Investigation of the effect of crystal dead layer on system performance in Single Photon Emission Computed Tomography: A Monte Carlo simulation study

IF 1.6 3区 物理与天体物理 Q2 NUCLEAR SCIENCE & TECHNOLOGY Radiation Measurements Pub Date : 2025-02-01 DOI:10.1016/j.radmeas.2024.107363
Hilal Uslu Aynur , Tuncay Bayram , Anes Hayder , Sonay Gedik
{"title":"Investigation of the effect of crystal dead layer on system performance in Single Photon Emission Computed Tomography: A Monte Carlo simulation study","authors":"Hilal Uslu Aynur ,&nbsp;Tuncay Bayram ,&nbsp;Anes Hayder ,&nbsp;Sonay Gedik","doi":"10.1016/j.radmeas.2024.107363","DOIUrl":null,"url":null,"abstract":"<div><div>One of the factors affecting image quality in SPECT (Single Photon Emission Computed Tomography) applications is the dead layer that forms over time in the scintillation crystal. In this study, we aimed to investigate the effect of dead layers in the NaI(Tl) scintillation crystal used in SPECT on system performance. The GATE simulation code, which is based on the GEANT4 toolkit and is widely recognized for its application in nuclear imaging simulations, was employed for this investigation. In the first step, the standard SPECT model was simulated, and the SPECT performance parameters (sensitivity, spatial resolution, energy resolution, and contrast) for low 140 keV (for <span><math><msup><mrow></mrow><mrow><mn>99</mn><mi>m</mi></mrow></msup></math></span>Tc), medium 167 keV (for <sup>201</sup>Tl), and high 364 keV (for <sup>131</sup>I) gamma energies have been analyzed. Then, various thicknesses of dead layers on the crystal were simulated, and the effect of the dead layer on the performance parameters was evaluated for the same energies. The results indicate a reduction in SPECT sensitivity of approximately 33.5%, 27.1%, and 21.7% for low, medium, and high energies, respectively, as the thickness of the crystal’s dead layer increases from 0.19 mm to 1.52 mm (equivalent to 2% to 16%). Small deteriorations in spatial resolution and energy resolution of the SPECT have been determined for 140 keV, 167 keV, and 364 keV gamma energies. The dead layers slightly influenced the contrast of SPECT. The results of this study show that the image quality assessment parameters of the SPECT system deteriorated as the thickness of the scintillation crystal’s dead layer increased.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"181 ","pages":"Article 107363"},"PeriodicalIF":1.6000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448724003111","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

One of the factors affecting image quality in SPECT (Single Photon Emission Computed Tomography) applications is the dead layer that forms over time in the scintillation crystal. In this study, we aimed to investigate the effect of dead layers in the NaI(Tl) scintillation crystal used in SPECT on system performance. The GATE simulation code, which is based on the GEANT4 toolkit and is widely recognized for its application in nuclear imaging simulations, was employed for this investigation. In the first step, the standard SPECT model was simulated, and the SPECT performance parameters (sensitivity, spatial resolution, energy resolution, and contrast) for low 140 keV (for 99mTc), medium 167 keV (for 201Tl), and high 364 keV (for 131I) gamma energies have been analyzed. Then, various thicknesses of dead layers on the crystal were simulated, and the effect of the dead layer on the performance parameters was evaluated for the same energies. The results indicate a reduction in SPECT sensitivity of approximately 33.5%, 27.1%, and 21.7% for low, medium, and high energies, respectively, as the thickness of the crystal’s dead layer increases from 0.19 mm to 1.52 mm (equivalent to 2% to 16%). Small deteriorations in spatial resolution and energy resolution of the SPECT have been determined for 140 keV, 167 keV, and 364 keV gamma energies. The dead layers slightly influenced the contrast of SPECT. The results of this study show that the image quality assessment parameters of the SPECT system deteriorated as the thickness of the scintillation crystal’s dead layer increased.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation Measurements
Radiation Measurements 工程技术-核科学技术
CiteScore
4.10
自引率
20.00%
发文量
116
审稿时长
48 days
期刊介绍: The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal. Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.
期刊最新文献
Editorial Board Development of A handheld pressurized ionization chamber for gamma monitoring Three-dimensional electron paramagnetic resonance (EPR) imaging of an X-ray-irradiated bovine tooth: A feasibility study Compton-camera-based radiopharmaceutical imaging with an attenuation-corrected LM-MLEM reconstruction strategy Feasibility study on dose conversion using a deep learning algorithm for retrospective dosimetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1