Ibrahim Antoun, Xin Li, Zakariyya Vali, Ahmed Kotb, Ahmed Abdelrazik, Ivelin Koev, Riyaz Somani, G André Ng
{"title":"The Value of P-Wave Parameters Changes in Predicting Catheter Ablation Outcomes for Paroxysmal Atrial Fibrillation.","authors":"Ibrahim Antoun, Xin Li, Zakariyya Vali, Ahmed Kotb, Ahmed Abdelrazik, Ivelin Koev, Riyaz Somani, G André Ng","doi":"10.1111/anec.70047","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulmonary vein isolation (PVI) is the most promising management method for paroxysmal atrial fibrillation (PAF). The P wave in the electrocardiogram (ECG) represents atrial depolarization. This study aims to correlate P-wave parameters after PVI with outcomes.</p><p><strong>Methods: </strong>This single-center retrospective study included consecutive patients with first-time PVI for PAF between 2018 and 2019 and targeted pulmonary veins (PVs). Procedure success was defined by freedom of ECG-documented AF at 12 months. Digital 12 leads ECGs with 1-50 hertz bandpass filter were monitored before the procedure. P-wave amplitude (PWA) and P-wave terminal force in V1 (PTFV1) Corrected P-wave duration (PWDc), and P-wave dispersion (PWDisp), were measured before and after ablation.</p><p><strong>Results: </strong>The final analysis included 180 patients, of which 130 (72%) had successful ablations and 53 (30%) had radiofrequency ablation (RF). Males comprised 71% of the patients; the mean age was 60. Demographics were similar between both arms p < 0.001. Patients with failed PVI had increased PWDc after PVI (139-146 ms, p < 0.001) compared to patients with successful PVI. PWA increased significantly after failed PVI (1.6-2 mV, p < 0.001) and successful PVI (1.6-1.8 mV, p = 0.008). PWD (hazard ratio [HR]: 2.5, 95% confidence interval [CI]: 1.4-4.2, p < 0.001) and PWA (HR: 1.7, 95% CI: 1.2-2.9, p = 0.03) were independently associated with PVI failure at 12 months. PWdisp and PTFV1 were not correlated with outcomes.</p><p><strong>Conclusion: </strong>Increased PWDc and PWA after PVI were independently associated with failed ablation for PAF, supporting the role of P-wave parameters in predicting outcomes.</p>","PeriodicalId":8074,"journal":{"name":"Annals of Noninvasive Electrocardiology","volume":"30 1","pages":"e70047"},"PeriodicalIF":1.1000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11686087/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Noninvasive Electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/anec.70047","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Pulmonary vein isolation (PVI) is the most promising management method for paroxysmal atrial fibrillation (PAF). The P wave in the electrocardiogram (ECG) represents atrial depolarization. This study aims to correlate P-wave parameters after PVI with outcomes.
Methods: This single-center retrospective study included consecutive patients with first-time PVI for PAF between 2018 and 2019 and targeted pulmonary veins (PVs). Procedure success was defined by freedom of ECG-documented AF at 12 months. Digital 12 leads ECGs with 1-50 hertz bandpass filter were monitored before the procedure. P-wave amplitude (PWA) and P-wave terminal force in V1 (PTFV1) Corrected P-wave duration (PWDc), and P-wave dispersion (PWDisp), were measured before and after ablation.
Results: The final analysis included 180 patients, of which 130 (72%) had successful ablations and 53 (30%) had radiofrequency ablation (RF). Males comprised 71% of the patients; the mean age was 60. Demographics were similar between both arms p < 0.001. Patients with failed PVI had increased PWDc after PVI (139-146 ms, p < 0.001) compared to patients with successful PVI. PWA increased significantly after failed PVI (1.6-2 mV, p < 0.001) and successful PVI (1.6-1.8 mV, p = 0.008). PWD (hazard ratio [HR]: 2.5, 95% confidence interval [CI]: 1.4-4.2, p < 0.001) and PWA (HR: 1.7, 95% CI: 1.2-2.9, p = 0.03) were independently associated with PVI failure at 12 months. PWdisp and PTFV1 were not correlated with outcomes.
Conclusion: Increased PWDc and PWA after PVI were independently associated with failed ablation for PAF, supporting the role of P-wave parameters in predicting outcomes.
期刊介绍:
The ANNALS OF NONINVASIVE ELECTROCARDIOLOGY (A.N.E) is an online only journal that incorporates ongoing advances in the clinical application and technology of traditional and new ECG-based techniques in the diagnosis and treatment of cardiac patients.
ANE is the first journal in an evolving subspecialty that incorporates ongoing advances in the clinical application and technology of traditional and new ECG-based techniques in the diagnosis and treatment of cardiac patients. The publication includes topics related to 12-lead, exercise and high-resolution electrocardiography, arrhythmias, ischemia, repolarization phenomena, heart rate variability, circadian rhythms, bioengineering technology, signal-averaged ECGs, T-wave alternans and automatic external defibrillation.
ANE publishes peer-reviewed articles of interest to clinicians and researchers in the field of noninvasive electrocardiology. Original research, clinical studies, state-of-the-art reviews, case reports, technical notes, and letters to the editors will be published to meet future demands in this field.