Consistency analysis of two US techniques for evaluating hepatic steatosis in patients with metabolic dysfunction-associated steatotic liver disease.

IF 2.9 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING BMC Medical Imaging Pub Date : 2025-01-07 DOI:10.1186/s12880-024-01549-1
Fei Chen, Jingjing An, Long Deng, Jing Wang, Ruiling He
{"title":"Consistency analysis of two US techniques for evaluating hepatic steatosis in patients with metabolic dysfunction-associated steatotic liver disease.","authors":"Fei Chen, Jingjing An, Long Deng, Jing Wang, Ruiling He","doi":"10.1186/s12880-024-01549-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>US tools to quantify hepatic steatosis have recently been made clinically available by different manufacturers, but comparative data on their consistency are lacking.</p><p><strong>Objective: </strong>US tools to quantify hepatic steatosis have recently been made clinically available by different manufacturers, but comparative data on their consistency are lacking. The aim of our study was to compare the diagnostic consistency for evaluating hepatic steatosis by two different US techniques, hepatorenal index by B-mode Ratio and attenuation coefficient by attenuation imaging (ATI).</p><p><strong>Methods: </strong>Patients with suspicion or previously diagnosed of metabolic dysfunction-associated steatotic liver disease (MASLD) who attended fatty liver consulting room from June 2023 to September 2023 were prospectively recruited. Patients underwent two different US techniques of B-mode Ratio and ATI, and laboratory test were collected. According to previously proposed cut-off values, B-mode Ratio ≥ 1.22, 1.42, 1.54, and ATI ≥ 0.62, 0.70, and 0.78 dB/cm/MH were used for assessing of mild, moderate, and severe hepatic steatosis, respectively. Kappa consistency test was used to evaluate the consistency of hepatic steatosis.</p><p><strong>Results: </strong>A total of 62 patients were enrolled, including 44 males (71.0%) with an age of (41 ± 13) years and a body mass index of (27.0 ± 3.5) kg/m<sup>2</sup>. In the hyperlipidemia group, the B-mode Ratio and ATI were significantly higher than those in the non-hyperlipidemia group, with values of 1.68 ± 0.39 vs. 1.28 ± 0.35 (p = 0.001) and 0.74 ± 0.12 dB/cm/MH vs. 0.64 ± 0.11 dB/cm/MH (p = 0.005), respectively. The correlation coefficient between B-mode Ratio and ATI was 0.732 (p < 0.001). Using B-mode Ratio and ATI as diagnostic criteria for MASLD, the proportion of patients with MASLD was 79% and 82%, respectively. The Kappa coefficient for assessing MASLD was 0.90 (p < 0.001). Furthermore, these two different US techniques were used for grading hepatic steatosis, with no, mild, moderate, and severe steatosis accounting for 21%, 18%, 13%, and 48%, as well as 18%, 29%, 22%, and 31%, respectively. The linear weighted Kappa coefficient for staging hepatic steatosis was 0.78 (95% confidence interval: 0.68-0.87, p < 0.001).</p><p><strong>Conclusion: </strong>The non-invasive methods of two different US techniques based on B-mode Ratio and ATI have good consistency for evaluating hepatic steatosis, and can be used for large-scale community screening.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"10"},"PeriodicalIF":2.9000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11708176/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-024-01549-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: US tools to quantify hepatic steatosis have recently been made clinically available by different manufacturers, but comparative data on their consistency are lacking.

Objective: US tools to quantify hepatic steatosis have recently been made clinically available by different manufacturers, but comparative data on their consistency are lacking. The aim of our study was to compare the diagnostic consistency for evaluating hepatic steatosis by two different US techniques, hepatorenal index by B-mode Ratio and attenuation coefficient by attenuation imaging (ATI).

Methods: Patients with suspicion or previously diagnosed of metabolic dysfunction-associated steatotic liver disease (MASLD) who attended fatty liver consulting room from June 2023 to September 2023 were prospectively recruited. Patients underwent two different US techniques of B-mode Ratio and ATI, and laboratory test were collected. According to previously proposed cut-off values, B-mode Ratio ≥ 1.22, 1.42, 1.54, and ATI ≥ 0.62, 0.70, and 0.78 dB/cm/MH were used for assessing of mild, moderate, and severe hepatic steatosis, respectively. Kappa consistency test was used to evaluate the consistency of hepatic steatosis.

Results: A total of 62 patients were enrolled, including 44 males (71.0%) with an age of (41 ± 13) years and a body mass index of (27.0 ± 3.5) kg/m2. In the hyperlipidemia group, the B-mode Ratio and ATI were significantly higher than those in the non-hyperlipidemia group, with values of 1.68 ± 0.39 vs. 1.28 ± 0.35 (p = 0.001) and 0.74 ± 0.12 dB/cm/MH vs. 0.64 ± 0.11 dB/cm/MH (p = 0.005), respectively. The correlation coefficient between B-mode Ratio and ATI was 0.732 (p < 0.001). Using B-mode Ratio and ATI as diagnostic criteria for MASLD, the proportion of patients with MASLD was 79% and 82%, respectively. The Kappa coefficient for assessing MASLD was 0.90 (p < 0.001). Furthermore, these two different US techniques were used for grading hepatic steatosis, with no, mild, moderate, and severe steatosis accounting for 21%, 18%, 13%, and 48%, as well as 18%, 29%, 22%, and 31%, respectively. The linear weighted Kappa coefficient for staging hepatic steatosis was 0.78 (95% confidence interval: 0.68-0.87, p < 0.001).

Conclusion: The non-invasive methods of two different US techniques based on B-mode Ratio and ATI have good consistency for evaluating hepatic steatosis, and can be used for large-scale community screening.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
期刊最新文献
High-risk habitat radiomics model based on ultrasound images for predicting lateral neck lymph node metastasis in differentiated thyroid cancer. Investigating resting-state functional connectivity changes within procedural memory network across neuropsychiatric disorders using fMRI. Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction. Comparison of diagnostic performance for pulmonary nodule detection between free-breathing spiral ultrashort echo time and free-breathing radial volumetric interpolated breath-hold examination. Knowledge discovery from database: MRI radiomic features to assess recurrence risk in high-grade meningiomas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1