Total-Body PET System Designs with Axial and Transverse Gaps: A Study of Lesion Quantification and Detectability

Min Gao, Margaret E. Daube-Witherspoon, Joel S. Karp, Suleman Surti
{"title":"Total-Body PET System Designs with Axial and Transverse Gaps: A Study of Lesion Quantification and Detectability","authors":"Min Gao, Margaret E. Daube-Witherspoon, Joel S. Karp, Suleman Surti","doi":"10.2967/jnumed.124.267769","DOIUrl":null,"url":null,"abstract":"<p>High-sensitivity total-body PET enables faster scans, lower doses, and dynamic multiorgan imaging. However, the higher system cost of a scanner with a long axial field of view (AFOV) hinders its wider application. This paper investigates the impact on the lesion quantification and detectability of cost-effective total-body PET sparse designs. <strong>Methods:</strong> Using the PennPET Explorer (PPEx) as a model, 3 sparse configurations with the same 142-cm AFOV were considered, including designs with only axial gaps (AGs), only transverse gaps (TGs), and a mixture of AGs and TGs (MG), with retained detector fractions (DFs) ranging from 71% to 40%. Human data from the PPEx were used to emulate sparse designs by discarding lines of response as a proxy for missing detectors. We embedded lesion events in the resultant list data with varying uptakes in the lung and liver before reconstruction. A generalized scan statistics methodology was used to measure lesion detectability and quantification as a function of lesion uptake and scan duration. <strong>Results:</strong> Relative to a fully populated system, an AG design with 71% performs well but is susceptible to image artifacts as the DF decreases to 58%. A TG design performs well with a DF of 58% but requires twice the scan time to achieve similar lesion detectability and is susceptible to transverse field-of-view truncation below 60 cm as the DF is further decreased. An MG design with a DF of 58% requires 3 times the scan time to achieve similar lesion detectability, and with no evidence of artifacts even as the DF is decreased to 40%. <strong>Conclusion:</strong> Sparse designs with artifact-free images can provide comparable lesion quantification and detectability to the fully populated PPEx after compensating for the reduced sensitivity with increased scan time. Because an AG design is more susceptible to image artifacts with a lower DF, a system with only AGs is not an optimal choice for dramatic cost reduction. A TG design provides a higher relative sensitivity than AG or MG designs for a given DF, leading to a shorter scan time to achieve comparable lesion detectability. However, the increased truncation of the transverse field of view with decreasing DF limits this design choice. An MG design allows for the greatest cost reduction (lowest DF) if the scan duration is increased to compensate for the higher loss in sensitivity. Sparse designs of PET with a long AFOV provide a technologic solution for introducing such systems at reduced cost into routine clinical use.</p>","PeriodicalId":22820,"journal":{"name":"The Journal of Nuclear Medicine","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnumed.124.267769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

High-sensitivity total-body PET enables faster scans, lower doses, and dynamic multiorgan imaging. However, the higher system cost of a scanner with a long axial field of view (AFOV) hinders its wider application. This paper investigates the impact on the lesion quantification and detectability of cost-effective total-body PET sparse designs. Methods: Using the PennPET Explorer (PPEx) as a model, 3 sparse configurations with the same 142-cm AFOV were considered, including designs with only axial gaps (AGs), only transverse gaps (TGs), and a mixture of AGs and TGs (MG), with retained detector fractions (DFs) ranging from 71% to 40%. Human data from the PPEx were used to emulate sparse designs by discarding lines of response as a proxy for missing detectors. We embedded lesion events in the resultant list data with varying uptakes in the lung and liver before reconstruction. A generalized scan statistics methodology was used to measure lesion detectability and quantification as a function of lesion uptake and scan duration. Results: Relative to a fully populated system, an AG design with 71% performs well but is susceptible to image artifacts as the DF decreases to 58%. A TG design performs well with a DF of 58% but requires twice the scan time to achieve similar lesion detectability and is susceptible to transverse field-of-view truncation below 60 cm as the DF is further decreased. An MG design with a DF of 58% requires 3 times the scan time to achieve similar lesion detectability, and with no evidence of artifacts even as the DF is decreased to 40%. Conclusion: Sparse designs with artifact-free images can provide comparable lesion quantification and detectability to the fully populated PPEx after compensating for the reduced sensitivity with increased scan time. Because an AG design is more susceptible to image artifacts with a lower DF, a system with only AGs is not an optimal choice for dramatic cost reduction. A TG design provides a higher relative sensitivity than AG or MG designs for a given DF, leading to a shorter scan time to achieve comparable lesion detectability. However, the increased truncation of the transverse field of view with decreasing DF limits this design choice. An MG design allows for the greatest cost reduction (lowest DF) if the scan duration is increased to compensate for the higher loss in sensitivity. Sparse designs of PET with a long AFOV provide a technologic solution for introducing such systems at reduced cost into routine clinical use.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
带有轴向和横向间隙的全身 PET 系统设计:病变定量和可探测性研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Total-Body PET System Designs with Axial and Transverse Gaps: A Study of Lesion Quantification and Detectability Large Language Models and Large Multimodal Models in Medical Imaging: A Primer for Physicians Imaging Demyelinated Axons After Spinal Cord Injuries with PET Tracer [18F]3F4AP PET-Based Risk Stratification in Primary Mediastinal B-Cell Lymphoma: A Comparative Analysis of Different Segmentation Methods in the IELSG37 Trial Patient Cohort Comprehensive Characterization via Molecular Imaging, Longitudinal Multisite Sampling, and Autoptic Work-up in Advanced Small Cell Lung Cancer Undergoing SSTR-Directed Radiopharmaceutical Therapy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1