Comparison of Mirroring and Overlapping Analysis and Three-Dimensional Soft Tissue Spatial Angle Wireframe Template in Evaluating Facial Asymmetry.

IF 3.7 3区 医学 Q2 ENGINEERING, BIOMEDICAL Bioengineering Pub Date : 2025-01-16 DOI:10.3390/bioengineering12010079
Gengchen Yang, Liang Lyu, Aonan Wen, Yijiao Zhao, Yong Wang, Jing Li, Huichun Yan, Mingjin Zhang, Yi Yu, Tingting Yu, Dawei Liu
{"title":"Comparison of Mirroring and Overlapping Analysis and Three-Dimensional Soft Tissue Spatial Angle Wireframe Template in Evaluating Facial Asymmetry.","authors":"Gengchen Yang, Liang Lyu, Aonan Wen, Yijiao Zhao, Yong Wang, Jing Li, Huichun Yan, Mingjin Zhang, Yi Yu, Tingting Yu, Dawei Liu","doi":"10.3390/bioengineering12010079","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The purpose of this study was to evaluate the accuracy and efficacy of a new wireframe template methodology in analyzing three-dimensional facial soft tissue asymmetry.</p><p><strong>Materials and methods: </strong>Three-dimensional facial soft tissue data were obtained for 24 patients. The wireframe template was established by identifying 34 facial landmarks and then forming a template on the face with the MeshLab 2020 software. The angle asymmetry index was automatically scored using the template. The mirroring and overlapping technique is accepted as the golden standard method to diagnose facial asymmetry by acquiring deviation values of one's face. Consistency rates between the two methodologies were determined through a statistical comparison of the angle asymmetry index and deviation values.</p><p><strong>Results: </strong>Overall consistency rates in the labial, mandibular angle, cheek, chin, and articular regions were 87.5%, 95.8%, 87.5%, 91.7%, and 100%, respectively. Regions with consistency rates in three dimensions of more than 85% are the <i>x</i>-axis and the <i>z</i>-axis of all regions and the <i>y</i>-axis of the mandibular angle, chin, and articular region.</p><p><strong>Conclusions: </strong>Soft tissue facial asymmetry can be diagnosed accurately and effectively by using a three-dimensional soft tissue spatial angle wireframe template. Precise localization of asymmetry can be offered, and indiscernible tiny asymmetry can be identified.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"12 1","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11761234/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering12010079","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The purpose of this study was to evaluate the accuracy and efficacy of a new wireframe template methodology in analyzing three-dimensional facial soft tissue asymmetry.

Materials and methods: Three-dimensional facial soft tissue data were obtained for 24 patients. The wireframe template was established by identifying 34 facial landmarks and then forming a template on the face with the MeshLab 2020 software. The angle asymmetry index was automatically scored using the template. The mirroring and overlapping technique is accepted as the golden standard method to diagnose facial asymmetry by acquiring deviation values of one's face. Consistency rates between the two methodologies were determined through a statistical comparison of the angle asymmetry index and deviation values.

Results: Overall consistency rates in the labial, mandibular angle, cheek, chin, and articular regions were 87.5%, 95.8%, 87.5%, 91.7%, and 100%, respectively. Regions with consistency rates in three dimensions of more than 85% are the x-axis and the z-axis of all regions and the y-axis of the mandibular angle, chin, and articular region.

Conclusions: Soft tissue facial asymmetry can be diagnosed accurately and effectively by using a three-dimensional soft tissue spatial angle wireframe template. Precise localization of asymmetry can be offered, and indiscernible tiny asymmetry can be identified.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
镜像重叠分析与三维软组织空间角度线框模板评价面部不对称的比较。
目的:本研究的目的是评估一种新的线框模板方法分析三维面部软组织不对称的准确性和有效性。材料与方法:获取24例患者面部三维软组织数据。通过识别34个面部地标,利用MeshLab 2020软件在人脸上形成线框模板,建立线框模板。采用该模板对角度不对称指数进行自动评分。镜像叠加技术是通过获取面部偏差值来诊断面部不对称的金标准方法。通过角度不对称指数和偏差值的统计比较,确定了两种方法之间的一致性率。结果:唇区、下颌角区、颊区、颏区、关节区的总体一致性分别为87.5%、95.8%、87.5%、91.7%、100%。三个维度一致性大于85%的区域为所有区域的x轴和z轴以及下颌角、下巴和关节区域的y轴。结论:应用三维软组织空间角度线框模板可以准确、有效地诊断软组织面部不对称。可以提供不对称的精确定位,并且可以识别难以识别的微小不对称。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Bioengineering
Bioengineering Chemical Engineering-Bioengineering
CiteScore
4.00
自引率
8.70%
发文量
661
期刊介绍: Aims Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal: ● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings. ● Manuscripts regarding research proposals and research ideas will be particularly welcomed. ● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material. ● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds. Scope ● Bionics and biological cybernetics: implantology; bio–abio interfaces ● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices ● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc. ● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology ● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering ● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation ● Translational bioengineering
期刊最新文献
Advances in Decellularization of Fish Wastes for Extracellular Matrix Extraction in Sustainable Tissue Engineering and Regenerative Medicine. Limb-Salvage Reconstruction of the Proximal Humerus Using Patient-Specific 3D-Printed PEEK Implants: A Midterm Clinical Study. First Report of Pichia bruneiensis in a Spontaneous Sugarcane Juice Fermentation: A Case Study from an Artisanal Distillery in the Ecuadorian Amazon. Development and Evaluation of a Urinary Na/K Ratio Prediction Model: A Systematic Comparison from Attention-Based Deep Learning to Classical Ensemble Approaches. Clinical Validation of rPPG-Enabled Contactless Pulse Rate Monitoring Software in Cardiovascular Disease Patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1