Assessment of Cerenkov optical noise in a brachytherapy scintillating fibre dosimeter with an air-core Ag-PTFE light guide

IF 1.6 3区 物理与天体物理 Q2 NUCLEAR SCIENCE & TECHNOLOGY Radiation Measurements Pub Date : 2025-02-01 DOI:10.1016/j.radmeas.2024.107348
Nor El Houda Boughaba , Boualem Bouzid , Nadia Yahlali
{"title":"Assessment of Cerenkov optical noise in a brachytherapy scintillating fibre dosimeter with an air-core Ag-PTFE light guide","authors":"Nor El Houda Boughaba ,&nbsp;Boualem Bouzid ,&nbsp;Nadia Yahlali","doi":"10.1016/j.radmeas.2024.107348","DOIUrl":null,"url":null,"abstract":"<div><div>Plastic scintillating fibre dosimeters have been the subject of multiple studies in the field of medical dosimetry, due to their notable dosimetric properties, including water equivalence, small size and absence of energy and dose rate dependence. The main drawback of this dosimeter type in high dose-rate brachytherapy is the presence of Cerenkov photons produced by electrons with velocities exceeding the speed of light in the fibre plastic medium. In this work, aimed at minimizing Cerenkov noise at its source in a prototype scintillation fibre dosimeter, the plastic light guide exposed to the radiation field was replaced by an air-core Ag-PTFE light guide of miniature size. Cerenkov-to-signal ratio was first assessed in fibre bundles using a dedicated experimental setup and simulations. This ratio was found of about <span><math><mrow><mo>∼</mo><mn>1</mn></mrow></math></span> <span><math><mtext>%</mtext></math></span> for scintillating fibres when exposed to radiation in the energy range 1–2 MeV. The performance of the air-core Ag-PTFE light guide dosimeter was then studied, resulting in a decrease of the Cerenkov light in the total signal from <span><math><mrow><mo>∼</mo><mn>50</mn></mrow></math></span> <span><math><mtext>%</mtext></math></span> to less than 0.3%, compared to the standard dosimeter with a plastic optical light guide. The counterpart of this substantial reduction of optical noise is a reduction of 40% in the dosimeter light collection efficiency. However, this is not a limiting feature of this Cerenkov-free dosimeter, since further optical optimizations are possible, in addition to the use of a high-gain and high-sensitivity photodetector for its readout.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"181 ","pages":"Article 107348"},"PeriodicalIF":1.6000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448724002968","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Plastic scintillating fibre dosimeters have been the subject of multiple studies in the field of medical dosimetry, due to their notable dosimetric properties, including water equivalence, small size and absence of energy and dose rate dependence. The main drawback of this dosimeter type in high dose-rate brachytherapy is the presence of Cerenkov photons produced by electrons with velocities exceeding the speed of light in the fibre plastic medium. In this work, aimed at minimizing Cerenkov noise at its source in a prototype scintillation fibre dosimeter, the plastic light guide exposed to the radiation field was replaced by an air-core Ag-PTFE light guide of miniature size. Cerenkov-to-signal ratio was first assessed in fibre bundles using a dedicated experimental setup and simulations. This ratio was found of about 1 % for scintillating fibres when exposed to radiation in the energy range 1–2 MeV. The performance of the air-core Ag-PTFE light guide dosimeter was then studied, resulting in a decrease of the Cerenkov light in the total signal from 50 % to less than 0.3%, compared to the standard dosimeter with a plastic optical light guide. The counterpart of this substantial reduction of optical noise is a reduction of 40% in the dosimeter light collection efficiency. However, this is not a limiting feature of this Cerenkov-free dosimeter, since further optical optimizations are possible, in addition to the use of a high-gain and high-sensitivity photodetector for its readout.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation Measurements
Radiation Measurements 工程技术-核科学技术
CiteScore
4.10
自引率
20.00%
发文量
116
审稿时长
48 days
期刊介绍: The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal. Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.
期刊最新文献
Editorial Board Development of A handheld pressurized ionization chamber for gamma monitoring Three-dimensional electron paramagnetic resonance (EPR) imaging of an X-ray-irradiated bovine tooth: A feasibility study Compton-camera-based radiopharmaceutical imaging with an attenuation-corrected LM-MLEM reconstruction strategy Feasibility study on dose conversion using a deep learning algorithm for retrospective dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1