Improvement of a pendulum-type apparatus for friction test of a contact lens to simulate the conditions of its actual usage

IF 1.6 Q4 ENGINEERING, BIOMEDICAL Biosurface and Biotribology Pub Date : 2024-11-27 DOI:10.1049/bsb2.12086
Ryusuke Nakaoka, Hiroko Iwashita, Yuichi Hori, Kiyoshi Mabuchi, Toru Matsunaga, Yuji Haishima, Eiichi Yamamoto
{"title":"Improvement of a pendulum-type apparatus for friction test of a contact lens to simulate the conditions of its actual usage","authors":"Ryusuke Nakaoka,&nbsp;Hiroko Iwashita,&nbsp;Yuichi Hori,&nbsp;Kiyoshi Mabuchi,&nbsp;Toru Matsunaga,&nbsp;Yuji Haishima,&nbsp;Eiichi Yamamoto","doi":"10.1049/bsb2.12086","DOIUrl":null,"url":null,"abstract":"<p>Friction between the contact lens (CL) and the corneal or conjunctival surfaces is considered one of key factors in triggering CL-associated adverse effects. However, the relationship between friction properties and these effects remains unclear. Traditional measurement methods often fail to replicate real-life conditions, thereby highlighting the need for more effective apparatus. In this study, the authors developed an optimised pendulum apparatus integrated with an inclinometer to enhance the measurement of CL friction coefficients, thereby improving its precision and relevance to clinical settings. This new design allows for faster and easier calculation of the friction coefficient based on the amplitude decay per libration cycle, surpassing the accuracy of previous video-based methods. The pendulum's hemisphere component was made from ethylene–propylene–diene monomer rubber (EPDM) 30, which has an elastic modulus similar to that of a human eyeball, creating a measurement environment that closely mimics real-world usage. The authors optimised the apparatus by evaluating the effects of hemisphere stiffness and saline volume on the friction coefficient. Measurements of multiple lenses recorded by the authors, particularly Lens A, made of narafilcon A, revealed significant consistency across different hemisphere materials with an optimal saline volume of 150 μL yielding a friction coefficient of 0.026 ± 0.003. No statistically significant differences in the friction coefficients were found across variations in the lens base curve, diameter, centre thickness, or power. This improved apparatus demonstrates the capability of effectively measuring friction coefficients under conditions that simulate clinical usage, providing rapid and reliable results. The findings validate the apparatus and suggest its potential for broader applications in assessing CL properties, thereby facilitating future research on the material characteristics and safety of various CLs, including decorative lenses.</p>","PeriodicalId":52235,"journal":{"name":"Biosurface and Biotribology","volume":"10 4","pages":"167-175"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/bsb2.12086","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosurface and Biotribology","FirstCategoryId":"1087","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/bsb2.12086","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Friction between the contact lens (CL) and the corneal or conjunctival surfaces is considered one of key factors in triggering CL-associated adverse effects. However, the relationship between friction properties and these effects remains unclear. Traditional measurement methods often fail to replicate real-life conditions, thereby highlighting the need for more effective apparatus. In this study, the authors developed an optimised pendulum apparatus integrated with an inclinometer to enhance the measurement of CL friction coefficients, thereby improving its precision and relevance to clinical settings. This new design allows for faster and easier calculation of the friction coefficient based on the amplitude decay per libration cycle, surpassing the accuracy of previous video-based methods. The pendulum's hemisphere component was made from ethylene–propylene–diene monomer rubber (EPDM) 30, which has an elastic modulus similar to that of a human eyeball, creating a measurement environment that closely mimics real-world usage. The authors optimised the apparatus by evaluating the effects of hemisphere stiffness and saline volume on the friction coefficient. Measurements of multiple lenses recorded by the authors, particularly Lens A, made of narafilcon A, revealed significant consistency across different hemisphere materials with an optimal saline volume of 150 μL yielding a friction coefficient of 0.026 ± 0.003. No statistically significant differences in the friction coefficients were found across variations in the lens base curve, diameter, centre thickness, or power. This improved apparatus demonstrates the capability of effectively measuring friction coefficients under conditions that simulate clinical usage, providing rapid and reliable results. The findings validate the apparatus and suggest its potential for broader applications in assessing CL properties, thereby facilitating future research on the material characteristics and safety of various CLs, including decorative lenses.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
改进用于隐形眼镜摩擦测试的摆锤式仪器,模拟实际使用条件
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Biosurface and Biotribology
Biosurface and Biotribology Engineering-Mechanical Engineering
CiteScore
1.70
自引率
0.00%
发文量
27
审稿时长
11 weeks
期刊最新文献
Preparation and biological activity study of Ti13Nb13Zr surface nanotubes Improvement of a pendulum-type apparatus for friction test of a contact lens to simulate the conditions of its actual usage Machine learning-based investigations of the effect of surface texture geometry on the wear behaviour of UHMWPE bearings in hip joint implants Protein hydrogels for biomedical applications Flow field characteristics and drag reduction performance of high–low velocity stripes on the biomimetic imbricated fish scale surfaces
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1