{"title":"In-vitro accuracy of the virtual patient model with maxillomandibular relationship at centric occlusion using 3D-printed customized transfer key.","authors":"Anh Ho-Quynh Nguyen, Nam Cong-Nhat Huynh, Oanh Ngoc-Hoang Nguyen, Nhat Dinh-Minh Nguyen, Hai Hoang Phan, Jong-Eun Kim, Gan Jin, Khanh Hung Nguyen, Hung Trong Hoang","doi":"10.1038/s41405-025-00303-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to create a 3D-printed customized transfer key and evaluate the accuracy of the virtual patient model with maxillomandibular relationship at centric occlusion using the transfer key.</p><p><strong>Methods: </strong>A 3D-printed transfer key was designed, combining facial and intraoral (IOS) scans. The design included components that recorded the 3D upper and lower arch at centric occlusion. The virtual patient model image was generated in-vitro using a phantom head with soft tissue simulation. Accuracy was assessed by superimposing the 3D scans with reference CBCT images and analyzing trueness and precision using root mean square (RMS) deviations.</p><p><strong>Results: </strong>The transfer key included an intra-oral part that acts as an anterior deprogrammer to record the relationship of two dental arches at centric occlusion (CO) and an extra-oral with a rotatable cross-shaped design with two arms for locating the facial midline and the two pupils connecting line. Superimposition demonstrated high trueness (RMS: 0.51 mm for the arch regions, 0.69 mm for the whole head region, 0.85 mm in the face region) and precision (RMS: 0.41 mm for the arch regions, 0.52 mm for the entire head, 0.63 mm in the face region) significantly (p < 0.05). Minimal deviations were observed in critical areas, including the tooth and lip position, indicating that the virtual patient model was closely aligned with the CBCT reference. The dental arches achieved the highest accuracy, while slight deviations were noted in the facial regions.</p><p><strong>Conclusions: </strong>The 3D-printed customized transfer key effectively enhanced the virtual patient model's accuracy, surpassing traditional trueness and precision methods. This novel approach offers a streamlined, patient-friendly solution for digital dental workflows.</p>","PeriodicalId":36997,"journal":{"name":"BDJ Open","volume":"11 1","pages":"8"},"PeriodicalIF":2.5000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11785937/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BDJ Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s41405-025-00303-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This study aimed to create a 3D-printed customized transfer key and evaluate the accuracy of the virtual patient model with maxillomandibular relationship at centric occlusion using the transfer key.

Methods: A 3D-printed transfer key was designed, combining facial and intraoral (IOS) scans. The design included components that recorded the 3D upper and lower arch at centric occlusion. The virtual patient model image was generated in-vitro using a phantom head with soft tissue simulation. Accuracy was assessed by superimposing the 3D scans with reference CBCT images and analyzing trueness and precision using root mean square (RMS) deviations.

Results: The transfer key included an intra-oral part that acts as an anterior deprogrammer to record the relationship of two dental arches at centric occlusion (CO) and an extra-oral with a rotatable cross-shaped design with two arms for locating the facial midline and the two pupils connecting line. Superimposition demonstrated high trueness (RMS: 0.51 mm for the arch regions, 0.69 mm for the whole head region, 0.85 mm in the face region) and precision (RMS: 0.41 mm for the arch regions, 0.52 mm for the entire head, 0.63 mm in the face region) significantly (p < 0.05). Minimal deviations were observed in critical areas, including the tooth and lip position, indicating that the virtual patient model was closely aligned with the CBCT reference. The dental arches achieved the highest accuracy, while slight deviations were noted in the facial regions.

Conclusions: The 3D-printed customized transfer key effectively enhanced the virtual patient model's accuracy, surpassing traditional trueness and precision methods. This novel approach offers a streamlined, patient-friendly solution for digital dental workflows.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BDJ Open
BDJ Open Dentistry-Dentistry (all)
CiteScore
3.70
自引率
3.30%
发文量
34
审稿时长
30 weeks
期刊最新文献
Effects of mixing of europium oxide in resin composites on the fluorescence characteristics and mechanical properties. Regenerative potential of concentrated growth factor compared to platelet-rich fibrin in treatment of necrotic mature teeth: a randomized clinical trial. In-vitro accuracy of the virtual patient model with maxillomandibular relationship at centric occlusion using 3D-printed customized transfer key. Efficacy of oral irrigators compared to other interdental aids for managing peri-implant diseases: a systematic review. Influence of two different printing methods on the accuracy of full-guided implant insertion - a laboratory study in undergraduate dental students.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1