Development of a Wearable Electromyographic Sensor with Aerosol Jet Printing Technology.

IF 3.7 3区 医学 Q2 ENGINEERING, BIOMEDICAL Bioengineering Pub Date : 2024-12-17 DOI:10.3390/bioengineering11121283
Stefano Perilli, Massimo Di Pietro, Emanuele Mantini, Martina Regazzetti, Pawel Kiper, Francesco Galliani, Massimo Panella, Dante Mantini
{"title":"Development of a Wearable Electromyographic Sensor with Aerosol Jet Printing Technology.","authors":"Stefano Perilli, Massimo Di Pietro, Emanuele Mantini, Martina Regazzetti, Pawel Kiper, Francesco Galliani, Massimo Panella, Dante Mantini","doi":"10.3390/bioengineering11121283","DOIUrl":null,"url":null,"abstract":"<p><p>Electromyographic (EMG) sensors are essential tools for analyzing muscle activity, but traditional designs often face challenges such as motion artifacts, signal variability, and limited wearability. This study introduces a novel EMG sensor fabricated using Aerosol Jet Printing (AJP) technology that addresses these limitations with a focus on precision, flexibility, and stability. The innovative sensor design minimizes air interposition at the skin-electrode interface, thereby reducing variability and improving signal quality. AJP enables the precise deposition of conductive materials onto flexible substrates, achieving a thinner and more conformable sensor that enhances user comfort and wearability. Performance testing compared the novel sensor to commercially available alternatives, highlighting its superior impedance stability across frequencies, even under mechanical stress. Physiological validation on a human participant confirmed the sensor's ability to accurately capture muscle activity during rest and voluntary contractions, with clear differentiation between low and high activity states. The findings highlight the sensor's potential for diverse applications, such as clinical diagnostics, rehabilitation, and sports performance monitoring. This work establishes AJP technology as a novel approach for designing wearable EMG sensors, providing a pathway for further advancements in miniaturization, strain-insensitive designs, and real-world deployment. Future research will explore optimization for broader applications and larger populations.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"11 12","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2024-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11673101/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11121283","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Electromyographic (EMG) sensors are essential tools for analyzing muscle activity, but traditional designs often face challenges such as motion artifacts, signal variability, and limited wearability. This study introduces a novel EMG sensor fabricated using Aerosol Jet Printing (AJP) technology that addresses these limitations with a focus on precision, flexibility, and stability. The innovative sensor design minimizes air interposition at the skin-electrode interface, thereby reducing variability and improving signal quality. AJP enables the precise deposition of conductive materials onto flexible substrates, achieving a thinner and more conformable sensor that enhances user comfort and wearability. Performance testing compared the novel sensor to commercially available alternatives, highlighting its superior impedance stability across frequencies, even under mechanical stress. Physiological validation on a human participant confirmed the sensor's ability to accurately capture muscle activity during rest and voluntary contractions, with clear differentiation between low and high activity states. The findings highlight the sensor's potential for diverse applications, such as clinical diagnostics, rehabilitation, and sports performance monitoring. This work establishes AJP technology as a novel approach for designing wearable EMG sensors, providing a pathway for further advancements in miniaturization, strain-insensitive designs, and real-world deployment. Future research will explore optimization for broader applications and larger populations.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于气溶胶喷射打印技术的可穿戴式肌电传感器的研制。
肌电图(EMG)传感器是分析肌肉活动的重要工具,但传统的设计经常面临运动伪影、信号变异性和有限的可穿戴性等挑战。本研究介绍了一种使用气溶胶喷射打印(AJP)技术制造的新型肌电传感器,该传感器解决了这些限制,重点是精度,灵活性和稳定性。创新的传感器设计最大限度地减少了皮肤电极界面的空气干扰,从而减少了可变性并提高了信号质量。AJP能够将导电材料精确地沉积到柔性基板上,从而实现更薄、更舒适的传感器,从而提高用户的舒适度和耐磨性。性能测试将新型传感器与市售替代品进行了比较,突出了其在不同频率下的优越阻抗稳定性,即使在机械应力下也是如此。人体参与者的生理验证证实了传感器在休息和自主收缩期间准确捕捉肌肉活动的能力,并明确区分了低活动状态和高活动状态。研究结果强调了传感器在多种应用领域的潜力,如临床诊断、康复和运动表现监测。这项工作确立了AJP技术作为一种设计可穿戴式肌电传感器的新方法,为进一步推进小型化、应变不敏感设计和实际部署提供了途径。未来的研究将为更广泛的应用和更大的人群探索优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Bioengineering
Bioengineering Chemical Engineering-Bioengineering
CiteScore
4.00
自引率
8.70%
发文量
661
期刊介绍: Aims Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal: ● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings. ● Manuscripts regarding research proposals and research ideas will be particularly welcomed. ● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material. ● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds. Scope ● Bionics and biological cybernetics: implantology; bio–abio interfaces ● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices ● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc. ● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology ● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering ● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation ● Translational bioengineering
期刊最新文献
PMR-Q&A: Development of a Bilingual Expert-Evaluated Question-Answer Dataset for Large Language Models in Physical Medicine and Rehabilitation. DyVarMap: Integrating Conformational Dynamics and Interpretable Machine Learning for Cancer-Associated Missense Variant Classification in FGFR2. Performance of Artificial Intelligence Models in Radiographic Image Analysis for Predicting Hip and Knee Prosthesis Failure: A Systematic Review. Automated Collateral Classification on CT Angiography in Acute Ischemic Stroke: Performance Trends Across Hyperparameter Combinations. Neuromuscular Evaluation in Orthodontic-Surgical Treatment: A Comparison Between Monomaxillary and Bimaxillary Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1