A case of aseptic loosening after total knee replacement with porous-coated mega prosthesis despite progression of extra bone growth

Q4 Medicine Radiology Case Reports Pub Date : 2025-04-01 Epub Date: 2025-01-18 DOI:10.1016/j.radcr.2025.01.019
Ryota Miyamoto MD , Yasushi Goto MD , Toshitaka Fujito MD, PhD , Hirohito Abe MD, PhD , Yasuo Kunugiza MD, PhD
{"title":"A case of aseptic loosening after total knee replacement with porous-coated mega prosthesis despite progression of extra bone growth","authors":"Ryota Miyamoto MD ,&nbsp;Yasushi Goto MD ,&nbsp;Toshitaka Fujito MD, PhD ,&nbsp;Hirohito Abe MD, PhD ,&nbsp;Yasuo Kunugiza MD, PhD","doi":"10.1016/j.radcr.2025.01.019","DOIUrl":null,"url":null,"abstract":"<div><div>Total knee replacement with mega prosthesis for periprosthetic fractures after total knee arthroplasty is related to early functional recovery, but aseptic loosening of the implant has been a major reoperation factor in the long-term outcome of total knee replacement with mega prosthesis. Extracortical bone formation caused by bone-collar interface osteointegration may decrease the probability of aseptic loosening by promoting bone formation and improving bone-implant fixation. Here, we report a case of total knee replacement using mega prosthesis with porous-coated collar showing extra bone growth without osteointegration of prosthesis and leading to aseptic loosening.</div></div>","PeriodicalId":53472,"journal":{"name":"Radiology Case Reports","volume":"20 4","pages":"Pages 1900-1903"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11786797/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1930043325000214","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/18 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Total knee replacement with mega prosthesis for periprosthetic fractures after total knee arthroplasty is related to early functional recovery, but aseptic loosening of the implant has been a major reoperation factor in the long-term outcome of total knee replacement with mega prosthesis. Extracortical bone formation caused by bone-collar interface osteointegration may decrease the probability of aseptic loosening by promoting bone formation and improving bone-implant fixation. Here, we report a case of total knee replacement using mega prosthesis with porous-coated collar showing extra bone growth without osteointegration of prosthesis and leading to aseptic loosening.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全膝关节置换术后无菌性松动一例,尽管有额外骨生长的进展。
全膝关节置换术后假体周围骨折采用巨型假体全膝关节置换术与早期功能恢复有关,但无菌性假体松动一直是巨型假体全膝关节置换术长期预后的主要再手术因素。骨-领界面骨整合引起的牙外骨形成可能通过促进骨形成和改善骨-种植体固定来减少无菌性松动的可能性。在此,我们报告一例全膝关节置换术,采用多孔涂层假体的巨型假体,在假体骨未整合的情况下出现额外的骨生长,并导致无菌性松动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiology Case Reports
Radiology Case Reports Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.10
自引率
0.00%
发文量
1074
审稿时长
30 days
期刊介绍: The content of this journal is exclusively case reports that feature diagnostic imaging. Categories in which case reports can be placed include the musculoskeletal system, spine, central nervous system, head and neck, cardiovascular, chest, gastrointestinal, genitourinary, multisystem, pediatric, emergency, women''s imaging, oncologic, normal variants, medical devices, foreign bodies, interventional radiology, nuclear medicine, molecular imaging, ultrasonography, imaging artifacts, forensic, anthropological, and medical-legal. Articles must be well-documented and include a review of the appropriate literature.
期刊最新文献
Cervical embryonal rhabdomyosarcoma beyond childhood: A case report and literature review Obstructive hydrocephalus secondary to an anterior mesencephalic cavernous malformation with familial cerebral cavernous malformation syndrome: A case report Gallbladder mucinous cystic neoplasm: Diagnostic challenges and multimodality imaging correlation Solitary intracranial dural-based Ewing’s sarcoma in a pregnant female: A case report Retained Microcatheter During n-Butyl Cyanoacrylate Embolization of a Ruptured Distal Posterior Cerebral Artery Aneurysm: A Case Report With 4-Year Follow-Up
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1