Importance of neural network complexity for the automatic segmentation of individual thigh muscles in MRI images from patients with neuromuscular diseases.
Sandra Martin, Rémi André, Amira Trabelsi, Constance P Michel, Etienne Fortanier, Shahram Attarian, Maxime Guye, Marc Dubois, Redha Abdeddaim, David Bendahan
{"title":"Importance of neural network complexity for the automatic segmentation of individual thigh muscles in MRI images from patients with neuromuscular diseases.","authors":"Sandra Martin, Rémi André, Amira Trabelsi, Constance P Michel, Etienne Fortanier, Shahram Attarian, Maxime Guye, Marc Dubois, Redha Abdeddaim, David Bendahan","doi":"10.1007/s10334-024-01221-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Segmentation of individual thigh muscles in MRI images is essential for monitoring neuromuscular diseases and quantifying relevant biomarkers such as fat fraction (FF). Deep learning approaches such as U-Net have demonstrated effectiveness in this field. However, the impact of reducing neural network complexity remains unexplored in the FF quantification in individual muscles.</p><p><strong>Material and methods: </strong>U-Net architectures with different complexities have been compared for the quantification of the fat fraction in each muscle group selected in the central part of the thigh region. The corresponding performance has been assessed in terms of Dice score (DSC) and FF quantification error. The database contained 1450 thigh images from 59 patients and 14 healthy subjects (age: 47 ± 17 years, sex: 36F, 37M). Ten individual muscles were segmented in each image. The performance of each model was compared to nnU-Net, a complex architecture with 4.35 <math><mo>×</mo></math> 10<sup>7</sup> parameters, 12.8 Gigabytes of peak memory usage and 167 h of training time.</p><p><strong>Results: </strong>As expected, nnU-Net achieved the highest DSC (94.77 ± 0.13%). A simpler U-Net (5.81 <math><mo>×</mo></math> 10<sup>5</sup> parameters, 2.37 Gigabytes, 14 h of training time) achieved a lower DSC but still above 90%. Surprisingly, both models achieved a comparable FF estimation.</p><p><strong>Discussion: </strong>The poor correlation between observed DSC and FF indicates that less complex architectures, reducing GPU memory utilization and training time, can still accurately quantify FF.</p>","PeriodicalId":18067,"journal":{"name":"Magnetic Resonance Materials in Physics, Biology and Medicine","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance Materials in Physics, Biology and Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10334-024-01221-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Segmentation of individual thigh muscles in MRI images is essential for monitoring neuromuscular diseases and quantifying relevant biomarkers such as fat fraction (FF). Deep learning approaches such as U-Net have demonstrated effectiveness in this field. However, the impact of reducing neural network complexity remains unexplored in the FF quantification in individual muscles.
Material and methods: U-Net architectures with different complexities have been compared for the quantification of the fat fraction in each muscle group selected in the central part of the thigh region. The corresponding performance has been assessed in terms of Dice score (DSC) and FF quantification error. The database contained 1450 thigh images from 59 patients and 14 healthy subjects (age: 47 ± 17 years, sex: 36F, 37M). Ten individual muscles were segmented in each image. The performance of each model was compared to nnU-Net, a complex architecture with 4.35 107 parameters, 12.8 Gigabytes of peak memory usage and 167 h of training time.
Results: As expected, nnU-Net achieved the highest DSC (94.77 ± 0.13%). A simpler U-Net (5.81 105 parameters, 2.37 Gigabytes, 14 h of training time) achieved a lower DSC but still above 90%. Surprisingly, both models achieved a comparable FF estimation.
Discussion: The poor correlation between observed DSC and FF indicates that less complex architectures, reducing GPU memory utilization and training time, can still accurately quantify FF.
期刊介绍:
MAGMA is a multidisciplinary international journal devoted to the publication of articles on all aspects of magnetic resonance techniques and their applications in medicine and biology. MAGMA currently publishes research papers, reviews, letters to the editor, and commentaries, six times a year. The subject areas covered by MAGMA include:
advances in materials, hardware and software in magnetic resonance technology,
new developments and results in research and practical applications of magnetic resonance imaging and spectroscopy related to biology and medicine,
study of animal models and intact cells using magnetic resonance,
reports of clinical trials on humans and clinical validation of magnetic resonance protocols.