Continual Versus Occasional Blood Pressure (COOL-BP) in Remote Hypertension Management.

IF 3.2 3区 医学 Q2 PERIPHERAL VASCULAR DISEASE American Journal of Hypertension Pub Date : 2025-01-10 DOI:10.1093/ajh/hpaf003
Ozan Unlu, Christopher P Cannon, Simin Lee, Daniel Gabovitch, David Zelle, Nicholas Chin, Christian Figueroa, Emma Collins, Ryan Ruggiero, Tiago P Almeida, David Perruchoud, Josep Sola, Benjamin M Scirica, Naomi D L Fisher
{"title":"Continual Versus Occasional Blood Pressure (COOL-BP) in Remote Hypertension Management.","authors":"Ozan Unlu, Christopher P Cannon, Simin Lee, Daniel Gabovitch, David Zelle, Nicholas Chin, Christian Figueroa, Emma Collins, Ryan Ruggiero, Tiago P Almeida, David Perruchoud, Josep Sola, Benjamin M Scirica, Naomi D L Fisher","doi":"10.1093/ajh/hpaf003","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Remote hypertension management programs have emerged as potential solutions to improve poor rates of blood pressure (BP) control. The Continual Versus Occasional Blood Pressure (COOL-BP) Study investigated the feasibility and efficacy of using a cuffless wrist BP monitor in a remote hypertension (HTN) program.</p><p><strong>Methods: </strong>COOL-BP was a prospective single-arm study within a larger HTN management program at Mass General Brigham (MGB). Participants had uncontrolled HTN, were already engaged in the MGB Remote Hypertension Program, and used a smartphone. The study involved patients wearing the Aktiia cuffless wrist BP monitor and performing traditional home BP monitoring (HBPM). The primary endpoint was the correlation of BP measurements between devices. Secondary endpoints included concordance between HBPM and cuffless pressures following a medication titration, and patient satisfaction with the cuffless device.</p><p><strong>Results: </strong>We enrolled 38 patients, of whom 25 provided BP data on overlapping dates with both devices. There was moderate correlation between average non-simultaneous daytime BPs within the same time periods (r=0.57, 95% CI: 0.39-0.71 for systolic BP [p<0.001]; r=0.64, 95% CI: 0.48-0.76, for diastolic BP [p<0.001]). The concordance of systolic BP changes detected by the two devices post-medication titration was 87.5%. Most patients (91%) preferred the cuffless device, citing ease of use and convenience.</p><p><strong>Conclusion: </strong>Cuffless BP devices demonstrate promise in enhancing patient compliance and effectiveness in HTN management. Their integration into clinical practice could offer a more patient-friendly and reliable approach to BP monitoring, though more research is needed to establish their utility in large populations.</p>","PeriodicalId":7578,"journal":{"name":"American Journal of Hypertension","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2025-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Hypertension","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajh/hpaf003","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Remote hypertension management programs have emerged as potential solutions to improve poor rates of blood pressure (BP) control. The Continual Versus Occasional Blood Pressure (COOL-BP) Study investigated the feasibility and efficacy of using a cuffless wrist BP monitor in a remote hypertension (HTN) program.

Methods: COOL-BP was a prospective single-arm study within a larger HTN management program at Mass General Brigham (MGB). Participants had uncontrolled HTN, were already engaged in the MGB Remote Hypertension Program, and used a smartphone. The study involved patients wearing the Aktiia cuffless wrist BP monitor and performing traditional home BP monitoring (HBPM). The primary endpoint was the correlation of BP measurements between devices. Secondary endpoints included concordance between HBPM and cuffless pressures following a medication titration, and patient satisfaction with the cuffless device.

Results: We enrolled 38 patients, of whom 25 provided BP data on overlapping dates with both devices. There was moderate correlation between average non-simultaneous daytime BPs within the same time periods (r=0.57, 95% CI: 0.39-0.71 for systolic BP [p<0.001]; r=0.64, 95% CI: 0.48-0.76, for diastolic BP [p<0.001]). The concordance of systolic BP changes detected by the two devices post-medication titration was 87.5%. Most patients (91%) preferred the cuffless device, citing ease of use and convenience.

Conclusion: Cuffless BP devices demonstrate promise in enhancing patient compliance and effectiveness in HTN management. Their integration into clinical practice could offer a more patient-friendly and reliable approach to BP monitoring, though more research is needed to establish their utility in large populations.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
American Journal of Hypertension
American Journal of Hypertension 医学-外周血管病
CiteScore
6.90
自引率
6.20%
发文量
144
审稿时长
3-8 weeks
期刊介绍: The American Journal of Hypertension is a monthly, peer-reviewed journal that provides a forum for scientific inquiry of the highest standards in the field of hypertension and related cardiovascular disease. The journal publishes high-quality original research and review articles on basic sciences, molecular biology, clinical and experimental hypertension, cardiology, epidemiology, pediatric hypertension, endocrinology, neurophysiology, and nephrology.
期刊最新文献
Continual Versus Occasional Blood Pressure (COOL-BP) in Remote Hypertension Management. Polo-like kinase 2 ameliorates lipopolysaccharide-induced cardiac injury by blocking cardiomyocyte ferroptosis. Ventricular-Arterial Coupling in Severe Aortic Stenosis: Implications for Prognosis. Clinical Inertia in the Diagnosis and Management of Hypertension Following Ambulatory Blood Pressure Monitoring. Systolic blood pressure modifies the effect of endovascular thrombectomy in acute ischemic stroke: a mediation analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1