Automated Insulin Delivery in Older Adults with Type 1 Diabetes.

NEJM evidence Pub Date : 2025-01-01 Epub Date: 2024-12-23 DOI:10.1056/EVIDoa2400200
Yogish C Kudva, Robert J Henderson, Lauren G Kanapka, Ruth S Weinstock, Michael R Rickels, Richard E Pratley, Naomi Chaytor, Kamille Janess, Donna Desjardins, Vishwanath Pattan, Amy J Peleckis, Anna Casu, Shafaq Raza Rizvi, Suzan Bzdick, Keri J Whitaker, Jorge L Jo Kamimoto, Kellee Miller, Craig Kollman, Roy W Beck
{"title":"Automated Insulin Delivery in Older Adults with Type 1 Diabetes.","authors":"Yogish C Kudva, Robert J Henderson, Lauren G Kanapka, Ruth S Weinstock, Michael R Rickels, Richard E Pratley, Naomi Chaytor, Kamille Janess, Donna Desjardins, Vishwanath Pattan, Amy J Peleckis, Anna Casu, Shafaq Raza Rizvi, Suzan Bzdick, Keri J Whitaker, Jorge L Jo Kamimoto, Kellee Miller, Craig Kollman, Roy W Beck","doi":"10.1056/EVIDoa2400200","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Older adults with type 1 diabetes are at risk for serious hypoglycemia. Automated insulin delivery can reduce risk but has not been sufficiently evaluated in this population.</p><p><strong>Methods: </strong>We conducted a multicenter, randomized crossover trial in adults older than or equal to 65 years of age with type 1 diabetes. Participants completed three 12-week periods of using hybrid closed loop, predictive low-glucose suspend, and sensor-augmented pump insulin delivery in a randomized order. The primary outcome was the percentage of time with continuous glucose monitoring glucose values less than 70 mg/dl.</p><p><strong>Results: </strong>Eighty-two participants between 65 and 86 years of age were randomly assigned: 45% were female; the baseline mean (±SD) glycated hemoglobin level was 7.2±0.9%; and the baseline percentage of time with glucose values less than 70 mg/dl was 2.49±1.78%. In the sensor-augmented pump, hybrid closed-loop, and predictive low-glucose suspend periods, percentages of time with glucose less than 70 mg/dl were 2.57±1.54%, 1.58±0.95%, and 1.67±0.96%, respectively. Compared with the sensor-augmented pump results, the mean difference with the hybrid closed-loop system was -1.05 percentage points (95% confidence interval [CI], -1.48 to -0.73 percentage points; P<0.001) and with the predictive low-glucose suspend system it was -0.93 percentage points (95% CI, -1.27 to -0.66 percentage points; P<0.001). Comparing a hybrid closed-loop system with a sensor-augmented pump, time in the range 70 to 180 mg/dl changed by 8.9 percentage points (95% CI, 7.4 to 10.4 percentage points) and the glycated hemoglobin level changed by 0.2 percentage points (95% CI, -0.3 to -0.1 percentage points). Serious adverse events were uncommon. Severe hypoglycemia occurred in 4% or less of participants; there were two hospitalizations for diabetic ketoacidosis.</p><p><strong>Conclusions: </strong>In older adults with type 1 diabetes, automated insulin delivery decreased hypoglycemia compared with sensor-augmented pump delivery. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number: NCT04016662.).</p>","PeriodicalId":74256,"journal":{"name":"NEJM evidence","volume":"4 1","pages":"EVIDoa2400200"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NEJM evidence","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1056/EVIDoa2400200","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Older adults with type 1 diabetes are at risk for serious hypoglycemia. Automated insulin delivery can reduce risk but has not been sufficiently evaluated in this population.

Methods: We conducted a multicenter, randomized crossover trial in adults older than or equal to 65 years of age with type 1 diabetes. Participants completed three 12-week periods of using hybrid closed loop, predictive low-glucose suspend, and sensor-augmented pump insulin delivery in a randomized order. The primary outcome was the percentage of time with continuous glucose monitoring glucose values less than 70 mg/dl.

Results: Eighty-two participants between 65 and 86 years of age were randomly assigned: 45% were female; the baseline mean (±SD) glycated hemoglobin level was 7.2±0.9%; and the baseline percentage of time with glucose values less than 70 mg/dl was 2.49±1.78%. In the sensor-augmented pump, hybrid closed-loop, and predictive low-glucose suspend periods, percentages of time with glucose less than 70 mg/dl were 2.57±1.54%, 1.58±0.95%, and 1.67±0.96%, respectively. Compared with the sensor-augmented pump results, the mean difference with the hybrid closed-loop system was -1.05 percentage points (95% confidence interval [CI], -1.48 to -0.73 percentage points; P<0.001) and with the predictive low-glucose suspend system it was -0.93 percentage points (95% CI, -1.27 to -0.66 percentage points; P<0.001). Comparing a hybrid closed-loop system with a sensor-augmented pump, time in the range 70 to 180 mg/dl changed by 8.9 percentage points (95% CI, 7.4 to 10.4 percentage points) and the glycated hemoglobin level changed by 0.2 percentage points (95% CI, -0.3 to -0.1 percentage points). Serious adverse events were uncommon. Severe hypoglycemia occurred in 4% or less of participants; there were two hospitalizations for diabetic ketoacidosis.

Conclusions: In older adults with type 1 diabetes, automated insulin delivery decreased hypoglycemia compared with sensor-augmented pump delivery. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number: NCT04016662.).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Blood Pressure Targets for Adults with Vasodilatory Shock - An Individual Patient Data Meta-Analysis. BNC210, an α7 Nicotinic Receptor Modulator, in Post-Traumatic Stress Disorder. A Meta-Analysis of Levofloxacin for Contacts of Multidrug-Resistant Tuberculosis. Treating Patients, Not P Values. A 50-Year-Old Man with Left-Sided Weakness and Difficulty Speaking Clearly.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1