The 9/3 Min Running Test: A Simple and Practical Approach to Estimate the Critical and Maximal Aerobic Power

Santiago A. Ruiz-Alias, Aitor Marcos-Blanco, Iván Fernández-Navarrete, Alejandro Pérez-Castilla, Felipe García-Pinillos
{"title":"The 9/3 Min Running Test: A Simple and Practical Approach to Estimate the Critical and Maximal Aerobic Power","authors":"Santiago A. Ruiz-Alias,&nbsp;Aitor Marcos-Blanco,&nbsp;Iván Fernández-Navarrete,&nbsp;Alejandro Pérez-Castilla,&nbsp;Felipe García-Pinillos","doi":"10.1002/ejsc.12254","DOIUrl":null,"url":null,"abstract":"<p>This study aims to determine the validity of the linear critical power (CP) and Peronnet models to estimate the power output associated with the second ventilatory threshold (VT2) and the maximal aerobic power (MAP) using two-time trials. Nineteen recreational runners (10 males and 9 females and maximum oxygen uptake: 53.0 ± 4.7 mL/kg/min) performed a graded exercise test (GXT) to determine the VT2 and MAP. On a second test, athletes performed two-time trials of 9 and 3 min interspaced by 30 min. The CP was determined from the linear CP model and compared with the power output associated with the VT2. The MAP was determined from the linear Peronnet model, established at 7 min, and compared with the MAP determined in the GXT. The CP model was valid for determining the VT2, regardless of sex (<i>p</i> = 0.130; 9/3 vs. GXT: 3.5 [−1.1 to 8.2] W). The MAP was overestimated (<i>p</i> = 0.015) specifically in males (9/3 vs. GXT: 9.2 [3.3 to 15.1] W) rather than in females (<i>p</i> = 9/3 vs. GXT: 1.7 [−4.4 to 8.0] W). Therefore, MAP estimates were determined introducing the CP and W' parameters to a stepwise multiple linear regression analysis. For females, the CP was the unique significant predictor of MAP (<i>p</i> &lt; 0.001) explaining 96.7% of the variance. In males, both CP and W' were significant predictors of MAP (<i>p</i> &lt; 0.001) explaining 97.7% of the variance. Practitioners can validly estimate the VT2 and MAP through a practical testing protocol in both male and female recreational runners.</p>","PeriodicalId":93999,"journal":{"name":"European journal of sport science","volume":"25 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11770271/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of sport science","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ejsc.12254","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aims to determine the validity of the linear critical power (CP) and Peronnet models to estimate the power output associated with the second ventilatory threshold (VT2) and the maximal aerobic power (MAP) using two-time trials. Nineteen recreational runners (10 males and 9 females and maximum oxygen uptake: 53.0 ± 4.7 mL/kg/min) performed a graded exercise test (GXT) to determine the VT2 and MAP. On a second test, athletes performed two-time trials of 9 and 3 min interspaced by 30 min. The CP was determined from the linear CP model and compared with the power output associated with the VT2. The MAP was determined from the linear Peronnet model, established at 7 min, and compared with the MAP determined in the GXT. The CP model was valid for determining the VT2, regardless of sex (p = 0.130; 9/3 vs. GXT: 3.5 [−1.1 to 8.2] W). The MAP was overestimated (p = 0.015) specifically in males (9/3 vs. GXT: 9.2 [3.3 to 15.1] W) rather than in females (p = 9/3 vs. GXT: 1.7 [−4.4 to 8.0] W). Therefore, MAP estimates were determined introducing the CP and W' parameters to a stepwise multiple linear regression analysis. For females, the CP was the unique significant predictor of MAP (p < 0.001) explaining 96.7% of the variance. In males, both CP and W' were significant predictors of MAP (p < 0.001) explaining 97.7% of the variance. Practitioners can validly estimate the VT2 and MAP through a practical testing protocol in both male and female recreational runners.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
9/3 分钟跑步测试:估算临界和最大有氧功率的简单实用方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Issue Information Assessment of Biological Age With Conventional Ultrasound Imaging as an Alternative to X-Ray—A Pilot Study in Youth Soccer No Effect of Acute or Chronic New Zealand Blackcurrant Extract on Cycling Performance or Physiological Responses in Trained Cyclists Pre-Season Energy Deficiency Predicts Poorer Performance During a Competitive Season in Collegiate Female Long-Distance Runners The Order of Concurrent Training Affects Acute Immunological Stress Responses and Measures of Muscular Fitness in Female Youth Judo Athletes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1