Correlation between fluorescein flowmetry, 133Xenon clearance and electromagnetic flow measurement: a study in the intestine of the pig.

L Perbeck, D H Lewis, L Thulin, G Tydén
{"title":"Correlation between fluorescein flowmetry, 133Xenon clearance and electromagnetic flow measurement: a study in the intestine of the pig.","authors":"L Perbeck,&nbsp;D H Lewis,&nbsp;L Thulin,&nbsp;G Tydén","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of the present study was to compare fluorescein flowmetry as a technique for measuring changes in intestine blood flow with electromagnetic blood flowmetry and the 133Xenon clearance technique. In eight anaesthetized pigs the blood flow in the superior mesenteric artery was reduced to 20-75% of basal flow as defined by electromagnetic flowmetry. The change in blood flow as calculated by fluorescein flowmetry correlated well with that obtained by electromagnetic blood flowmetry (correlation coefficient 0.86) and 133Xenon clearance technique (correlation coefficient 0.94). These findings indicate that fluorescein flowmetry can be considered a quantitative method for measurements of a relative blood flow.</p>","PeriodicalId":77071,"journal":{"name":"Clinical physiology (Oxford, England)","volume":"5 3","pages":"293-9"},"PeriodicalIF":0.0000,"publicationDate":"1985-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical physiology (Oxford, England)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of the present study was to compare fluorescein flowmetry as a technique for measuring changes in intestine blood flow with electromagnetic blood flowmetry and the 133Xenon clearance technique. In eight anaesthetized pigs the blood flow in the superior mesenteric artery was reduced to 20-75% of basal flow as defined by electromagnetic flowmetry. The change in blood flow as calculated by fluorescein flowmetry correlated well with that obtained by electromagnetic blood flowmetry (correlation coefficient 0.86) and 133Xenon clearance technique (correlation coefficient 0.94). These findings indicate that fluorescein flowmetry can be considered a quantitative method for measurements of a relative blood flow.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
荧光素流量法、133氙清除率与电磁流量法在猪肠道中的相关性研究。
本研究的目的是比较荧光素血流法作为一种测量肠血流变化的技术与电磁血流法和133氙清除技术。在8只麻醉猪中,肠系膜上动脉的血流量减少到电磁流量测定的基础流量的20-75%。荧光素血流法计算的血流量变化与电磁血流法(相关系数0.86)和133氙清除技术(相关系数0.94)计算的血流量变化具有良好的相关性。这些发现表明,荧光素血流法可以被认为是一种定量方法的测量相对血流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Subdural hematoma presenting as trigeminal neuralgia: A case report. Identification of a mannitol transporter, AgMaT1, in celery phloem. Pacing-induced palmar sweating evaluated by unique hygrometer: possible implications of sympathetic activation during tachycardia. Into the 20th volume and the 21st century Non-linear cardiac dynamics and morning dip: an unsound circadian rhythm.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1