Comparison of the diagnostic performances of ct attenuation corrected and non-attenuation corrected spect myocardial perfusion scintigraphy in coronary artery disease.

G Kara Gedik, A Volkan Çelik, M U Yalçın, M Koplay, F Yılmaz, H Önner
{"title":"Comparison of the diagnostic performances of ct attenuation corrected and non-attenuation corrected spect myocardial perfusion scintigraphy in coronary artery disease.","authors":"G Kara Gedik, A Volkan Çelik, M U Yalçın, M Koplay, F Yılmaz, H Önner","doi":"10.1016/j.remnie.2024.500085","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction and objectives: </strong>Tissue attenuation reduces the specificity of the myocardial perfusion imaging single photon emission tomography (SPECT), which leads reduced diagnostic accuracy. The aim of this study is to compare performances of non-attenuation corrected (NAC), computed tomography based-attenuation corrected (AC) and prone images for qualitative and semi-quantitative analysis of myocardial perfusion SPECT in diagnosis of coronary artery disease (CAD).</p><p><strong>Materials and methods: </strong>Eightysix patients in whom NAC, AC and prone images were obtained with SPECT at Selcuk University Faculty of Medicine, and whose coronary angiography/CT coronary angiography was completed within 3 months, were retrospectively studied. Myocardial perfusion scintigraphy was performed using SPECT/CT dual-headed gamma camera. Images were evaluated qualitatively and semi-quantitatively using 20-segment model. Analyzes of global myocardium and LAD, RCA, Cx vascular areas as regional analysis were performed. In qualitative evaluation, if SPECT study was abnormal, relevant coronary artery area was recorded. Quantitative Perfusion SPECT (QPS) program was used in semi-quantitative analysis; SSS ≥ 4 was accepted for presence of CAD in per-patient analysis. In regional analysis SSS ≥ 2 was taken into account. Coronary angiography/CT coronary angiography was used as gold standard. Threshold value was determined as ≥50% and above luminal diameter narrowing. While AC and NAC methods were compared for per-patient analysis and each vascular area; 3 imaging methods including prone acqusition, were compared for the RCA area. Diagnostic performances of the methods were evaluated by comparing the areas under the curve with ROC analysis.</p><p><strong>Results: </strong>In visual evaluation, sensitivity of AC was significantly lower than NAC in analyzes of per-patient, RCA and Cx areas (global 76.92% vs 86.15%, RCA 60.87% vs 82.61%, Cx 58.97% vs 69.23%, respectively; p < 0.05 ). Sensitivity of prone imaging was significantly higher than AC in analysis of the RCA area (76.09% vs 60.87%, respectively; p < 0.05) Specificity values ​​were higher in analyzes of global, RCA and Cx areas in AC than in NAC method; this difference was significant in RCA and Cx areas (RCA 70% vs 42.50%, Cx 85.11% vs 70.21%, respectively; p < 0.05). In semi-quantitative evaluation, AC and NAC had similar sensitivity and specificity in global and regional analyzes; in RCA area, no significant difference was detected between the 3 methods. In ROC analysis, no significant difference was detected between methods in per-patient and regional analyzes both in visual and semi-quantitative evaluation.</p><p><strong>Conclusions: </strong>CT-based attenuation correction increases specificity, but reduces sensitivity in the diagnosis of CAD in regional areas of RCA and Cx. Prone imaging remains important in evaluation of RCA area.</p>","PeriodicalId":94197,"journal":{"name":"Revista espanola de medicina nuclear e imagen molecular","volume":" ","pages":"500085"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista espanola de medicina nuclear e imagen molecular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.remnie.2024.500085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objectives: Tissue attenuation reduces the specificity of the myocardial perfusion imaging single photon emission tomography (SPECT), which leads reduced diagnostic accuracy. The aim of this study is to compare performances of non-attenuation corrected (NAC), computed tomography based-attenuation corrected (AC) and prone images for qualitative and semi-quantitative analysis of myocardial perfusion SPECT in diagnosis of coronary artery disease (CAD).

Materials and methods: Eightysix patients in whom NAC, AC and prone images were obtained with SPECT at Selcuk University Faculty of Medicine, and whose coronary angiography/CT coronary angiography was completed within 3 months, were retrospectively studied. Myocardial perfusion scintigraphy was performed using SPECT/CT dual-headed gamma camera. Images were evaluated qualitatively and semi-quantitatively using 20-segment model. Analyzes of global myocardium and LAD, RCA, Cx vascular areas as regional analysis were performed. In qualitative evaluation, if SPECT study was abnormal, relevant coronary artery area was recorded. Quantitative Perfusion SPECT (QPS) program was used in semi-quantitative analysis; SSS ≥ 4 was accepted for presence of CAD in per-patient analysis. In regional analysis SSS ≥ 2 was taken into account. Coronary angiography/CT coronary angiography was used as gold standard. Threshold value was determined as ≥50% and above luminal diameter narrowing. While AC and NAC methods were compared for per-patient analysis and each vascular area; 3 imaging methods including prone acqusition, were compared for the RCA area. Diagnostic performances of the methods were evaluated by comparing the areas under the curve with ROC analysis.

Results: In visual evaluation, sensitivity of AC was significantly lower than NAC in analyzes of per-patient, RCA and Cx areas (global 76.92% vs 86.15%, RCA 60.87% vs 82.61%, Cx 58.97% vs 69.23%, respectively; p < 0.05 ). Sensitivity of prone imaging was significantly higher than AC in analysis of the RCA area (76.09% vs 60.87%, respectively; p < 0.05) Specificity values ​​were higher in analyzes of global, RCA and Cx areas in AC than in NAC method; this difference was significant in RCA and Cx areas (RCA 70% vs 42.50%, Cx 85.11% vs 70.21%, respectively; p < 0.05). In semi-quantitative evaluation, AC and NAC had similar sensitivity and specificity in global and regional analyzes; in RCA area, no significant difference was detected between the 3 methods. In ROC analysis, no significant difference was detected between methods in per-patient and regional analyzes both in visual and semi-quantitative evaluation.

Conclusions: CT-based attenuation correction increases specificity, but reduces sensitivity in the diagnosis of CAD in regional areas of RCA and Cx. Prone imaging remains important in evaluation of RCA area.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
18F-FDG and 11C-PIB PET/TC findings in status epilepticus in the setting of a patient with mild cognitive impairment. Analysis of dosimetry and clinical variables in treatments of neuroendocrine tumours with [177Lu]Lu-DOTA-TATE. Comparison of the diagnostic performances of ct attenuation corrected and non-attenuation corrected spect myocardial perfusion scintigraphy in coronary artery disease. Correlation between [18F]-FDG PET/CT findings and pathological subtypes of lung adenocarcinoma presenting as ground-glass opacity. False Lymph Node Recurrence Image in PET/CT with [68Ga]Ga-PSMA-11. Importance of the Acquisition Protocol.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1