{"title":"Radon exhalation rate from the latex pillows and its potential exposure to users","authors":"Phachirarat Sola ,&nbsp;Kanokporn Boonsirichai ,&nbsp;Santi Raksawong ,&nbsp;Ritiron Samran ,&nbsp;Pimprapa Chaijak ,&nbsp;Hirofumi Tazoe ,&nbsp;Chutima Kranrod ,&nbsp;Rawiwan Kritsananuwat ,&nbsp;Sattawat Jongjitklang ,&nbsp;Vichai Puripunyavanich ,&nbsp;Masahiro Hosoda ,&nbsp;Waleeporn Pongkua ,&nbsp;Shinji Tokonami","doi":"10.1016/j.radmp.2024.09.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>To develop a new system to accurately measure the radon exhalation from the latex pillows, and to estimate its potential exposure to users.</div></div><div><h3>Methods</h3><div>The new system is composed of two loops, the first loop is designed to trap background radon and thoron until their levels are nearly zero, and the second loop is the measurement loop to detect radon and thoron exhalation rates from the pillows.</div></div><div><h3>Results</h3><div>The results showed that mass radon exhalation rated ranged from 0.18 Bq·kg<sup>−1</sup>⋅h<sup>−1</sup> to 0.78 Bq·kg<sup>−1</sup>⋅h<sup>−1</sup>, with an average of (0.36 ​± ​0.17) Bq·kg<sup>−1</sup>⋅h<sup>−1</sup> in the 9 samples. The average annual effective dose to users in a model room was estimated to be (15.51 ​± ​12.69) μSv by assuming two pillows was used.</div></div><div><h3>Conclusion</h3><div>These results demonstrate that the new system can effectively measure radon exhalation rates in latex pillows, and the potential exposure to radon exhalating from the pillows is very low.</div></div>","PeriodicalId":34051,"journal":{"name":"Radiation Medicine and Protection","volume":"5 4","pages":"Pages 238-242"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Medicine and Protection","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666555724000790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To develop a new system to accurately measure the radon exhalation from the latex pillows, and to estimate its potential exposure to users.

Methods

The new system is composed of two loops, the first loop is designed to trap background radon and thoron until their levels are nearly zero, and the second loop is the measurement loop to detect radon and thoron exhalation rates from the pillows.

Results

The results showed that mass radon exhalation rated ranged from 0.18 Bq·kg−1⋅h−1 to 0.78 Bq·kg−1⋅h−1, with an average of (0.36 ​± ​0.17) Bq·kg−1⋅h−1 in the 9 samples. The average annual effective dose to users in a model room was estimated to be (15.51 ​± ​12.69) μSv by assuming two pillows was used.

Conclusion

These results demonstrate that the new system can effectively measure radon exhalation rates in latex pillows, and the potential exposure to radon exhalating from the pillows is very low.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
乳胶枕头的氡呼出率及其对使用者的潜在暴露
目的研制一种新的乳胶枕头氡释放量准确测量系统,并评估其对使用者的潜在暴露量。方法该系统由两个回路组成,第一个回路用于捕获本底氡和钍,直到其水平接近于零;第二个回路是测量回路,用于检测枕头中氡和钍的呼气率。结果9个样品的氡质量呼出量范围为0.18 ~ 0.78 Bq·kg−1⋅h−1,平均值为(0.36±0.17)Bq·kg−1⋅h−1。假设使用两个枕头,在模拟室内对使用者的年平均有效剂量为(15.51±12.69)μSv。结论该系统能有效地测量乳胶枕头中氡的释放率,且乳胶枕头中氡的潜在暴露量很低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiation Medicine and Protection
Radiation Medicine and Protection Health Professions-Emergency Medical Services
CiteScore
2.10
自引率
0.00%
发文量
0
审稿时长
103 days
期刊最新文献
Prescription tradeoff decision support for pancreas stereotactic body radiation therapy: From templates to artificial intelligence models Reassessment of radon-induced lung cancer risk with decreasing smoking prevalence in Canada Determination of 238U and 232Th in commonly consumed foods in East China Integrin beta-1 as a critical gene in radiation-induced injury: Bioinformatic and experimental verification Assessment of knowledge, attitudes, and practices about radiation protection and safety among radiology and operating room personnel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1