Wear resistance of 3D printed, milled, and prefabricated methacrylate-based resin materials: An in vitro study.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2024-12-20 DOI:10.1016/j.prosdent.2024.12.006
Passupang Veerapeindee, Pimduen Rungsiyakull, Wissanee Jia-Mahasap
{"title":"Wear resistance of 3D printed, milled, and prefabricated methacrylate-based resin materials: An in vitro study.","authors":"Passupang Veerapeindee, Pimduen Rungsiyakull, Wissanee Jia-Mahasap","doi":"10.1016/j.prosdent.2024.12.006","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Three-dimensional (3D) printing and milling technologies have been increasingly used in prosthodontic practice for fabricating digital prostheses. Nevertheless, evidence relating to the wear resistance of denture teeth fabricated using these methods is lacking.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to compare the wear resistance exhibited by denture teeth fabricated using 3D printing and milling technologies with prefabricated denture teeth.</p><p><strong>Material and methods: </strong>Fifty specimens of resin denture teeth from 3 types of manufacturing processes were prepared and divided into 5 groups: 1 group of 3D printed denture teeth (NextDent C&B MFH), 2 groups of milled denture teeth (Ivotion Dent and VIPI Block), and 2 groups of prefabricated denture teeth (Major Dent and Cosmo HXL). Each group of specimens was occluded with a zirconia antagonist under a 49-N load with thermocycling conditions for 120 000 cycles. The antagonist was horizontally displaced back and forth at a 2-mm distance and a frequency of 1.6 Hz. The quantification of the volume loss and the maximal wear depth of the worn specimens were recorded, while the wear characteristics were assessed with a scanning electron microscope (SEM). Data were analyzed using the Kruskal-Wallis test followed by pairwise comparison tests (α=.05).</p><p><strong>Results: </strong>Significantly different wear depths and volume losses were found among groups (P<.05). The highest wear depth and volume loss were observed in the VIPI Block (0.513 ±0.147 mm and 3.094 ±0.790 mm³), followed by Cosmo HXL group (0.312 ±0.020 mm and 1.446 ±0.134 mm³), Major Dent (0.261 ±0.034 mm and 1.219 ±0.196 mm³), Ivotion Dent (0.253 ±0.021 mm and 1.082 ±0.089 mm³), and NextDent C&B MFH (0.208 ±0.059 mm and 0.843 ±0.372 mm³). Based on the analysis of the SEM images, distinct groups of specimens exhibited varying degrees of crack formation. Furthermore, their worn surfaces showed diverse characteristics in terms of wear patterns and roughness attributes.</p><p><strong>Conclusions: </strong>The manufacturing methods for fabricating 3D printed, milled, and prefabricated denture teeth exhibit comparable wear resistance, with 3D printed denture teeth demonstrating the highest level of wear resistance.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.12.006","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: Three-dimensional (3D) printing and milling technologies have been increasingly used in prosthodontic practice for fabricating digital prostheses. Nevertheless, evidence relating to the wear resistance of denture teeth fabricated using these methods is lacking.

Purpose: The purpose of this in vitro study was to compare the wear resistance exhibited by denture teeth fabricated using 3D printing and milling technologies with prefabricated denture teeth.

Material and methods: Fifty specimens of resin denture teeth from 3 types of manufacturing processes were prepared and divided into 5 groups: 1 group of 3D printed denture teeth (NextDent C&B MFH), 2 groups of milled denture teeth (Ivotion Dent and VIPI Block), and 2 groups of prefabricated denture teeth (Major Dent and Cosmo HXL). Each group of specimens was occluded with a zirconia antagonist under a 49-N load with thermocycling conditions for 120 000 cycles. The antagonist was horizontally displaced back and forth at a 2-mm distance and a frequency of 1.6 Hz. The quantification of the volume loss and the maximal wear depth of the worn specimens were recorded, while the wear characteristics were assessed with a scanning electron microscope (SEM). Data were analyzed using the Kruskal-Wallis test followed by pairwise comparison tests (α=.05).

Results: Significantly different wear depths and volume losses were found among groups (P<.05). The highest wear depth and volume loss were observed in the VIPI Block (0.513 ±0.147 mm and 3.094 ±0.790 mm³), followed by Cosmo HXL group (0.312 ±0.020 mm and 1.446 ±0.134 mm³), Major Dent (0.261 ±0.034 mm and 1.219 ±0.196 mm³), Ivotion Dent (0.253 ±0.021 mm and 1.082 ±0.089 mm³), and NextDent C&B MFH (0.208 ±0.059 mm and 0.843 ±0.372 mm³). Based on the analysis of the SEM images, distinct groups of specimens exhibited varying degrees of crack formation. Furthermore, their worn surfaces showed diverse characteristics in terms of wear patterns and roughness attributes.

Conclusions: The manufacturing methods for fabricating 3D printed, milled, and prefabricated denture teeth exhibit comparable wear resistance, with 3D printed denture teeth demonstrating the highest level of wear resistance.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Digital trifunctional intraoral appliance for centric relation recording: A dental technique. Effect of different surface treatments on PEEK-enamel bonds: Bonding durability and mechanism. Wear resistance of 3D printed, milled, and prefabricated methacrylate-based resin materials: An in vitro study. Trueness of maxillary complete dentures duplicated by using conventional and 3D printing techniques: A comparative in vitro study. Advancing 3D dental scanning: The use of photogrammetry with light detection and ranging for edentulous arches.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1