Influence of Multiband Technique on Temporal Diffusion Spectroscopy and Its Diagnostic Value in Breast Tumors.

IF 3.3 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Magnetic Resonance Imaging Pub Date : 2025-01-31 DOI:10.1002/jmri.29715
Jie Ding, Zhen Zhang, Hongyan Xiao, Lijia Zhi, Xiuzheng Yue, Dazhi Chen, Rongrong Zhu, Lili Yang, Chao You, Yajia Gu
{"title":"Influence of Multiband Technique on Temporal Diffusion Spectroscopy and Its Diagnostic Value in Breast Tumors.","authors":"Jie Ding, Zhen Zhang, Hongyan Xiao, Lijia Zhi, Xiuzheng Yue, Dazhi Chen, Rongrong Zhu, Lili Yang, Chao You, Yajia Gu","doi":"10.1002/jmri.29715","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Temporal diffusion spectroscopy (TDS) is a noninvasive diffusion imaging technique used to characterizing cellular microstructures. The influence of multiband (MB) on TDS, particularly in breast tumor imaging remain unknown.</p><p><strong>Purpose: </strong>To investigate the influence of MB on TDS in terms of scanning time, image quality, and quantitative parameters and to assess the diagnostic value of TDS with MB in breast tumors.</p><p><strong>Study type: </strong>Prospective.</p><p><strong>Population: </strong>Seventy-one women with 71 confirmed lesions.</p><p><strong>Field strength/sequence: </strong>3.0 T; oscillating gradient spin-echo (OGSE), OGSE with MB, and pulsed gradient spin-echo, and routine magnetic resonance imaging squences.</p><p><strong>Assessment: </strong>TDS with MB was used to assess diagnostic efficacy in differentiating benign and malignant tumors. A comparison of scanning time and image quality was performed in 17 patients. Imaging parameters were analyzed using limited spectrally edited diffusion (IMPULSED) and apparent diffusion coefficient (ADC) values were compared between MB and non-MB protocols. The cell diameter from TDS was compared with histopathological measurements in 21 patients.</p><p><strong>Statistical tests: </strong>Bland-Altman plot, paired t test, Mann-Whitney U test, kappa test, DeLong's test, intraclass correlation coefficient agreement, receiver operating characteristic curve, area under the curve (AUC), and simple linear regression, with statistical significance set at P < 0.05.</p><p><strong>Results: </strong>The TDS with MB protocol had a shorter average scanning time than that without MB protocol (7 minutes 22 seconds vs. 12 minutes 28 seconds); image quality was improved by reducing image artifacts. Most IMPULSED parameters and ADC values did not significantly differ between the MB and non-MB protocols (P = 0.23, P = 0.17). The IMPULSED parameters of cellularity and intracellular volume fraction achieved the highest AUC values for distinguishing breast tumors (0.865 and 0.821, respectively), surpassing the diagnostic efficiency of conventional ADC-1000 (0.776). The correlation between IMPULSED parameters and microscopic cell size was strong (r = 0.842).</p><p><strong>Data conclusion: </strong>The MB technique improved the TDS protocol's efficiency and reduced the image artifacts. TDS parameters correlated with pathological findings and showed good performance in differentiating benign from malignant breast tumors.</p><p><strong>Plain language summary: </strong>We explored the impact of simultaneous multislice acquisition technology on temporal diffusion spectroscopy (TDS) and whether combining this method could help distinguish benign from malignant breast tumors. Our findings showed that simultaneous multislice acquisition technology shortened the scanning time and improved image quality by reducing motion-related issues. Additionally, measurements of cell size using simultaneous multislice acquisition technology matched well with results from pathology tests. Overall, our study suggests that simultaneous multislice acquisition enhanced TDS could make breast cancer diagnosis more accurate and efficient, offering good advantages compared to conventional imaging methods.</p><p><strong>Level of evidence: </strong>2 TECHNICAL EFFICACY: Stage 2.</p>","PeriodicalId":16140,"journal":{"name":"Journal of Magnetic Resonance Imaging","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jmri.29715","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Temporal diffusion spectroscopy (TDS) is a noninvasive diffusion imaging technique used to characterizing cellular microstructures. The influence of multiband (MB) on TDS, particularly in breast tumor imaging remain unknown.

Purpose: To investigate the influence of MB on TDS in terms of scanning time, image quality, and quantitative parameters and to assess the diagnostic value of TDS with MB in breast tumors.

Study type: Prospective.

Population: Seventy-one women with 71 confirmed lesions.

Field strength/sequence: 3.0 T; oscillating gradient spin-echo (OGSE), OGSE with MB, and pulsed gradient spin-echo, and routine magnetic resonance imaging squences.

Assessment: TDS with MB was used to assess diagnostic efficacy in differentiating benign and malignant tumors. A comparison of scanning time and image quality was performed in 17 patients. Imaging parameters were analyzed using limited spectrally edited diffusion (IMPULSED) and apparent diffusion coefficient (ADC) values were compared between MB and non-MB protocols. The cell diameter from TDS was compared with histopathological measurements in 21 patients.

Statistical tests: Bland-Altman plot, paired t test, Mann-Whitney U test, kappa test, DeLong's test, intraclass correlation coefficient agreement, receiver operating characteristic curve, area under the curve (AUC), and simple linear regression, with statistical significance set at P < 0.05.

Results: The TDS with MB protocol had a shorter average scanning time than that without MB protocol (7 minutes 22 seconds vs. 12 minutes 28 seconds); image quality was improved by reducing image artifacts. Most IMPULSED parameters and ADC values did not significantly differ between the MB and non-MB protocols (P = 0.23, P = 0.17). The IMPULSED parameters of cellularity and intracellular volume fraction achieved the highest AUC values for distinguishing breast tumors (0.865 and 0.821, respectively), surpassing the diagnostic efficiency of conventional ADC-1000 (0.776). The correlation between IMPULSED parameters and microscopic cell size was strong (r = 0.842).

Data conclusion: The MB technique improved the TDS protocol's efficiency and reduced the image artifacts. TDS parameters correlated with pathological findings and showed good performance in differentiating benign from malignant breast tumors.

Plain language summary: We explored the impact of simultaneous multislice acquisition technology on temporal diffusion spectroscopy (TDS) and whether combining this method could help distinguish benign from malignant breast tumors. Our findings showed that simultaneous multislice acquisition technology shortened the scanning time and improved image quality by reducing motion-related issues. Additionally, measurements of cell size using simultaneous multislice acquisition technology matched well with results from pathology tests. Overall, our study suggests that simultaneous multislice acquisition enhanced TDS could make breast cancer diagnosis more accurate and efficient, offering good advantages compared to conventional imaging methods.

Level of evidence: 2 TECHNICAL EFFICACY: Stage 2.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
9.70
自引率
6.80%
发文量
494
审稿时长
2 months
期刊介绍: The Journal of Magnetic Resonance Imaging (JMRI) is an international journal devoted to the timely publication of basic and clinical research, educational and review articles, and other information related to the diagnostic applications of magnetic resonance.
期刊最新文献
Issue Information Deep Learning-Based Techniques in Glioma Brain Tumor Segmentation Using Multi-Parametric MRI: A Review on Clinical Applications and Future Outlooks MRI Assessment of Geometric Microstructural Changes of White Matter in Infants With Periventricular White Matter Injury and Spastic Cerebral Palsy. Diagnosis of Sacroiliitis Through Semi-Supervised Segmentation and Radiomics Feature Analysis of MRI Images. Editorial for "Associations of Central Arterial Stiffness With Brain White Matter Integrity and Gray Matter Volume in MRI Across the Adult Lifespan".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1