Medical student training with next-generation handheld ultrasound devices - hands on examination of fetal biometry in obstetrics.

IF 2.7 2区 医学 Q1 EDUCATION & EDUCATIONAL RESEARCH BMC Medical Education Pub Date : 2025-01-22 DOI:10.1186/s12909-025-06683-0
Ruben Plöger, Julia Matschl, Adeline Walter, Ulrich Gembruch, Brigitte Strizek, Charlotte Behning, Agnes Wittek, Florian Recker
{"title":"Medical student training with next-generation handheld ultrasound devices - hands on examination of fetal biometry in obstetrics.","authors":"Ruben Plöger, Julia Matschl, Adeline Walter, Ulrich Gembruch, Brigitte Strizek, Charlotte Behning, Agnes Wittek, Florian Recker","doi":"10.1186/s12909-025-06683-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The technical development of ultrasound devices based on silicon chips has revolutionized ultrasound examinations, leading to the implementation of these portable handheld devices (PUD) in different medical fields. However, training on these devices is necessary to assure appropriate use and ensure valid results. While training programs for the use of conventional standard ultrasound devices (SUD) have been described, no training program for these handheld devices has been developed thus far.</p><p><strong>Methods: </strong>A training program for obstetric ultrasound examination was modified through the addition of an extra module focusing on the use of these PUDs. After the module the students had to attend an OSCE in which their skills of using the PUD and the SUD were tested and analyzed by applying the agreement rate, the intraclass correlation coefficient (ICC) and Bland-Altman plots. Furthermore, the students' ultrasound results were compared with those of trained physicians by employing the one-sample Student's t-test. After the OSCE, the students answered a survey regarding their experience and their expected use of these devices.</p><p><strong>Result: </strong>An agreement of one hundred percent was reached for basic parameters such as fetal position, placental position, fetal heartbeat and for the classification of the amniotic fluid. The ICC showed a good to moderate agreement between the results of fetal biometry achieved by SUD and PUD. The T-test results confirmed a high reliability between the physicians' results and the students' results, independent of the used device. The students remarked a good handling of the ultrasound devices and supported the use in their future specialties.</p><p><strong>Discussion: </strong>The reliability between the examinations using the SUD and PUD were high but lower than the results observed for trained physicians. Therefore, the implementation of an additional module for portable ultrasound teaches the students to reliably examine basic obstetric parameters and provides a solid basis for further training and improvement of ultrasound skills in use of PUD.</p>","PeriodicalId":51234,"journal":{"name":"BMC Medical Education","volume":"25 1","pages":"103"},"PeriodicalIF":2.7000,"publicationDate":"2025-01-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11752848/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Education","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12909-025-06683-0","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"EDUCATION & EDUCATIONAL RESEARCH","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The technical development of ultrasound devices based on silicon chips has revolutionized ultrasound examinations, leading to the implementation of these portable handheld devices (PUD) in different medical fields. However, training on these devices is necessary to assure appropriate use and ensure valid results. While training programs for the use of conventional standard ultrasound devices (SUD) have been described, no training program for these handheld devices has been developed thus far.

Methods: A training program for obstetric ultrasound examination was modified through the addition of an extra module focusing on the use of these PUDs. After the module the students had to attend an OSCE in which their skills of using the PUD and the SUD were tested and analyzed by applying the agreement rate, the intraclass correlation coefficient (ICC) and Bland-Altman plots. Furthermore, the students' ultrasound results were compared with those of trained physicians by employing the one-sample Student's t-test. After the OSCE, the students answered a survey regarding their experience and their expected use of these devices.

Result: An agreement of one hundred percent was reached for basic parameters such as fetal position, placental position, fetal heartbeat and for the classification of the amniotic fluid. The ICC showed a good to moderate agreement between the results of fetal biometry achieved by SUD and PUD. The T-test results confirmed a high reliability between the physicians' results and the students' results, independent of the used device. The students remarked a good handling of the ultrasound devices and supported the use in their future specialties.

Discussion: The reliability between the examinations using the SUD and PUD were high but lower than the results observed for trained physicians. Therefore, the implementation of an additional module for portable ultrasound teaches the students to reliably examine basic obstetric parameters and provides a solid basis for further training and improvement of ultrasound skills in use of PUD.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Medical Education
BMC Medical Education EDUCATION, SCIENTIFIC DISCIPLINES-
CiteScore
4.90
自引率
11.10%
发文量
795
审稿时长
6 months
期刊介绍: BMC Medical Education is an open access journal publishing original peer-reviewed research articles in relation to the training of healthcare professionals, including undergraduate, postgraduate, and continuing education. The journal has a special focus on curriculum development, evaluations of performance, assessment of training needs and evidence-based medicine.
期刊最新文献
Effectiveness of deliberate practices versus conventional lecture in trauma training for medical students. Outcome-based simulation training for ultrasound-guided central venous catheter placement: clinical impact on preventing mechanical complications. Assessing the role of medical entomology in general medicine education in Iran: expert perspectives and curriculum implications. Brain drain in Emergency Medicine in Lebanon, building locally and exporting globally. Development and validation of a tool to measure telehealth educational environment (THEEM).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1