A novel LC-TQ-MS/MS method for quantifying mefenamic acid-NDSRI (N-nitroso drug substance-related impurity) in mefenamic acid tablet and pediatric suspension dosage forms: a comparative study with a cost-effective white, green, and blue UPLC method†

IF 4.6 3区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY RSC Advances Pub Date : 2025-01-21 DOI:10.1039/D4RA08425J
Srinivas Nakka, Naresh Kumar Katari, Siva Krishna Muchakayala, Sreekantha Babu Jonnalagadda and Surendra Babu Manabolu Surya
{"title":"A novel LC-TQ-MS/MS method for quantifying mefenamic acid-NDSRI (N-nitroso drug substance-related impurity) in mefenamic acid tablet and pediatric suspension dosage forms: a comparative study with a cost-effective white, green, and blue UPLC method†","authors":"Srinivas Nakka, Naresh Kumar Katari, Siva Krishna Muchakayala, Sreekantha Babu Jonnalagadda and Surendra Babu Manabolu Surya","doi":"10.1039/D4RA08425J","DOIUrl":null,"url":null,"abstract":"<p >The current research presents novel LC-TQ-MS/MS and cost-effective UPLC methods intended for the accurate quantification of mefenamic acid-N-nitroso drug substance-related impurity-NDSRI (N-MFA) in mefenamic acid (MFA) tablet and pediatric suspension dosage forms. The acceptable intake of N-MFA is derived from the TD50 (Median Toxic Dose-50%) value of N-nitroso diphenylamine. The analytical separation was achieved for the UPLC method using an XBridge BEH Shield RP18 Column (150 × 3.0 mm, 3.5 μm), employing 0.1% formic acid and acetonitrile as mobile phases in a gradient mode. A flow rate of 0.7 mL min<small><sup>−1</sup></small> was set for the pump, and the detection wavelength was 230 nm. LC-TQ-MS-MS analysis was accomplished utilizing a Xevo TQ-XS mass spectrometer with electrospray ionization in the positive mode. N-MFA quantification was carried out using multiple reaction monitoring (MRM) as the mass transition: <em>m</em>/<em>z</em> 271.13 → 241.14. The proposed methods were successfully validated following ICH guidelines and are capable of quantifying at 0.01 ng mL<small><sup>−1</sup></small> at an MFA concentration of 1 mg mL<small><sup>−1</sup></small> for the LC-MS/MS method and at 0.036 μg mL<small><sup>−1</sup></small> at an MFA concentration of 10 mg mL<small><sup>−1</sup></small> for UPLC. The validated methods exhibited excellent linearity over the concentration ranges of 0.01 to 125 ppm for LC-MS/MS and 0.036 μg mL<small><sup>−1</sup></small> to 1.250 μg mL<small><sup>−1</sup></small> (3.6 to 125 ppm) for UPLC, with a Pearson correlation coefficient of 0.999. The method's trueness, in terms of accuracy recoveries, ranged from 90.43% to 101.34% for LC-MS/MS and 92.12% to 101.21% for UPLC. The applicability of these methods was successfully verified through the analysis of commercial samples of MFA formulations. Additionally, the sustainability and eco-friendliness of the method were assessed using whiteness and greenness metrics, including RGB12 (Red-Gree-Blue) tools, GAPI (Green Analytical Procedure Index), analytical eco-scale, AGREE (Analytical GREEnness), AGREEprep (Analytical GREEnnesspreparation), and BAGI (Blue Applicability Grade Index). Both methods can be used to determine N-MFA content in mefenamic acid formulation dosage based on the availability of instruments LC-TQ-MS/MS and UPLC in R&amp;D (Research and Development) and quality control laboratories.</p>","PeriodicalId":102,"journal":{"name":"RSC Advances","volume":" 3","pages":" 1957-1969"},"PeriodicalIF":4.6000,"publicationDate":"2025-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2025/ra/d4ra08425j?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RSC Advances","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ra/d4ra08425j","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The current research presents novel LC-TQ-MS/MS and cost-effective UPLC methods intended for the accurate quantification of mefenamic acid-N-nitroso drug substance-related impurity-NDSRI (N-MFA) in mefenamic acid (MFA) tablet and pediatric suspension dosage forms. The acceptable intake of N-MFA is derived from the TD50 (Median Toxic Dose-50%) value of N-nitroso diphenylamine. The analytical separation was achieved for the UPLC method using an XBridge BEH Shield RP18 Column (150 × 3.0 mm, 3.5 μm), employing 0.1% formic acid and acetonitrile as mobile phases in a gradient mode. A flow rate of 0.7 mL min−1 was set for the pump, and the detection wavelength was 230 nm. LC-TQ-MS-MS analysis was accomplished utilizing a Xevo TQ-XS mass spectrometer with electrospray ionization in the positive mode. N-MFA quantification was carried out using multiple reaction monitoring (MRM) as the mass transition: m/z 271.13 → 241.14. The proposed methods were successfully validated following ICH guidelines and are capable of quantifying at 0.01 ng mL−1 at an MFA concentration of 1 mg mL−1 for the LC-MS/MS method and at 0.036 μg mL−1 at an MFA concentration of 10 mg mL−1 for UPLC. The validated methods exhibited excellent linearity over the concentration ranges of 0.01 to 125 ppm for LC-MS/MS and 0.036 μg mL−1 to 1.250 μg mL−1 (3.6 to 125 ppm) for UPLC, with a Pearson correlation coefficient of 0.999. The method's trueness, in terms of accuracy recoveries, ranged from 90.43% to 101.34% for LC-MS/MS and 92.12% to 101.21% for UPLC. The applicability of these methods was successfully verified through the analysis of commercial samples of MFA formulations. Additionally, the sustainability and eco-friendliness of the method were assessed using whiteness and greenness metrics, including RGB12 (Red-Gree-Blue) tools, GAPI (Green Analytical Procedure Index), analytical eco-scale, AGREE (Analytical GREEnness), AGREEprep (Analytical GREEnnesspreparation), and BAGI (Blue Applicability Grade Index). Both methods can be used to determine N-MFA content in mefenamic acid formulation dosage based on the availability of instruments LC-TQ-MS/MS and UPLC in R&D (Research and Development) and quality control laboratories.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型LC-TQ-MS/MS法测定甲氧胺酸片剂和小儿混悬剂剂型中n -亚硝基原料药相关杂质(ndsri):与性价比高的白色、绿色和蓝色UPLC法的比较研究
本研究提出了一种新的LC-TQ-MS/MS和高性价比的UPLC方法,用于准确定量甲氧胺酸(MFA)片剂和儿科混悬剂剂型中甲氧胺酸-n -亚硝基原料药相关杂质- ndsri (N-MFA)。N-MFA的可接受摄入量来源于n -亚硝基二苯胺的TD50(中位毒性剂量-50%)值。采用XBridge BEH Shield RP18色谱柱(150 × 3.0 mm, 3.5 μm),以0.1%甲酸和乙腈为流动相,以梯度模式进行分析分离。泵的流速为0.7 mL min - 1,检测波长为230 nm。LC-TQ-MS-MS分析采用Xevo TQ-XS质谱仪,电喷雾电离模式为正模式。N-MFA定量采用多反应监测(MRM)作为质量跃迁:m/z 271.13→241.14。根据ICH指南成功验证了所提出的方法,并且能够在LC-MS/MS方法中以0.01 ng mL−1的MFA浓度为1 mg mL−1,在0.036 μ mL−1的MFA浓度为10 mg mL−1的UPLC中进行定量。验证的方法在LC-MS/MS的浓度范围为0.01 ~ 125 ppm, UPLC的浓度范围为0.036 ~ 1.250 μg mL - 1 (3.6 ~ 125 ppm), Pearson相关系数为0.999。LC-MS/MS和UPLC的回收率分别为90.43% ~ 101.34%和92.12% ~ 101.21%。通过对MFA配方商业样品的分析,成功地验证了这些方法的适用性。此外,使用白度和绿度指标评估该方法的可持续性和生态友好性,包括RGB12(红-绿-蓝)工具、GAPI(绿色分析程序指数)、分析生态尺度、AGREE(分析绿色)、AGREEprep(分析绿色准备)和BAGI(蓝色适用性等级指数)。两种方法均可用于甲胺酸制剂剂量中N-MFA含量的测定,基于研发和质控实验室LC-TQ-MS/MS和UPLC的可用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
RSC Advances
RSC Advances chemical sciences-
CiteScore
7.50
自引率
2.60%
发文量
3116
审稿时长
1.6 months
期刊介绍: An international, peer-reviewed journal covering all of the chemical sciences, including multidisciplinary and emerging areas. RSC Advances is a gold open access journal allowing researchers free access to research articles, and offering an affordable open access publishing option for authors around the world.
期刊最新文献
Comprehensive assessment of precious metal concentration, distribution, and recovery potential in municipal solid waste incineration residues from northern Vietnam Lincomycin HCl-loaded nanoparticles: development, optimization, and incorporation into a nanogel for wound healing Molecular mechanism of biocompatible clusteroluminogens from citric acid and l-lysine Tailoring carbon shell thickness in graphene–Li2S–carbon nanocomposite cathodes for enhanced polysulfide control and electrochemical stability Novel Ag-modified zirconia nanomaterials with antibacterial activity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1