Adverse events of 20-22G second-generation endoscopic ultrasound-guided fine-needle biopsy needles for solid lesions in the upper gastrointestinal tract and adjacent organs: Systematic review and meta-analysis.

Cheng-Ye Pan, Shi-Min Wang, Dong-Hao Cai, Jia-Yi Ma, Shi-Yu Li, Yibin Guo, Sun Jing, Jin Zhendong, Kaixuan Wang
{"title":"Adverse events of 20-22G second-generation endoscopic ultrasound-guided fine-needle biopsy needles for solid lesions in the upper gastrointestinal tract and adjacent organs: Systematic review and meta-analysis.","authors":"Cheng-Ye Pan, Shi-Min Wang, Dong-Hao Cai, Jia-Yi Ma, Shi-Yu Li, Yibin Guo, Sun Jing, Jin Zhendong, Kaixuan Wang","doi":"10.1111/den.14972","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Previous research has conducted meta-analyses on the diagnostic accuracy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB). However, studies on adverse events (AEs) have been limited and sporadic and have included a highly diverse group of patients (with upper and lower gastrointestinal tract issues) and needles of varying sizes (19-22-25G). The purpose of this systematic review and meta-analysis was to determine the incidence of AEs related to the utilization of 20-22G second-generation EUS-FNB needles subsequent to puncture of the upper gastrointestinal tract and adjacent organs.</p><p><strong>Methods: </strong>We searched the PubMed, Embase, and SCIE databases from January 1, 2010, to December 31, 2023. The primary outcome was percentage of summary AEs. Subgroup analyses were based on needle type, needle size, and lesion site.</p><p><strong>Results: </strong>A total of 99 studies were included in the analysis, with 9303 patients. The overall AE rate for 20-22G second generation EUS-FNB needles in upper gastrointestinal EUS-FNB was 1.8% (166/9303), with bleeding being the most common AE at 44.0%. The percentages of pancreatitis, abdominal pain, and other AEs were 24.1%, 21.1%, and 10.8%, respectively. Patients undergoing hepatic EUS-FNB had the highest incidence of AEs at 14.0%, followed by submucosal lesions at 3.2% and pancreatic lesions at 2.6%.</p><p><strong>Conclusion: </strong>EUS-FNB is a safe procedure with a relatively low risk of upper gastrointestinal AEs (1.8%) and no associated deaths. Postoperative bleeding and pancreatitis are the most common complications of EUS-FNB. Most AEs are mild and self-limiting in severity, and serious complications are very rare.</p>","PeriodicalId":72813,"journal":{"name":"Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/den.14972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Previous research has conducted meta-analyses on the diagnostic accuracy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB). However, studies on adverse events (AEs) have been limited and sporadic and have included a highly diverse group of patients (with upper and lower gastrointestinal tract issues) and needles of varying sizes (19-22-25G). The purpose of this systematic review and meta-analysis was to determine the incidence of AEs related to the utilization of 20-22G second-generation EUS-FNB needles subsequent to puncture of the upper gastrointestinal tract and adjacent organs.

Methods: We searched the PubMed, Embase, and SCIE databases from January 1, 2010, to December 31, 2023. The primary outcome was percentage of summary AEs. Subgroup analyses were based on needle type, needle size, and lesion site.

Results: A total of 99 studies were included in the analysis, with 9303 patients. The overall AE rate for 20-22G second generation EUS-FNB needles in upper gastrointestinal EUS-FNB was 1.8% (166/9303), with bleeding being the most common AE at 44.0%. The percentages of pancreatitis, abdominal pain, and other AEs were 24.1%, 21.1%, and 10.8%, respectively. Patients undergoing hepatic EUS-FNB had the highest incidence of AEs at 14.0%, followed by submucosal lesions at 3.2% and pancreatic lesions at 2.6%.

Conclusion: EUS-FNB is a safe procedure with a relatively low risk of upper gastrointestinal AEs (1.8%) and no associated deaths. Postoperative bleeding and pancreatitis are the most common complications of EUS-FNB. Most AEs are mild and self-limiting in severity, and serious complications are very rare.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
20-22G第二代超声内镜引导下细针活检针用于上消化道及邻近器官实性病变的不良事件:系统回顾和荟萃分析。
目的:以往的研究对内镜超声引导下细针活检(EUS-FNB)的诊断准确性进行了荟萃分析。然而,关于不良事件(ae)的研究是有限的和零星的,并且包括高度多样化的患者组(上消化道和下消化道问题)和不同大小的针头(19-22-25G)。本系统综述和荟萃分析的目的是确定使用20-22G第二代EUS-FNB针穿刺上胃肠道和邻近器官后发生ae的相关发生率。方法:检索PubMed、Embase和SCIE数据库,检索时间为2010年1月1日至2023年12月31日。主要终点是总ae的百分比。亚组分析基于针的类型、针的大小和病变部位。结果:共纳入99项研究,9303例患者。20-22G第二代EUS-FNB针用于上消化道EUS-FNB的总体AE发生率为1.8%(166/9303),其中出血是最常见的AE,发生率为44.0%。胰腺炎、腹痛和其他不良事件发生率分别为24.1%、21.1%和10.8%。肝脏EUS-FNB患者ae发生率最高,为14.0%,其次是粘膜下病变(3.2%)和胰腺病变(2.6%)。结论:EUS-FNB是一种安全的手术,上消化道不良事件的风险相对较低(1.8%),无相关死亡。术后出血和胰腺炎是EUS-FNB最常见的并发症。大多数ae的严重程度为轻度和自限性,严重的并发症非常罕见。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Three-dimensional optically cleared tissue imaging for analyzing endoscopic images of gastrointestinal neoplasms (with video). Endoscopic sleeve gastroplasty - Current status and future perspectives. Usefulness of novel line traction-assisted polypectomy for a large gastric polyp prolapsing into the duodenum. Spectrum of gastric neoplasms in Helicobacter pylori-naïve patients. Closure method to prevent leakages from perforations using multiple over-the-scope clips in an over-the-line method.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1