{"title":"Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An <i>In Vitro</i> Study.","authors":"Abdulrahman Almalki, Noor Kutkut, Ramzi Althubaitiy, Ali Robaian, Khaled Alzaharni, Evanthia Anadioti","doi":"10.5005/jp-journals-10024-3752","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.</p><p><strong>Materials and methods: </strong>Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency. Occlusal contact forces were recorded using a T-scan III device with a pressure-mapping sensor. Maximum intercuspation (MIP) contact magnitudes were recorded by two calibrated examiners at 10-second intervals, ensuring reliable data collection across all conditions.</p><p><strong>Results: </strong>In MIP, tooth #9 consistently exhibited the highest contact percentages across all articulator conditions, with percentages of 22.2% in the new articulator, 21.8% in the short-term used articulators, and 21.5% in long-term used articulators, indicating stable contact force distribution. Tooth #12 consistently showed the lowest MIP contact percentages, suggesting minimal occlusal force in this region due to its absence. Contact forces, measured at 10-second intervals, showed no significant differences among the different articulator conditions in MIP (<i>p</i> > 0.01).</p><p><strong>Conclusion: </strong>Within the limitations of this <i>in vitro</i> study, the calibrated Stratos 300 semi-adjustable articulator maintained superior accuracy over time.</p><p><strong>Clinical significance: </strong>The study confirms that the calibrated Stratos 300 semi-adjustable articulators provide consistent and accurate occlusal measurements over time, regardless of their usage over time. How to cite this article: Almalki A, Kutkut N, Althubaitiy R, <i>et al.</i> Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An <i>In Vitro</i> Study. J Contemp Dent Pract 2024;25(9):869-872.</p>","PeriodicalId":35792,"journal":{"name":"Journal of Contemporary Dental Practice","volume":"25 9","pages":"869-872"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Dental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10024-3752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.

Materials and methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency. Occlusal contact forces were recorded using a T-scan III device with a pressure-mapping sensor. Maximum intercuspation (MIP) contact magnitudes were recorded by two calibrated examiners at 10-second intervals, ensuring reliable data collection across all conditions.

Results: In MIP, tooth #9 consistently exhibited the highest contact percentages across all articulator conditions, with percentages of 22.2% in the new articulator, 21.8% in the short-term used articulators, and 21.5% in long-term used articulators, indicating stable contact force distribution. Tooth #12 consistently showed the lowest MIP contact percentages, suggesting minimal occlusal force in this region due to its absence. Contact forces, measured at 10-second intervals, showed no significant differences among the different articulator conditions in MIP (p > 0.01).

Conclusion: Within the limitations of this in vitro study, the calibrated Stratos 300 semi-adjustable articulator maintained superior accuracy over time.

Clinical significance: The study confirms that the calibrated Stratos 300 semi-adjustable articulators provide consistent and accurate occlusal measurements over time, regardless of their usage over time. How to cite this article: Almalki A, Kutkut N, Althubaitiy R, et al. Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An In Vitro Study. J Contemp Dent Pract 2024;25(9):869-872.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
随时间使用的当代半可调节关节的互换性:一项体外研究。
目的:本研究的目的是探讨新获得的、短期使用的和长期使用的半可调节关节的互换性。材料和方法:将部分齿状上下颌弓金属类似物安装在12个半可调节的Stratos 300关节器上,根据使用时间分为三组:新的,短期使用(2年)的关节器。每个铰接器根据制造商的指导方针进行校准,以确保一致性。使用带压力图传感器的T-scan III设备记录咬合接触力。最大间歇(MIP)接触震级由两个校准的检查器每隔10秒记录一次,确保在所有条件下可靠的数据收集。结果:在MIP中,9号牙在所有咬合器条件下均表现出最高的接触率,其中新咬合器的接触率为22.2%,短期使用的比例为21.8%,长期使用的比例为21.5%,表明接触力分布稳定。12号牙始终显示最低的MIP接触百分比,这表明由于它的缺失,该区域的咬合力最小。接触力,每隔10秒测量一次,显示MIP不同关节状态之间无显著差异(p > 0.01)。结论:在这项体外研究的局限性内,校准后的Stratos 300半可调关节器随着时间的推移保持了优异的准确性。临床意义:该研究证实,校准后的Stratos 300半可调关节器无论使用时间如何,都能提供一致和准确的咬合测量。本文引用方式:Almalki A, Kutkut N, Althubaitiy R等。随时间使用的当代半可调节关节的互换性:一项体外研究。[J]现代医学学报;2009;25(9):869-872。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Contemporary Dental Practice
Journal of Contemporary Dental Practice Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
174
期刊介绍: The Journal of Contemporary Dental Practice (JCDP), is a peer-reviewed, open access MEDLINE indexed journal. The journal’s full text is available online at http://www.thejcdp.com. The journal allows free access (open access) to its contents. Articles with clinical relevance will be given preference for publication. The Journal publishes original research papers, review articles, rare and novel case reports, and clinical techniques. Manuscripts are invited from all specialties of dentistry i.e., conservative dentistry and endodontics, dentofacial orthopedics and orthodontics, oral medicine and radiology, oral pathology, oral surgery, orodental diseases, pediatric dentistry, implantology, periodontics, clinical aspects of public health dentistry, and prosthodontics.
期刊最新文献
Correlation of Serum Calcium and Vitamin D Levels in Patients with and without Periodontitis before and after Nonsurgical Periodontal Therapy. C-shaped Root Morphology with Four Canals in Mandibular First Molar: A Rare Case Report. Efficacy of a Biodegradable Dressing Containing Tranexamic Acid for Prevention of Alveolar Osteitis: A Randomized Clinical Trial. Evaluation of Effectiveness of Nanocrystalline Hydroxyapatite and Demineralized Bone Matrix Combined with Titanium-platelet Rich Fibrin for Ridge Preservation: A Randomized Controlled Clinical Trial. Evaluation of Glucose-6-Phosphate dehydrogenase in Saliva of Subjects with Normal Appearing Gingiva and Periodontitis using qRT-PCR: A Cross-sectional Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1