Functional Improvements by Controlled Suture Tension in Arthroscopic Rotator Cuff Repair.

IF 2.3 Q2 ORTHOPEDICS JBJS Open Access Pub Date : 2025-01-23 eCollection Date: 2025-01-01 DOI:10.2106/JBJS.OA.24.00031
Shinji Imai
{"title":"Functional Improvements by Controlled Suture Tension in Arthroscopic Rotator Cuff Repair.","authors":"Shinji Imai","doi":"10.2106/JBJS.OA.24.00031","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Although a certain degree of tension in bridging sutures is required for proper tendon healing following suture-bridge rotator cuff repair, excessive suture tension may be detrimental to tendon healing. This study aimed to investigate the effects of bridging suture tension on clinical outcomes and tendon healing. We hypothesized that fixed, low tension of the bridging sutures would improve the tendon healing rate and clinical outcomes compared with maximum manual tensioning.</p><p><strong>Methods: </strong>A group of 39 patients with a rotator cuff tear were treated with arthroscopic suture-bridge rotator cuff repair, in which the bridging sutures were uniformly tensioned to 20 N (group A). A separate group of 37 patients was treated with the same suture construct, but the sutures were tensioned by maximum manual pulling (mean tension, 36.1 N; group B). The visual analog scale (VAS) score for pain, active anterior elevation, external and internal rotation, and Constant score were compared between the groups preoperatively and at 1, 3, and 6 months and 1 and 2 years postoperatively. Anatomical healing was evaluated using magnetic resonance imaging (MRI) at 1 year after surgery.</p><p><strong>Results: </strong>At 6 months postoperatively, all clinical values had improved in both groups. The Constant score (p < 0.001), VAS pain score (p < 0.001), and anterior elevation (p = 0.004) were significantly better in group A than in group B. Two years postoperatively, there was no significant difference between groups A and B in the Constant score (p = 0.847), VAS pain score (p = 0.991), and anterior elevation (p = 0.855). Group A demonstrated a significantly lower retear rate (3 of 39, 7.7%) than group B (9 of 37, 24.3%) (p = 0.0467).</p><p><strong>Conclusions: </strong>Double-row suture-bridge repairs with fixed, low tension led to superior clinical outcomes at 6 months and a superior tendon healing rate at 1 year compared with repairs with higher suture tension. However, the clinical outcomes did not differ significantly at 2 years between the 2 tensioning methods.</p><p><strong>Level of evidence: </strong>Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.</p>","PeriodicalId":36492,"journal":{"name":"JBJS Open Access","volume":"10 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-01-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11749655/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBJS Open Access","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2106/JBJS.OA.24.00031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Although a certain degree of tension in bridging sutures is required for proper tendon healing following suture-bridge rotator cuff repair, excessive suture tension may be detrimental to tendon healing. This study aimed to investigate the effects of bridging suture tension on clinical outcomes and tendon healing. We hypothesized that fixed, low tension of the bridging sutures would improve the tendon healing rate and clinical outcomes compared with maximum manual tensioning.

Methods: A group of 39 patients with a rotator cuff tear were treated with arthroscopic suture-bridge rotator cuff repair, in which the bridging sutures were uniformly tensioned to 20 N (group A). A separate group of 37 patients was treated with the same suture construct, but the sutures were tensioned by maximum manual pulling (mean tension, 36.1 N; group B). The visual analog scale (VAS) score for pain, active anterior elevation, external and internal rotation, and Constant score were compared between the groups preoperatively and at 1, 3, and 6 months and 1 and 2 years postoperatively. Anatomical healing was evaluated using magnetic resonance imaging (MRI) at 1 year after surgery.

Results: At 6 months postoperatively, all clinical values had improved in both groups. The Constant score (p < 0.001), VAS pain score (p < 0.001), and anterior elevation (p = 0.004) were significantly better in group A than in group B. Two years postoperatively, there was no significant difference between groups A and B in the Constant score (p = 0.847), VAS pain score (p = 0.991), and anterior elevation (p = 0.855). Group A demonstrated a significantly lower retear rate (3 of 39, 7.7%) than group B (9 of 37, 24.3%) (p = 0.0467).

Conclusions: Double-row suture-bridge repairs with fixed, low tension led to superior clinical outcomes at 6 months and a superior tendon healing rate at 1 year compared with repairs with higher suture tension. However, the clinical outcomes did not differ significantly at 2 years between the 2 tensioning methods.

Level of evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
JBJS Open Access
JBJS Open Access Medicine-Surgery
CiteScore
5.00
自引率
0.00%
发文量
77
审稿时长
6 weeks
期刊最新文献
Robot-Assisted Retrograde Elastic Intramedullary Nailing Versus ORIF with a Plate for Displaced Midshaft Clavicular Fractures. Functional Improvements by Controlled Suture Tension in Arthroscopic Rotator Cuff Repair. An Updated Demographic Profile of Orthopaedic Surgery Using a New ABOS Data Set. ASA Class Is a Stronger Predictor of Early Revision Risk Following Primary Total Knee Arthroplasty than BMI. Erratum: Expanding the Pipeline: Exposure and Female Mentorship Increase Interest in Orthopaedic Surgery Among Female Premedical Undergraduate Students: Erratum.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1