Robotic dual-docking surgery for para-aortic lymphadenectomy in endometrial cancer: a prospective feasibility study.

IF 2.4 3区 医学 Q3 ONCOLOGY International Journal of Clinical Oncology Pub Date : 2024-12-21 DOI:10.1007/s10147-024-02635-8
Shintaro Yanazume, Hiroaki Kobayashi, Takashi Ushiwaka, Shinichi Togami, Masaki Kamio
{"title":"Robotic dual-docking surgery for para-aortic lymphadenectomy in endometrial cancer: a prospective feasibility study.","authors":"Shintaro Yanazume, Hiroaki Kobayashi, Takashi Ushiwaka, Shinichi Togami, Masaki Kamio","doi":"10.1007/s10147-024-02635-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The standard for robotic para-aortic lymphadenectomy has not been fully established. Para-aortic lymphadenectomy performed by sharing the same ports with pelvic procedures, a procedure known as dual-docking surgery, can be performed using the latest robotic system. We prospectively examined the ability of standardized dual-docking robotic surgery in endometrial cancer patients.</p><p><strong>Methods: </strong>This study prospectively verified the feasibility and safety of dual-docking robotic surgeries performed between March 2017 and December 2021. The laterally placed ports were aligned with the umbilicus. Primary outcome was the surgical completion rate; secondary outcomes were blood loss, operative time, unexpected port placement, conversion, complications, length of hospital stay, and survival.</p><p><strong>Results: </strong>Most patients (14/15, 93%) underwent surgery using our methods without additional port placements, and one patient was converted to laparotomy. Median blood loss was 162 mL (range: 20-685 mL). Median operative time was 183 and 206 min in the upper and lower abdomen. Median number of resected para-aortic lymph nodes was 19 (range: 6-29), and pelvic lymph nodes was 28 (range: 15-42). Although there was no difficulty in moving the forceps intraoperatively, major complications including vessel injury, and pelvic abscesses were observed. The lateral ports could be placed 6-10 cm apart in patients with any range of body type.</p><p><strong>Conclusion: </strong>Dual-docking surgery for endometrial cancer has the potential to be a standard procedure for robotic endometrial cancer surgery, although a greater number of cases are needed to acquire proficiency.</p>","PeriodicalId":13869,"journal":{"name":"International Journal of Clinical Oncology","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2024-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Clinical Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10147-024-02635-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The standard for robotic para-aortic lymphadenectomy has not been fully established. Para-aortic lymphadenectomy performed by sharing the same ports with pelvic procedures, a procedure known as dual-docking surgery, can be performed using the latest robotic system. We prospectively examined the ability of standardized dual-docking robotic surgery in endometrial cancer patients.

Methods: This study prospectively verified the feasibility and safety of dual-docking robotic surgeries performed between March 2017 and December 2021. The laterally placed ports were aligned with the umbilicus. Primary outcome was the surgical completion rate; secondary outcomes were blood loss, operative time, unexpected port placement, conversion, complications, length of hospital stay, and survival.

Results: Most patients (14/15, 93%) underwent surgery using our methods without additional port placements, and one patient was converted to laparotomy. Median blood loss was 162 mL (range: 20-685 mL). Median operative time was 183 and 206 min in the upper and lower abdomen. Median number of resected para-aortic lymph nodes was 19 (range: 6-29), and pelvic lymph nodes was 28 (range: 15-42). Although there was no difficulty in moving the forceps intraoperatively, major complications including vessel injury, and pelvic abscesses were observed. The lateral ports could be placed 6-10 cm apart in patients with any range of body type.

Conclusion: Dual-docking surgery for endometrial cancer has the potential to be a standard procedure for robotic endometrial cancer surgery, although a greater number of cases are needed to acquire proficiency.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.80
自引率
3.00%
发文量
175
审稿时长
2 months
期刊介绍: The International Journal of Clinical Oncology (IJCO) welcomes original research papers on all aspects of clinical oncology that report the results of novel and timely investigations. Reports on clinical trials are encouraged. Experimental studies will also be accepted if they have obvious relevance to clinical oncology. Membership in the Japan Society of Clinical Oncology is not a prerequisite for submission to the journal. Papers are received on the understanding that: their contents have not been published in whole or in part elsewhere; that they are subject to peer review by at least two referees and the Editors, and to editorial revision of the language and contents; and that the Editors are responsible for their acceptance, rejection, and order of publication.
期刊最新文献
Robotic dual-docking surgery for para-aortic lymphadenectomy in endometrial cancer: a prospective feasibility study. Prognostic significance of lymph node metastasis of soft tissue sarcoma of the extremities. National cancer institute experience. Efficacy of androgen receptor signaling inhibitors in combination with androgen deprivation therapy for castration-sensitive metastatic prostate cancer: a retrospective analysis in a Japanese cohort. Postoperative adjuvant therapy with molecularly targeted agents for non-small cell lung cancer. Age-related genomic alterations and chemotherapy sensitivity in osteosarcoma: insights from cancer genome profiling analyses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1