Hemostatic efficacy evaluation and safety profile of a cellulose nanofiber mat

IF 6.5 Q1 CHEMISTRY, APPLIED Carbohydrate Polymer Technologies and Applications Pub Date : 2025-03-01 Epub Date: 2024-12-03 DOI:10.1016/j.carpta.2024.100628
Enhui Lin , Osman Asila , Sangchul Rho , Ju Hong Park , Dong Soo Hwang
{"title":"Hemostatic efficacy evaluation and safety profile of a cellulose nanofiber mat","authors":"Enhui Lin ,&nbsp;Osman Asila ,&nbsp;Sangchul Rho ,&nbsp;Ju Hong Park ,&nbsp;Dong Soo Hwang","doi":"10.1016/j.carpta.2024.100628","DOIUrl":null,"url":null,"abstract":"<div><div>Although the hemostatically efficacious nature of cellulose nanofibers (CNFs) is well established, data regarding their hemostatic performance in large animal systems and safety toward human skin cells, which are critical factors for clinical translation, are lacking. This study evaluated the clinical potential of CNF-coated gauze by testing its hemostatic efficacy in rats, rabbits, and pigs, and assessing its safety in human primary cells through differential gene expression (DEG) analysis. <em>In-vitro</em> studies using rabbit blood revealed that the CNF-coated gauze exhibited a significantly lower blood clotting index (BCI) value than gauze coated with chitosan, a commonly used hemostatic agent, indicating superior blood clotting. <em>In-vivo</em> tests on bleeding-induced pig livers revealed that the CNF-coated gauze delivered a four-fold higher hemostatic success rate reduced bleeding volume compared to regular gauze. Moreover, a rat wound-healing model revealed improved healing with CNF-coated gauze. DEG analysis of human dermal fibroblast primary cells showed no statistically significant differences between the CNF and control groups, indicating its human safety. Overall, our results suggest that CNF-coated hemostatic gauze absorbs blood rapidly, delivers superior hemostatic performance compared to regular gauze, is safe from both histological and DEG perspectives, and is therefore suitable for use in healthcare and clinical settings.</div></div>","PeriodicalId":100213,"journal":{"name":"Carbohydrate Polymer Technologies and Applications","volume":"9 ","pages":"Article 100628"},"PeriodicalIF":6.5000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Carbohydrate Polymer Technologies and Applications","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666893924002081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

Although the hemostatically efficacious nature of cellulose nanofibers (CNFs) is well established, data regarding their hemostatic performance in large animal systems and safety toward human skin cells, which are critical factors for clinical translation, are lacking. This study evaluated the clinical potential of CNF-coated gauze by testing its hemostatic efficacy in rats, rabbits, and pigs, and assessing its safety in human primary cells through differential gene expression (DEG) analysis. In-vitro studies using rabbit blood revealed that the CNF-coated gauze exhibited a significantly lower blood clotting index (BCI) value than gauze coated with chitosan, a commonly used hemostatic agent, indicating superior blood clotting. In-vivo tests on bleeding-induced pig livers revealed that the CNF-coated gauze delivered a four-fold higher hemostatic success rate reduced bleeding volume compared to regular gauze. Moreover, a rat wound-healing model revealed improved healing with CNF-coated gauze. DEG analysis of human dermal fibroblast primary cells showed no statistically significant differences between the CNF and control groups, indicating its human safety. Overall, our results suggest that CNF-coated hemostatic gauze absorbs blood rapidly, delivers superior hemostatic performance compared to regular gauze, is safe from both histological and DEG perspectives, and is therefore suitable for use in healthcare and clinical settings.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
纤维素纳米纤维垫止血效果评价及安全性分析
尽管纤维素纳米纤维(CNFs)的止血效果已经得到了很好的证实,但关于其在大型动物系统中的止血性能和对人体皮肤细胞的安全性(这是临床转化的关键因素)的数据还很缺乏。本研究通过在大鼠、家兔和猪身上测试其止血效果,并通过差异基因表达(DEG)分析评估其在人原代细胞中的安全性,来评估cnf包被纱布的临床潜力。兔血体外实验表明,cnf包被纱布的凝血指数(BCI)值明显低于壳聚糖包被纱布,表明其凝血效果更好。对猪肝脏出血的体内试验表明,与普通纱布相比,cnf涂层纱布的止血成功率高4倍,出血量减少。此外,大鼠伤口愈合模型显示cnf涂层纱布改善愈合。人真皮成纤维原代细胞的DEG分析显示,CNF与对照组之间无统计学差异,表明其人体安全性。总的来说,我们的研究结果表明,cnf涂层止血纱布吸收血液速度快,与普通纱布相比具有优越的止血性能,从组织学和DEG角度来看都是安全的,因此适合在医疗保健和临床环境中使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.70
自引率
0.00%
发文量
0
期刊最新文献
Structure–kinetics relationships in β-cyclodextrin metal–organic frameworks for selective volatile bioactive delivery Comprehensive structural characterization of pectin, arabinan and galactan from Gentiana purpurea L. roots and their immunostimulatory effects Chitosan enhances antimicrobial efficiency of ceftazidime against Burkholderia pseudomallei in an ex vivo skin model and cellular infections Physicochemical and structural study of iodine loading in amorphous degradable starch microspheres Compatibilization strategies and mechanical performances of starch-based blends for sustainable packaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1