Automated capillary electrophoresis analyses of dried blood samples after patient-centric volumetric absorptive microsampling

IF 5.2 Q1 CHEMISTRY, ANALYTICAL Advances in Sample Preparation Pub Date : 2025-02-01 DOI:10.1016/j.sampre.2024.100142
Richard Maršala , Miloš Dvořák , Pavel Kubáň
{"title":"Automated capillary electrophoresis analyses of dried blood samples after patient-centric volumetric absorptive microsampling","authors":"Richard Maršala ,&nbsp;Miloš Dvořák ,&nbsp;Pavel Kubáň","doi":"10.1016/j.sampre.2024.100142","DOIUrl":null,"url":null,"abstract":"<div><div>An automated method for the analysis of dried blood samples collected by volumetric absorptive microsampling (VAMS) is presented for the first time. A single commercial capillary electrophoresis (CE) instrument (with no need for hardware or software modifications) was employed for the expeditious analyses of the dried material using several integral and novel features. These included the use of external pressure for sub-minute sample preparation from Mitra® VAMS polymeric tips, the use of the sampling tips as inherent micro-agitators for instant eluate homogenization, preparation/sampling at the CE outlet for more convenient capillary length adjustment, and short-end injection for sub-minute CE separation and quantification of lactate as a model analyte.</div><div>The operational parameters for the sample preparation and analysis were comprehensively evaluated resulting in a baseline separation of lactate from all endogenous matrix compounds. The optimized method demonstrated excellent intra- and inter-day repeatability of peak areas (RSD values ≤ 7.2 %), linearity (R² = 0.9990) over the clinically relevant concentration range (0.15 – 20 mM), the limits of detection and quantification at 0.03 and 0.1 mM, respectively, and a sample throughput ≥ 16 samples/hour. No ageing was observed for VAMS devices stored at ambient conditions for up to 14 days. Comparative analysis with a portable lactate analyser revealed slightly elevated concentrations in dried vs. liquid capillary blood due to the glycolysis of glucose during drying, nevertheless, lactate concentrations in Mitra® devices correlated well with those in blood plasma, which is typically used in clinical practice.</div><div>The present study offers a robust, accurate, and environmentally benign concept for the automated analyses of VAMS-collected blood samples with its potential application in patient-centric sampling, clinical diagnostics and research, and personalized healthcare.</div></div>","PeriodicalId":100052,"journal":{"name":"Advances in Sample Preparation","volume":"13 ","pages":"Article 100142"},"PeriodicalIF":5.2000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Sample Preparation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772582024000391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

An automated method for the analysis of dried blood samples collected by volumetric absorptive microsampling (VAMS) is presented for the first time. A single commercial capillary electrophoresis (CE) instrument (with no need for hardware or software modifications) was employed for the expeditious analyses of the dried material using several integral and novel features. These included the use of external pressure for sub-minute sample preparation from Mitra® VAMS polymeric tips, the use of the sampling tips as inherent micro-agitators for instant eluate homogenization, preparation/sampling at the CE outlet for more convenient capillary length adjustment, and short-end injection for sub-minute CE separation and quantification of lactate as a model analyte.
The operational parameters for the sample preparation and analysis were comprehensively evaluated resulting in a baseline separation of lactate from all endogenous matrix compounds. The optimized method demonstrated excellent intra- and inter-day repeatability of peak areas (RSD values ≤ 7.2 %), linearity (R² = 0.9990) over the clinically relevant concentration range (0.15 – 20 mM), the limits of detection and quantification at 0.03 and 0.1 mM, respectively, and a sample throughput ≥ 16 samples/hour. No ageing was observed for VAMS devices stored at ambient conditions for up to 14 days. Comparative analysis with a portable lactate analyser revealed slightly elevated concentrations in dried vs. liquid capillary blood due to the glycolysis of glucose during drying, nevertheless, lactate concentrations in Mitra® devices correlated well with those in blood plasma, which is typically used in clinical practice.
The present study offers a robust, accurate, and environmentally benign concept for the automated analyses of VAMS-collected blood samples with its potential application in patient-centric sampling, clinical diagnostics and research, and personalized healthcare.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
0
期刊最新文献
Determination of acylcarnitines in intact brain tumors using coated blade spray mass spectrometry (CBS-MS) Endogenous HiBiT-tagging combined with affinity complementation: A new strategy for small open reading frame-encoded polypeptide detection in bacteria Automated capillary electrophoresis analyses of dried blood samples after patient-centric volumetric absorptive microsampling Polydopamine-graphene oxide aerogel for in-tube solid-phase microextraction of polycyclic aromatic hydrocarbons Vial-coated thin film microextraction for perfluoroalkyl carboxylic acids (PFCAs) determination in water by GC–MS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1