Reduction of Streak Artifacts in the Superior Vena Cava for Better Visualization of Mediastinal Structures Through Virtual Monoenergetic Reconstructions Using a Photon-counting Detector Computed Tomography.

IF 2 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Thoracic Imaging Pub Date : 2025-01-31 DOI:10.1097/RTI.0000000000000822
Greta Thater, Isabel Frerichs, Sylvia Büttner, Stefan O Schoenberg, Matthias Froelich, Isabelle Ayx
{"title":"Reduction of Streak Artifacts in the Superior Vena Cava for Better Visualization of Mediastinal Structures Through Virtual Monoenergetic Reconstructions Using a Photon-counting Detector Computed Tomography.","authors":"Greta Thater, Isabel Frerichs, Sylvia Büttner, Stefan O Schoenberg, Matthias Froelich, Isabelle Ayx","doi":"10.1097/RTI.0000000000000822","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Computed tomography (CT) is crucial in oncologic imaging for precise diagnosis and staging. Beam-hardening artifacts from contrast media in the superior vena cava can degrade image quality and obscure adjacent structures, complicating lymph node assessment. This study examines the use of virtual monoenergetic reconstruction with photon-counting detector CT (photon-counting CT) to mitigate these artifacts.</p><p><strong>Materials and methods: </strong>The retrospective study included 50 patients who underwent thoracoabdominal scans. Virtual monoenergetic reconstructions at nine keV levels (60 to 140 keV) were analyzed for Hounsfield Unit (HU) stability, image noise, and artifact index in various regions of interest (ROIs): mediastinal adipose tissue (ROI 1 to 3) and vascular stations (ROI 4 to 6) were compared with reference tissue (ROI 7 to 8). The diagnostic image quality of the keV levels was assessed using a 5-point Likert Scale.</p><p><strong>Results: </strong>Lower keV values (60 to 80) exhibited higher image noise and lower HU stability in mediastinal adipose tissue compared with higher energies, with optimal noise reduction observed at 130 keV (ROI 1 to 3). HU stability in vascular structures (ROI 4 to 6) significantly improved above 80 keV, with the best performance at 140 keV. Artifact levels decreased progressively from 60 to 140 keV. Visually, keV levels of 110 keV (96% Likert ≥4) and 120 keV (60% Likert 4) were rated most diagnostically valuable, consistent with technical findings.</p><p><strong>Conclusion: </strong>Virtual monoenergetic reconstructions with photon-counting CT effectively reduce beam-hardening artifacts near the superior vena cava, enhancing the visualization of lymph nodes and adjacent structures. This technology advances oncologic imaging by improving diagnostic accuracy in areas previously affected by artifact-related image degradation.</p>","PeriodicalId":49974,"journal":{"name":"Journal of Thoracic Imaging","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thoracic Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RTI.0000000000000822","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Computed tomography (CT) is crucial in oncologic imaging for precise diagnosis and staging. Beam-hardening artifacts from contrast media in the superior vena cava can degrade image quality and obscure adjacent structures, complicating lymph node assessment. This study examines the use of virtual monoenergetic reconstruction with photon-counting detector CT (photon-counting CT) to mitigate these artifacts.

Materials and methods: The retrospective study included 50 patients who underwent thoracoabdominal scans. Virtual monoenergetic reconstructions at nine keV levels (60 to 140 keV) were analyzed for Hounsfield Unit (HU) stability, image noise, and artifact index in various regions of interest (ROIs): mediastinal adipose tissue (ROI 1 to 3) and vascular stations (ROI 4 to 6) were compared with reference tissue (ROI 7 to 8). The diagnostic image quality of the keV levels was assessed using a 5-point Likert Scale.

Results: Lower keV values (60 to 80) exhibited higher image noise and lower HU stability in mediastinal adipose tissue compared with higher energies, with optimal noise reduction observed at 130 keV (ROI 1 to 3). HU stability in vascular structures (ROI 4 to 6) significantly improved above 80 keV, with the best performance at 140 keV. Artifact levels decreased progressively from 60 to 140 keV. Visually, keV levels of 110 keV (96% Likert ≥4) and 120 keV (60% Likert 4) were rated most diagnostically valuable, consistent with technical findings.

Conclusion: Virtual monoenergetic reconstructions with photon-counting CT effectively reduce beam-hardening artifacts near the superior vena cava, enhancing the visualization of lymph nodes and adjacent structures. This technology advances oncologic imaging by improving diagnostic accuracy in areas previously affected by artifact-related image degradation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Thoracic Imaging
Journal of Thoracic Imaging 医学-核医学
CiteScore
7.10
自引率
9.10%
发文量
87
审稿时长
6-12 weeks
期刊介绍: Journal of Thoracic Imaging (JTI) provides authoritative information on all aspects of the use of imaging techniques in the diagnosis of cardiac and pulmonary diseases. Original articles and analytical reviews published in this timely journal provide the very latest thinking of leading experts concerning the use of chest radiography, computed tomography, magnetic resonance imaging, positron emission tomography, ultrasound, and all other promising imaging techniques in cardiopulmonary radiology. Official Journal of the Society of Thoracic Radiology: Japanese Society of Thoracic Radiology Korean Society of Thoracic Radiology European Society of Thoracic Imaging.
期刊最新文献
Accuracy of Single-dose Transcatheter Aortic Valve Replacement Planning CT Angiography for the Detection of Coronary Artery Disease. Reduction of Streak Artifacts in the Superior Vena Cava for Better Visualization of Mediastinal Structures Through Virtual Monoenergetic Reconstructions Using a Photon-counting Detector Computed Tomography. Pulmonary Aspiration Syndromes: An Imaging-based Review. Clinical Validation of a Deep Learning Algorithm for Automated Coronary Artery Disease Detection and Classification Using a Heterogeneous Multivendor Coronary Computed Tomography Angiography Data Set. Clinical and Imaging Features of Pulmonary Nodular Lymphoid Hyperplasia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1