Quantitative Profiling and Mapping of Small Molecules by Laser Desorption-Ionization Mass Spectrometry: Combinations of Carbon-based Nano Matrices and Sample Preparation Protocols

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analyst Pub Date : 2025-01-06 DOI:10.1039/d4an01172d
Ruochen Guo, Rui Lv, Rui Shi, Enhui Wu, Chongqing Ma, Chang Sun, Govinda Mandal, Jian Liu
{"title":"Quantitative Profiling and Mapping of Small Molecules by Laser Desorption-Ionization Mass Spectrometry: Combinations of Carbon-based Nano Matrices and Sample Preparation Protocols","authors":"Ruochen Guo, Rui Lv, Rui Shi, Enhui Wu, Chongqing Ma, Chang Sun, Govinda Mandal, Jian Liu","doi":"10.1039/d4an01172d","DOIUrl":null,"url":null,"abstract":"The choices of matrices and the protocols of sample deposition are critical factors which are convolving with each other in the matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging. Previous reports on MALDI MS matrices only compared their performance in MS signal intensities, and provided the optical microphotos or MALDI MS images of the sample spots, lacking of quantitative evaluation. There is an urgent need to develop multivariate model to evaluate the performance of different combinations between matrices and sample protocols. Herein we report a weighted multivariate model for quantitative profiling combinations of matrices/protocols systematically. Our work includes three types of carbon-based nano matrices, such as two-dimensional graphite oxide (GO) nanosheets, one-dimensional carbon nanotubes (CNTs), and zero-dimensional graphite dots (GDs). Four representative sample protocols for MALDI MSI, including rapid evaporation, seed layer, sandwich, and dry droplet, are examined in our model. We select five important parameters: (1) planar dispersity grading by SEM, (2) planar fluorescence homogeneity, (3) coefficient variations in MS signals, (4) MS signal-to-noise ratio, and (5) planar MS signal heatmap grading, with individually assigned weights according to their significance in MSI performance. Calculation of the radar chart areas based on our model provides quantitative profiles for individual combinations. Among them, the dry droplet protocol using the matrix of GDs offers the largest radar chart area, indicating a favorable combination choice for MSI. This work proposes a multivariate model to systematically compare different combinations of matrices and sample protocols, promising a useful tool for mapping small molecules by LDI MS.","PeriodicalId":63,"journal":{"name":"Analyst","volume":"28 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4an01172d","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The choices of matrices and the protocols of sample deposition are critical factors which are convolving with each other in the matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging. Previous reports on MALDI MS matrices only compared their performance in MS signal intensities, and provided the optical microphotos or MALDI MS images of the sample spots, lacking of quantitative evaluation. There is an urgent need to develop multivariate model to evaluate the performance of different combinations between matrices and sample protocols. Herein we report a weighted multivariate model for quantitative profiling combinations of matrices/protocols systematically. Our work includes three types of carbon-based nano matrices, such as two-dimensional graphite oxide (GO) nanosheets, one-dimensional carbon nanotubes (CNTs), and zero-dimensional graphite dots (GDs). Four representative sample protocols for MALDI MSI, including rapid evaporation, seed layer, sandwich, and dry droplet, are examined in our model. We select five important parameters: (1) planar dispersity grading by SEM, (2) planar fluorescence homogeneity, (3) coefficient variations in MS signals, (4) MS signal-to-noise ratio, and (5) planar MS signal heatmap grading, with individually assigned weights according to their significance in MSI performance. Calculation of the radar chart areas based on our model provides quantitative profiles for individual combinations. Among them, the dry droplet protocol using the matrix of GDs offers the largest radar chart area, indicating a favorable combination choice for MSI. This work proposes a multivariate model to systematically compare different combinations of matrices and sample protocols, promising a useful tool for mapping small molecules by LDI MS.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
激光解吸-电离质谱法对小分子的定量分析和测绘:碳基纳米基质和样品制备方案的组合
在基质辅助激光解吸电离(MALDI)质谱成像过程中,基质的选择和样品沉积方案是相互影响的关键因素。以往关于 MALDI 质谱基质的报告仅比较了它们在质谱信号强度方面的性能,并提供了样品点的光学显微照片或 MALDI 质谱图像,缺乏定量评估。目前迫切需要建立多元模型来评估不同基质和样品方案组合的性能。在此,我们报告了一个加权多元模型,用于系统地定量分析基质/方案的组合。我们的工作包括三种碳基纳米基质,如二维氧化石墨(GO)纳米片、一维碳纳米管(CNTs)和零维石墨点(GDs)。我们的模型研究了四种具有代表性的 MALDI MSI 样品方案,包括快速蒸发、种子层、夹层和干液滴。我们选择了五个重要参数:(1) 扫描电镜平面分散性分级;(2) 平面荧光均匀性;(3) MS 信号的系数变化;(4) MS 信噪比;(5) 平面 MS 信号热图分级,并根据它们在 MSI 性能中的重要性分别赋予权重。根据我们的模型计算雷达图区域,可为各个组合提供定量剖面图。其中,使用 GD 矩阵的干液滴方案提供了最大的雷达图面积,表明这是 MSI 的有利组合选择。这项工作提出了一个多变量模型,用于系统地比较不同的基质和样品方案组合,有望成为利用 LDI MS 绘制小分子图谱的有用工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
期刊最新文献
Visualization Methods for Loop Mediated Isothermal Amplification (LAMP) Assays. Screening analysis of doping agents in horse urine and plasma with dilute and shoot using liquid chromatography high resolution mass spectrometry Effects of supplementation of macular pigment carotenoids on ocular health: a Raman spectroscopic study of human blood serum of glaucoma patients A lanmodulin-based fluorescent assay for the rapid and sensitive detection of rare earth elements A bis-pyrene polyamine receptor for fast optical detection of ketoprofen: synthesis, characterization and application in all-solid-state fluorescent sensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1