Virginia Fregona , Giulia Luraghi , Behrooz Fereidoonnezhad , Frank J.H. Gijsen , Charles B.L.M. Majoie , Jose Felix Rodríguez Matas , Francesco Migliavacca
{"title":"Impact of thrombus composition on virtual thrombectomy procedures using human clot analogues mechanical data","authors":"Virginia Fregona , Giulia Luraghi , Behrooz Fereidoonnezhad , Frank J.H. Gijsen , Charles B.L.M. Majoie , Jose Felix Rodríguez Matas , Francesco Migliavacca","doi":"10.1016/j.jmbbm.2025.106886","DOIUrl":null,"url":null,"abstract":"<div><div>Endovascular thrombectomy (EVT) aims at restoring blood flow in case of acute ischemic stroke by removing the thrombus occluding a large cerebral artery. During the procedure with stent-retriever, the thrombus is captured within the device, which is then retrieved, subjecting the thrombus to several forces, potentially leading to its fragmentation. <em>In silico</em> studies, along with mechanical characterisation of thrombi, can enhance our understanding of the EVT, helping the development of new devices and interventional strategies. Our group previously validated a numerical approach to study EVT able to account for thrombus fragmentation. In this study, the same methodology was employed to explore the applicability of the chosen failure criterion to EVT simulations and the impact of thrombus composition on the outcome of the <em>in silico</em> procedure. For the first time, human clot analogues experimental data were applied to this methodology. Clot analogues of three different compositions were tested, and a material model incorporating failure was calibrated, followed by a verification analysis. Finally, the calibrated material model was used to perform EVT simulations, combining the three tested thrombus compositions with three different stent retriever models. The experimental tests confirmed a compression-tension asymmetry in the stress-strain curves, showing decreasing stiffness with increasing the red blood cell (RBC) content. Applying the resulting material models to EVT simulations demonstrated: (i) the dependency of the failure criterion on the thrombus mesh size, (ii) a greater tendency for RBC-rich thrombi to fragment, and (iii) increased difficulty in retrieving RBC-poor thrombi compared to RBC-rich thrombi.</div></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"163 ","pages":"Article 106886"},"PeriodicalIF":3.3000,"publicationDate":"2025-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616125000025","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Endovascular thrombectomy (EVT) aims at restoring blood flow in case of acute ischemic stroke by removing the thrombus occluding a large cerebral artery. During the procedure with stent-retriever, the thrombus is captured within the device, which is then retrieved, subjecting the thrombus to several forces, potentially leading to its fragmentation. In silico studies, along with mechanical characterisation of thrombi, can enhance our understanding of the EVT, helping the development of new devices and interventional strategies. Our group previously validated a numerical approach to study EVT able to account for thrombus fragmentation. In this study, the same methodology was employed to explore the applicability of the chosen failure criterion to EVT simulations and the impact of thrombus composition on the outcome of the in silico procedure. For the first time, human clot analogues experimental data were applied to this methodology. Clot analogues of three different compositions were tested, and a material model incorporating failure was calibrated, followed by a verification analysis. Finally, the calibrated material model was used to perform EVT simulations, combining the three tested thrombus compositions with three different stent retriever models. The experimental tests confirmed a compression-tension asymmetry in the stress-strain curves, showing decreasing stiffness with increasing the red blood cell (RBC) content. Applying the resulting material models to EVT simulations demonstrated: (i) the dependency of the failure criterion on the thrombus mesh size, (ii) a greater tendency for RBC-rich thrombi to fragment, and (iii) increased difficulty in retrieving RBC-poor thrombi compared to RBC-rich thrombi.
期刊介绍:
The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials.
The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.