractures in children].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1