Yunpeng Wang, Gaohui Zhu, Danhua Li, Yu Pan, Rong Li, Ting Zhou, Aiping Mao, Libao Chen, Jing Zhu, Min Zhu
{"title":"High clinical utility of long-read sequencing for precise diagnosis of congenital adrenal hyperplasia in 322 probands.","authors":"Yunpeng Wang, Gaohui Zhu, Danhua Li, Yu Pan, Rong Li, Ting Zhou, Aiping Mao, Libao Chen, Jing Zhu, Min Zhu","doi":"10.1186/s40246-024-00696-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The molecular genetic diagnosis of congenital adrenal hyperplasia (CAH) is very challenging due to the high homology between the CYP21A2 gene and its pseudogene CYP21A1P.</p><p><strong>Methodology: </strong>This study aims to assess the clinical efficacy of targeted long-read sequencing (T-LRS) by comparing it with a control method based on the combined assay (NGS, Multiplex ligation-dependent probe amplification and Sanger sequencing) and to introduce T-LRS as a first-tier diagnostic test for suspected CAH patients to improve the precise diagnosis of CAH.</p><p><strong>Results: </strong>A large cohort of 562 participants including 322 probands and 240 family members was enrolled for the perspective (96 probands) and prospective study (226 probands). The comparison analysis of T-LRS and control method have been performed. In the perspective study, 96 probands were identified using both the control method and T-LRS. Concordant results were detected in 85.42% (82/96) of probands. T-LRS performed more precise diagnosis in 14.58% (14/96) of probands. Among these, a novel 4141 kb deletion involving CYP21A2 and TNXB was established. A new diagnosis was improved by T-LRS. The duplications were also precisely identified to clarify the misdiagnosis by MLPA. In the prospective study, Variants were identified not only in CYP21A2 but also in HSD3B2 and CYP11B1 in 226 probands. Expand to 322 probands, the actual frequency of duplication haplotype (1.55%) could be calculated due to the accurate genotyping. Moreover, 75.47% of alleles with SNVs/indels, 22.20% of alleles with deletion chimeras.</p><p><strong>Conclusion: </strong>T-LRS has higher resolution and reduced cost than control method with accurate diagnosis. The clinical utility of L-LRS could help to provide precision therapy to CAH patients, advance the life-long management of this complex disease and promote our understanding of CAH.</p>","PeriodicalId":13183,"journal":{"name":"Human Genomics","volume":"19 1","pages":"3"},"PeriodicalIF":3.8000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11731552/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Human Genomics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40246-024-00696-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GENETICS & HEREDITY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The molecular genetic diagnosis of congenital adrenal hyperplasia (CAH) is very challenging due to the high homology between the CYP21A2 gene and its pseudogene CYP21A1P.
Methodology: This study aims to assess the clinical efficacy of targeted long-read sequencing (T-LRS) by comparing it with a control method based on the combined assay (NGS, Multiplex ligation-dependent probe amplification and Sanger sequencing) and to introduce T-LRS as a first-tier diagnostic test for suspected CAH patients to improve the precise diagnosis of CAH.
Results: A large cohort of 562 participants including 322 probands and 240 family members was enrolled for the perspective (96 probands) and prospective study (226 probands). The comparison analysis of T-LRS and control method have been performed. In the perspective study, 96 probands were identified using both the control method and T-LRS. Concordant results were detected in 85.42% (82/96) of probands. T-LRS performed more precise diagnosis in 14.58% (14/96) of probands. Among these, a novel 4141 kb deletion involving CYP21A2 and TNXB was established. A new diagnosis was improved by T-LRS. The duplications were also precisely identified to clarify the misdiagnosis by MLPA. In the prospective study, Variants were identified not only in CYP21A2 but also in HSD3B2 and CYP11B1 in 226 probands. Expand to 322 probands, the actual frequency of duplication haplotype (1.55%) could be calculated due to the accurate genotyping. Moreover, 75.47% of alleles with SNVs/indels, 22.20% of alleles with deletion chimeras.
Conclusion: T-LRS has higher resolution and reduced cost than control method with accurate diagnosis. The clinical utility of L-LRS could help to provide precision therapy to CAH patients, advance the life-long management of this complex disease and promote our understanding of CAH.
期刊介绍:
Human Genomics is a peer-reviewed, open access, online journal that focuses on the application of genomic analysis in all aspects of human health and disease, as well as genomic analysis of drug efficacy and safety, and comparative genomics.
Topics covered by the journal include, but are not limited to: pharmacogenomics, genome-wide association studies, genome-wide sequencing, exome sequencing, next-generation deep-sequencing, functional genomics, epigenomics, translational genomics, expression profiling, proteomics, bioinformatics, animal models, statistical genetics, genetic epidemiology, human population genetics and comparative genomics.