A highly sensitive creatine kinase detection in human serum using 11-mercaptoundecanoic acid modified ITO-PET electrodes

IF 2.6 4区 生物学 Q2 BIOCHEMICAL RESEARCH METHODS Analytical biochemistry Pub Date : 2025-01-10 DOI:10.1016/j.ab.2025.115768
Burçak Demirbakan
{"title":"A highly sensitive creatine kinase detection in human serum using 11-mercaptoundecanoic acid modified ITO-PET electrodes","authors":"Burçak Demirbakan","doi":"10.1016/j.ab.2025.115768","DOIUrl":null,"url":null,"abstract":"<div><div>The enzyme creatine kinase (CK) is a biomarker that plays an extremely significant role in the early detection of cardiovascular disorders. Serum levels of CK are regularly monitored in patients with heart attacks, one of the most critical cardiovascular illnesses. In this study, a highly sensitive electrochemical immunosensor system was designed for the importance of early diagnosis of CK. This immunosensor system was developed by immobilizing 11- mercaptoundecanoic acid (11-MuA) on disposable indium tin oxide–polyethylene terephthalate (ITO-PET) electrodes. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and single frequency impedance (SFI) techniques were utilized throughout the immobilization process during the construction of the immunosensor. In addition, the proposed CK immunosensor system involves thorough analytical research, which may include linear determination range, repeatability, reproducibility, square wave voltammetry, storage capability, and regeneration. The suggested immunosensor was also characterized using scanning electron microscopy (SEM). The proposed immunosensor system demonstrated a broad dynamic range (0.1 pg/mL – 100 pg/mL), as well as a low limit of detection (LOD) and a low limit of quantification (LOQ) of 0.018 pg/mL and 0.0394 pg/mL, respectively. Finally, the immunosensor was tested on human serum samples, proving that it could be utilized in clinical situations.</div></div>","PeriodicalId":7830,"journal":{"name":"Analytical biochemistry","volume":"700 ","pages":"Article 115768"},"PeriodicalIF":2.6000,"publicationDate":"2025-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical biochemistry","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003269725000053","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The enzyme creatine kinase (CK) is a biomarker that plays an extremely significant role in the early detection of cardiovascular disorders. Serum levels of CK are regularly monitored in patients with heart attacks, one of the most critical cardiovascular illnesses. In this study, a highly sensitive electrochemical immunosensor system was designed for the importance of early diagnosis of CK. This immunosensor system was developed by immobilizing 11- mercaptoundecanoic acid (11-MuA) on disposable indium tin oxide–polyethylene terephthalate (ITO-PET) electrodes. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and single frequency impedance (SFI) techniques were utilized throughout the immobilization process during the construction of the immunosensor. In addition, the proposed CK immunosensor system involves thorough analytical research, which may include linear determination range, repeatability, reproducibility, square wave voltammetry, storage capability, and regeneration. The suggested immunosensor was also characterized using scanning electron microscopy (SEM). The proposed immunosensor system demonstrated a broad dynamic range (0.1 pg/mL – 100 pg/mL), as well as a low limit of detection (LOD) and a low limit of quantification (LOQ) of 0.018 pg/mL and 0.0394 pg/mL, respectively. Finally, the immunosensor was tested on human serum samples, proving that it could be utilized in clinical situations.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用11-巯基十四酸修饰ITO-PET电极检测人血清中高灵敏度肌酸激酶。
肌酸激酶(CK)是一种生物标志物,在心血管疾病的早期检测中起着极其重要的作用。心脏病是最严重的心血管疾病之一,在心脏病患者中,血清CK水平被定期监测。鉴于早期诊断CK的重要性,本研究设计了一种高灵敏度的电化学免疫传感器系统。该免疫传感器系统是通过将11-巯基十四酸(11- mua)固定在一次性氧化铟锡-聚对苯二甲酸乙二醇酯(ITO-PET)电极上开发的。在构建免疫传感器的整个固定过程中,采用了电化学阻抗谱(EIS)、循环伏安法(CV)和单频阻抗(SFI)技术。此外,拟议的CK免疫传感器系统涉及深入的分析研究,其中可能包括线性测定范围,可重复性,再现性,方波伏安法,存储能力和再生。所提出的免疫传感器也用扫描电镜(SEM)进行了表征。该免疫传感器系统具有较宽的动态范围(0.1 pg mL-1 ~ 100 pg mL-1),低检测限(LOD)和低定量限(LOQ)分别为0.018 pg mL-1和0.0394 pg mL-1。最后,对人体血清样本进行了测试,证明该免疫传感器可用于临床。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical biochemistry
Analytical biochemistry 生物-分析化学
CiteScore
5.70
自引率
0.00%
发文量
283
审稿时长
44 days
期刊介绍: The journal''s title Analytical Biochemistry: Methods in the Biological Sciences declares its broad scope: methods for the basic biological sciences that include biochemistry, molecular genetics, cell biology, proteomics, immunology, bioinformatics and wherever the frontiers of research take the field. The emphasis is on methods from the strictly analytical to the more preparative that would include novel approaches to protein purification as well as improvements in cell and organ culture. The actual techniques are equally inclusive ranging from aptamers to zymology. The journal has been particularly active in: -Analytical techniques for biological molecules- Aptamer selection and utilization- Biosensors- Chromatography- Cloning, sequencing and mutagenesis- Electrochemical methods- Electrophoresis- Enzyme characterization methods- Immunological approaches- Mass spectrometry of proteins and nucleic acids- Metabolomics- Nano level techniques- Optical spectroscopy in all its forms. The journal is reluctant to include most drug and strictly clinical studies as there are more suitable publication platforms for these types of papers.
期刊最新文献
Olive leaf as a functional cosmetic ingredient and analysis of the principal component Aptasensor based on rGO-AuNPs Field-effect Transistor for selective detection of Escherichia coli in river water An overview of biosensor advancements for detecting botulinum neurotoxins: addressing food safety and biowarfare risks. In-depth characterization and semi-quantification of anti-drug antibodies in clinical samples using specific hybrid IC-LC-MS/MS methods. Quantification of amyloid-β aggregation inhibitors gallic acid and rosmarinic acid in biological samples by LC-MS/MS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1