Flex vs. Vantage Pipeline™ Flow Diverters: Technical analysis in treating complex fusiform basilar artery aneurysm.

IF 1.7 4区 医学 Q3 Medicine Interventional Neuroradiology Pub Date : 2025-01-07 DOI:10.1177/15910199241311074
Harsh Desai, Sonam Thind, Rami Z Morsi, Sachin A Kothari, Lina Karar, Ahmad Chahine, Jehad Zakaria, Tareq Kass-Hout
{"title":"Flex vs. Vantage Pipeline™ Flow Diverters: Technical analysis in treating complex fusiform basilar artery aneurysm.","authors":"Harsh Desai, Sonam Thind, Rami Z Morsi, Sachin A Kothari, Lina Karar, Ahmad Chahine, Jehad Zakaria, Tareq Kass-Hout","doi":"10.1177/15910199241311074","DOIUrl":null,"url":null,"abstract":"<p><p>We present a case of an adult patient with a large symptomatic fusiform basilar artery aneurysm. This video demonstrates the ease of deploying the new Pipeline™ Vantage Flow Diverter compared to the Flex model in the same vessel. The Flex and Vantage have different deployment techniques-as using the Flex maneuvering technique on the Vantage may damage the braid. The Vantage stent does not require resheathing, dragging, or system loading. The video shows the operator's hands making multiple adjustments to deploy the Flex, while they deploy two Vantage stents and a LOBO<sup>®</sup> device occluder before fully deploying the Flex. The Vantage appears to offer a simpler, more streamlined deployment process of mostly unsheathing compared to the Flex flow diverter. Also, the Vantage design might offer a higher aneurysmal occlusion rate with a shorter course of anti-platelet regimen.<sup>1</sup> Of note, the Pipeline™ Shield may be a more appropriate option in some cases.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199241311074"},"PeriodicalIF":1.7000,"publicationDate":"2025-01-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11780492/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241311074","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

We present a case of an adult patient with a large symptomatic fusiform basilar artery aneurysm. This video demonstrates the ease of deploying the new Pipeline™ Vantage Flow Diverter compared to the Flex model in the same vessel. The Flex and Vantage have different deployment techniques-as using the Flex maneuvering technique on the Vantage may damage the braid. The Vantage stent does not require resheathing, dragging, or system loading. The video shows the operator's hands making multiple adjustments to deploy the Flex, while they deploy two Vantage stents and a LOBO® device occluder before fully deploying the Flex. The Vantage appears to offer a simpler, more streamlined deployment process of mostly unsheathing compared to the Flex flow diverter. Also, the Vantage design might offer a higher aneurysmal occlusion rate with a shorter course of anti-platelet regimen.1 Of note, the Pipeline™ Shield may be a more appropriate option in some cases.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.80
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
期刊最新文献
Flex vs. Vantage Pipeline™ Flow Diverters: Technical analysis in treating complex fusiform basilar artery aneurysm. The relative cerebral blood volume (rCBV) < 42% is independently associated with hemorrhagic transformation in anterior circulation large vessel occlusion. Macrowire for intracranial thrombectomy: An early experience of a new device and technique for anterior circulation large vessel occlusion stroke. Middle meningeal artery embolization in migraine: From concept to reality. Macrowire for Intracranial Thrombectomy: A Video Description.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1