{"title":"Effects of Different Voided Urine Sample Storage Time, Temperature, and Preservatives on Analysis with Multiplex Bead-Based Oncuria Bladder Cancer Immunoassay.","authors":"Sunao Tanaka, Kaoru Murakami, Toru Sakatani, Riko Lee, Wayne Hogrefe, Fernando Siguencia, Charles J Rosser, Hideki Furuya","doi":"10.3390/diagnostics15020138","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives:</b> Urinalysis accuracy requires reliable sample stability that is dependent on the chosen collection and storage conditions. The multiplex Oncuria bladder cancer immunoassay currently needs urine samples stored at 4 °C until analysis, which requires more effort, equipment, and workflow than storing samples at room temperature. Thus, successful sample storage at room temperature (20 °C) may reduce laboratory handling time and expenses. This study evaluated whether different voided urine sample collection and storage parameters affected subsequent biomarker analysis with Oncuria. The Oncuria simultaneously quantifies 10 protein analytes in urine to generate a bladder cancer diagnostic signature. <b>Methods</b>: Samples were stored at varied temperatures (20 °C, 4 °C, -20 °C) for up to 1 month. The effects of adding two commercial urine sample stabilizers and antibiotics (trimethoprim) were also assessed. Subsequently, multiple potential biospecimen stabilizers were tested in urine samples and evaluated with Oncuria in hopes of allowing the urine sample to remain at room temperature for extended periods of time. <b>Results</b>: First, it was demonstrated that voided urine samples stored at room temperate without such stabilizers had different levels of the 10 analytes associated with the Oncuria test compared to voided urine samples stored at 4 °C. Next, we evaluated the effects of commercially available biospecimen stabilizers. Despite the addition of these stabilizers, the levels of the 10 analytes were altered when the samples were stored at room temperature for prolonged periods of time. Therefore, we could not identify a suitable biospecimen stabilizer that would not require sample refrigeration. <b>Conclusions</b>: To minimize sample degradation/alteration after collection, voided urine samples should be refrigerated until analyzed with Oncuria as the refrigeration is advantageous for the storage and the transport of these urine samples.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"15 2","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11763964/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics15020138","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objectives: Urinalysis accuracy requires reliable sample stability that is dependent on the chosen collection and storage conditions. The multiplex Oncuria bladder cancer immunoassay currently needs urine samples stored at 4 °C until analysis, which requires more effort, equipment, and workflow than storing samples at room temperature. Thus, successful sample storage at room temperature (20 °C) may reduce laboratory handling time and expenses. This study evaluated whether different voided urine sample collection and storage parameters affected subsequent biomarker analysis with Oncuria. The Oncuria simultaneously quantifies 10 protein analytes in urine to generate a bladder cancer diagnostic signature. Methods: Samples were stored at varied temperatures (20 °C, 4 °C, -20 °C) for up to 1 month. The effects of adding two commercial urine sample stabilizers and antibiotics (trimethoprim) were also assessed. Subsequently, multiple potential biospecimen stabilizers were tested in urine samples and evaluated with Oncuria in hopes of allowing the urine sample to remain at room temperature for extended periods of time. Results: First, it was demonstrated that voided urine samples stored at room temperate without such stabilizers had different levels of the 10 analytes associated with the Oncuria test compared to voided urine samples stored at 4 °C. Next, we evaluated the effects of commercially available biospecimen stabilizers. Despite the addition of these stabilizers, the levels of the 10 analytes were altered when the samples were stored at room temperature for prolonged periods of time. Therefore, we could not identify a suitable biospecimen stabilizer that would not require sample refrigeration. Conclusions: To minimize sample degradation/alteration after collection, voided urine samples should be refrigerated until analyzed with Oncuria as the refrigeration is advantageous for the storage and the transport of these urine samples.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Diagnostics
Diagnostics Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍: Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.
期刊最新文献
Machine-Learning Parsimonious Prediction Model for Diagnostic Screening of Severe Hematological Adverse Events in Cancer Patients Treated with PD-1/PD-L1 Inhibitors: Retrospective Observational Study by Using the Common Data Model. Unlocking the Potential of RNA Sequencing in COVID-19: Toward Accurate Diagnosis and Personalized Medicine. Evaluation of Retinal Changes in Women with Different Phenotypes of Polycystic Ovary Syndrome. Maternal Uterine Artery Doppler and Serum Marker in the First Trimester as Predictive Markers for Small for Gestational Age Neonates and Preeclampsia: A Pilot Study. Controversies in the Application of AI in Radiology-Is There Medico-Legal Support? Aspects from Romanian Practice.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1