Quantitative Analysis of Hepatitis D Virus Using gRNA-Sensitive Semiconducting Polymer Dots

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL Analytical Chemistry Pub Date : 2025-01-14 DOI:10.1021/acs.analchem.4c04147
Ze Zhang, Yuyang Wu, Jinglun Xu, Zihui Meng, Qingmin Chen, Shengyan Yin
{"title":"Quantitative Analysis of Hepatitis D Virus Using gRNA-Sensitive Semiconducting Polymer Dots","authors":"Ze Zhang, Yuyang Wu, Jinglun Xu, Zihui Meng, Qingmin Chen, Shengyan Yin","doi":"10.1021/acs.analchem.4c04147","DOIUrl":null,"url":null,"abstract":"Hepatitis D virus (HDV) significantly influences the progression of liver diseases. Through clinical observations and database analyses, it has been established that patients coinfected with HDV and hepatitis B virus (HBV) experience accelerated progression toward cirrhosis, hepatocellular carcinoma (HCC), and liver failure compared to those infected solely with HBV. A higher viral load correlates with increased replicative activity, enhanced infectivity, and more severe disease manifestations. In this study, we use HDV gRNA-sensitive semiconducting polymer dots (Pdots) as the nanoprobes for the quantitative analysis of HDV copy number variations. The surface of the Pdots is engineered with a clamp design that includes a pair of reporter sequences, protection sequences, and capture sequences tailored to the conserved sequence length of the HDV genome. The capture sequence, comprising leading and trailing chains, specifically binds to the gRNA of the target virus. The protection sequence shields the Pdots from external interference, while the reporter sequence detects the presence of target gRNA through the degradation of fluorescent dye Cy5.5dt. We demonstrate the effectiveness of this assay in a stably transfected cell line derived from HepG2-HDV cells and its translational application in clinical samples from patients. Additionally, this nanobiosensor can accurately detect gRNA at femtomolar (fM) levels, a sensitivity unachievable by previously reported methods. This novel virus quantification system offers significant potential for clinical and virological applications, enhancing screening, early diagnosis, and personalized treatment strategies.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"22 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c04147","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Hepatitis D virus (HDV) significantly influences the progression of liver diseases. Through clinical observations and database analyses, it has been established that patients coinfected with HDV and hepatitis B virus (HBV) experience accelerated progression toward cirrhosis, hepatocellular carcinoma (HCC), and liver failure compared to those infected solely with HBV. A higher viral load correlates with increased replicative activity, enhanced infectivity, and more severe disease manifestations. In this study, we use HDV gRNA-sensitive semiconducting polymer dots (Pdots) as the nanoprobes for the quantitative analysis of HDV copy number variations. The surface of the Pdots is engineered with a clamp design that includes a pair of reporter sequences, protection sequences, and capture sequences tailored to the conserved sequence length of the HDV genome. The capture sequence, comprising leading and trailing chains, specifically binds to the gRNA of the target virus. The protection sequence shields the Pdots from external interference, while the reporter sequence detects the presence of target gRNA through the degradation of fluorescent dye Cy5.5dt. We demonstrate the effectiveness of this assay in a stably transfected cell line derived from HepG2-HDV cells and its translational application in clinical samples from patients. Additionally, this nanobiosensor can accurately detect gRNA at femtomolar (fM) levels, a sensitivity unachievable by previously reported methods. This novel virus quantification system offers significant potential for clinical and virological applications, enhancing screening, early diagnosis, and personalized treatment strategies.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
期刊最新文献
Your Blood is Out for Delivery: Considerations of Shipping Time and Temperature on Degradation of RNA from Stabilized Whole Blood Two-Step Acoustic Cell Separation Based on Cell Size and Acoustic Impedance─toward Isolation of Viable Circulating Tumor Cells NIRFluor: A Deep Learning Platform for Rapid Screening of Small Molecule Near-Infrared Fluorophores with Desired Optical Properties Integrating C–H Information to Improve Machine Learning Classification Models for Microplastic Identification from Raman Spectra A Dual-Mode Colorimetric and Fluorescence Biosensor Based on a Nucleic Acid Multiplexing Platform for the Detection of Listeria monocytogenes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1