Effects of preparation design on the marginal and internal fit of CAD-CAM overlay restorations: A µCT evaluation

IF 4.8 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2025-04-01 Epub Date: 2025-02-01 DOI:10.1016/j.prosdent.2024.12.023
Edoardo Mancuso PhD , Annamaria Forte DDS , Tatjana Maravic PhD , Claudia Mazzitelli PhD , Allegra Comba PhD , Andrea Baldi PhD , Vincent Fehmer , Irena Sailer PhD , Nicola Scotti PhD , Annalisa Mazzoni PhD , Prof Lorenzo Breschi PhD
{"title":"Effects of preparation design on the marginal and internal fit of CAD-CAM overlay restorations: A µCT evaluation","authors":"Edoardo Mancuso PhD ,&nbsp;Annamaria Forte DDS ,&nbsp;Tatjana Maravic PhD ,&nbsp;Claudia Mazzitelli PhD ,&nbsp;Allegra Comba PhD ,&nbsp;Andrea Baldi PhD ,&nbsp;Vincent Fehmer ,&nbsp;Irena Sailer PhD ,&nbsp;Nicola Scotti PhD ,&nbsp;Annalisa Mazzoni PhD ,&nbsp;Prof Lorenzo Breschi PhD","doi":"10.1016/j.prosdent.2024.12.023","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>The effects of different finish line designs on the seating accuracy of partial indirect restorations are unclear.</div></div><div><h3>Purpose</h3><div>The purpose of this in vitro study was to evaluate the influence of different preparation designs on the marginal and internal discrepancy of lithium disilicate computer-aided design and computer-aided manufacture (CAD-CAM) partial indirect restorations before and after thermomechanical aging by using 3-dimensional (3D) microcomputed tomography (μCT).</div></div><div><h3>Material and methods</h3><div>Forty human molars were divided according to the preparation design and their location relative to the tooth survey line: SO: rounded shoulder occlusal to the survey line; CO: chamfer occlusal to the survey line; SA: rounded shoulder apical to the survey line; CA: chamfer apical to the survey line (n=10). Ceramic onlays were luted using a universal resin cement (RelyX Universal + Scotchbond Universal Plus). The specimens underwent thermomechanical loading in a mastication simulator (1 200 000 mechanical and 5000 thermal cycles). The marginal and internal discrepancy was evaluated with μCT before and after aging. The volume of cement and internal voids was evaluated with 3-dimensional imaging. The marginal discrepancy (MD), absolute marginal discrepancy (AMD), axial gap (AG), and occlusal gap (OG) were quantified using 2-dimensional analyses. Data were statistically analyzed using a 2-way ANOVA and the Tukey post hoc test (α=.05).</div></div><div><h3>Results</h3><div>Preparation designs apical to the survey line resulted in a larger volume of cement compared with those occlusal to the survey line (<em>P</em>&lt;.05). No differences were observed in the internal voids among the groups immediately or after aging (<em>P</em>&gt;.05). Both preparation designs and aging had a significant influence on the MD, AMD, AG, and OG (<em>P</em>&lt;.05). Specifically, CB exhibited significantly greater values for AMD, MD, AG, and OG compared with all other preparations (<em>P</em>&lt;.05). CA and SA performed significantly worse than CO and SO in terms of AMD and MD (<em>P</em>&lt;.005).</div></div><div><h3>Conclusions</h3><div>Preparations located occlusal to the survey line, particularly CO, demonstrated superior results with respect to both marginal and internal adaptations. CA exhibited the least favorable adaptation among the preparations investigated. Aging had a detrimental impact on the marginal adaptation of the restorations, regardless of the specific preparation design used.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"133 4","pages":"Pages 1055.e1-1055.e10"},"PeriodicalIF":4.8000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391325000071","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

The effects of different finish line designs on the seating accuracy of partial indirect restorations are unclear.

Purpose

The purpose of this in vitro study was to evaluate the influence of different preparation designs on the marginal and internal discrepancy of lithium disilicate computer-aided design and computer-aided manufacture (CAD-CAM) partial indirect restorations before and after thermomechanical aging by using 3-dimensional (3D) microcomputed tomography (μCT).

Material and methods

Forty human molars were divided according to the preparation design and their location relative to the tooth survey line: SO: rounded shoulder occlusal to the survey line; CO: chamfer occlusal to the survey line; SA: rounded shoulder apical to the survey line; CA: chamfer apical to the survey line (n=10). Ceramic onlays were luted using a universal resin cement (RelyX Universal + Scotchbond Universal Plus). The specimens underwent thermomechanical loading in a mastication simulator (1 200 000 mechanical and 5000 thermal cycles). The marginal and internal discrepancy was evaluated with μCT before and after aging. The volume of cement and internal voids was evaluated with 3-dimensional imaging. The marginal discrepancy (MD), absolute marginal discrepancy (AMD), axial gap (AG), and occlusal gap (OG) were quantified using 2-dimensional analyses. Data were statistically analyzed using a 2-way ANOVA and the Tukey post hoc test (α=.05).

Results

Preparation designs apical to the survey line resulted in a larger volume of cement compared with those occlusal to the survey line (P<.05). No differences were observed in the internal voids among the groups immediately or after aging (P>.05). Both preparation designs and aging had a significant influence on the MD, AMD, AG, and OG (P<.05). Specifically, CB exhibited significantly greater values for AMD, MD, AG, and OG compared with all other preparations (P<.05). CA and SA performed significantly worse than CO and SO in terms of AMD and MD (P<.005).

Conclusions

Preparations located occlusal to the survey line, particularly CO, demonstrated superior results with respect to both marginal and internal adaptations. CA exhibited the least favorable adaptation among the preparations investigated. Aging had a detrimental impact on the marginal adaptation of the restorations, regardless of the specific preparation design used.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
制备设计对CAD-CAM覆盖修复体边缘和内部配合的影响:微CT评估。
问题陈述:不同的终点线设计对部分间接修复的座位精度的影响尚不清楚。目的:利用三维(3D)微计算机断层扫描(μCT)研究不同制备设计对二硅酸锂计算机辅助设计和计算机辅助制造(CAD-CAM)局部间接修复体在热机械老化前后的边缘和内部差异的影响。材料与方法:将40颗人磨牙按其相对于牙齿调查线的位置进行划分:SO:圆肩咬合于牙齿调查线;CO:倒角咬合测量线;SA:圆肩顶点至测量线;CA:倒角顶点指向测量线(n=10)。使用通用树脂水泥(RelyX universal + Scotchbond universal Plus)对陶瓷衬垫进行粘合。试件在咀嚼模拟器中进行了热力加载(120万次机械循环和5000次热循环)。老化前后用μCT评价边缘差异和内部差异。通过三维成像评估骨水泥和内部空隙的体积。采用二维分析对边缘差异(MD)、绝对边缘差异(AMD)、轴向间隙(AG)和咬合间隙(OG)进行量化。数据采用双因素方差分析和Tukey事后检验进行统计学分析(α= 0.05)。结果:与与测量线咬合的骨水泥相比,与测量线咬合的骨水泥体积更大(p < 0.05)。制剂设计和老化对MD、AMD、AG和OG均有显著影响(p)。结论:位于测量线咬合处的制剂,特别是CO,在边缘和内部适应方面均表现出优越的结果。CA的适应性最差。老化对修复体的边缘适应性有不利影响,无论使用何种特定的制备设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
A simulation-based study of 3D printing angle optimization by integrating deep learning and NSGA-III for prosthesis and retainer manufacturing. Molar socket shield technique with immediate implant placement maintains stable tissue architecture at 5- to 7-year follow-up: A clinical series. Influence of aging and manufacturing techniques on the physical and mechanical stability of occlusal device materials: A systematic review. Screw preload analysis of direct-to-abutment connections in complete arch zirconia frameworks before and after thermomechanical aging. Clinical evaluation of retention and patient satisfaction of monolithic complete denture: A crossover controlled clinical trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1