{"title":"Enhanced post-fault recovery in MTDC networks using active damping approach","authors":"Monika Sharma, José L. Rueda Torres","doi":"10.1049/gtd2.13321","DOIUrl":null,"url":null,"abstract":"<p>The increasing deployment of offshore wind farms necessitates robust and stable high-voltage direct current networks. Achieving optimal stability, especially in damping oscillations on the DC side, remains a significant challenge. This study focuses on mitigating post-fault converter de-blocking oscillations, a critical issue exacerbated by complex interactions between AC and DC systems, converter dynamics, and system faults. These behavior are governed by nonlinear system dynamics, making traditional control methods less effective in ensuring stability. A comprehensive analysis of DC side oscillations and their interaction with converter dynamics is developed to understand the key factors influencing system stability. The research investigates a DC voltage regulation damping approach, identified as the most effective solution in the literature. Comprehensive parametric sensitivity analysis evaluates system behavior under diverse operational conditions. Addressing current damping method limitations during converter de-blocking, this work proposes an innovative control approach integrating fuzzy logic control and proportional–integral controllers. This approach enhances DC voltage regulation and incorporates a modified circulating current suppression control in the inner loop. The coordinated fuzzy logic control and proportional–integral controller dynamically adjusts to nonlinear system dynamics in real-time, providing a robust framework for improved post-fault recovery. It aims to achieve faster recovery times and reduced overshoot compared to conventional methods. The proposed controller's efficacy is validated through comparative analysis with existing approaches. Electromagnetic transient) simulations using the real-time digital simulator platform demonstrate the controller's performance under realistic operating conditions.</p>","PeriodicalId":13261,"journal":{"name":"Iet Generation Transmission & Distribution","volume":"19 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/gtd2.13321","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Generation Transmission & Distribution","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/gtd2.13321","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
The increasing deployment of offshore wind farms necessitates robust and stable high-voltage direct current networks. Achieving optimal stability, especially in damping oscillations on the DC side, remains a significant challenge. This study focuses on mitigating post-fault converter de-blocking oscillations, a critical issue exacerbated by complex interactions between AC and DC systems, converter dynamics, and system faults. These behavior are governed by nonlinear system dynamics, making traditional control methods less effective in ensuring stability. A comprehensive analysis of DC side oscillations and their interaction with converter dynamics is developed to understand the key factors influencing system stability. The research investigates a DC voltage regulation damping approach, identified as the most effective solution in the literature. Comprehensive parametric sensitivity analysis evaluates system behavior under diverse operational conditions. Addressing current damping method limitations during converter de-blocking, this work proposes an innovative control approach integrating fuzzy logic control and proportional–integral controllers. This approach enhances DC voltage regulation and incorporates a modified circulating current suppression control in the inner loop. The coordinated fuzzy logic control and proportional–integral controller dynamically adjusts to nonlinear system dynamics in real-time, providing a robust framework for improved post-fault recovery. It aims to achieve faster recovery times and reduced overshoot compared to conventional methods. The proposed controller's efficacy is validated through comparative analysis with existing approaches. Electromagnetic transient) simulations using the real-time digital simulator platform demonstrate the controller's performance under realistic operating conditions.
期刊介绍:
IET Generation, Transmission & Distribution is intended as a forum for the publication and discussion of current practice and future developments in electric power generation, transmission and distribution. Practical papers in which examples of good present practice can be described and disseminated are particularly sought. Papers of high technical merit relying on mathematical arguments and computation will be considered, but authors are asked to relegate, as far as possible, the details of analysis to an appendix.
The scope of IET Generation, Transmission & Distribution includes the following:
Design of transmission and distribution systems
Operation and control of power generation
Power system management, planning and economics
Power system operation, protection and control
Power system measurement and modelling
Computer applications and computational intelligence in power flexible AC or DC transmission systems
Special Issues. Current Call for papers:
Next Generation of Synchrophasor-based Power System Monitoring, Operation and Control - https://digital-library.theiet.org/files/IET_GTD_CFP_NGSPSMOC.pdf