[Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures].

Guang-Yao Li, Yong-Zhong Cheng, Huan Liu, Jun-Jie Jiang, Yong-Yao Li, Yang Chen, Yu-Xiang Yao
{"title":"[Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures].","authors":"Guang-Yao Li, Yong-Zhong Cheng, Huan Liu, Jun-Jie Jiang, Yong-Yao Li, Yang Chen, Yu-Xiang Yao","doi":"10.12200/j.issn.1003-0034.20240557","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.</p><p><strong>Methods: </strong>PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.</p><p><strong>Results: </strong>(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss <i>MD</i>=-37.93, 95%<i>CI</i>(-48.54, -27.31), <i>P</i><0.000 01;operation time <i>MD</i>=-31.58, 95%<i>CI</i>(-48.96, -14.20), <i>P</i><0.000 4;hospitalization time <i>MD</i>=-4.58, 95%<i>CI</i>(-5.44, -3.71), <i>P</i><0.000 01;the fracture healing time <i>MD</i>=-0.88, 95%<i>CI</i>(-1.35, -0.41), <i>P</i><0.000 2, which were significantly better than that of the plate internal fixation group(<i>P</i><0.05).(3) The two groups:palmar inclination angle <i>MD</i>=-0.17, 95%<i>CI</i>(-0.95, 0.61), <i>P</i>=0.68;ulnar declination <i>MD</i>=0.22, 95%<i>CI</i>(-0.73, 1.17), <i>P</i>=0.65, radial height <i>MD</i>=-0.24, 95%<i>CI</i>(-1.15, 0.67), <i>P</i>=0.60;flexion and extension <i>MD</i>=-5.63, 95%<i>CI</i>(-11.85, 0.58), <i>P</i>=0.08;rotation <i>MD</i>=-5.80, 95%<i>CI</i>(-12.77, 1.17), <i>P</i>=0.10, radioulnar deviation <i>MD</i>=-2.86, 95%<i>CI</i>(-10.87, 5.15), <i>P</i>=0.48;complication rate <i>RR</i>=0.96, 95%<i>CI</i>(0.63, 1.46), <i>P</i>=0.83;Gartland-Werley clinical wrist score <i>MD</i>=0.13, 95%<i>CI</i>(-0.80, 1.06), <i>P</i>=0.78;excellent and good rate of Gartland-Werley wrist clinical score <i>RR</i>=0.93, 95%<i>CI</i>(0.87, 1.01), <i>P</i>=0.08;excellent and good rate of Cooney wrist score <i>RR</i>=0.99, 95%<i>CI</i>(0.62, 1.59), <i>P</i>=0.98;wrist DASH score <i>MD</i>=-4.67, 95%<i>CI</i>(-14.96, 5.62), <i>P</i>=0.37;the differences were not significant (<i>P</i>>0.05).</p><p><strong>Conclusion: </strong>Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.</p>","PeriodicalId":23964,"journal":{"name":"Zhongguo gu shang = China journal of orthopaedics and traumatology","volume":"38 1","pages":"66-80"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhongguo gu shang = China journal of orthopaedics and traumatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12200/j.issn.1003-0034.20240557","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.

Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.

Results: (1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).

Conclusion: Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
189
期刊最新文献
[Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures]. [Guiding significance of intra-articular sagittal reduction in the treatment of tibial plateau fractures]. [Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures]. [Preoperative diagnostic efficacy of novel blood markers white blood cell ratio and fibrinogen levels in periprosthetic joint infection]. [Short-term clinical efficacy of unilateral external fixator combined with percutaneous Kirschner wire fixation in the treatment of type C1 distal radius fractures in elderly patients].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1