Comparative Evaluation of Osseodensification vs Conventional Osteotomy Technique on Primary and Secondary Implant Stability in Rabbit Model Split Body RCT.

Sudhakar Arpudaswamy, S Syed A Ali, Suma Karthigeyan, Ponnanna A Appanna, K Vinod Kumar, Rohit M Shetty
{"title":"Comparative Evaluation of Osseodensification vs Conventional Osteotomy Technique on Primary and Secondary Implant Stability in Rabbit Model Split Body RCT.","authors":"Sudhakar Arpudaswamy, S Syed A Ali, Suma Karthigeyan, Ponnanna A Appanna, K Vinod Kumar, Rohit M Shetty","doi":"10.5005/jp-journals-10024-3751","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim and objective: </strong>To measure and contrast primary stability metrics, such as insertion torque values and implant stability quotient (IQS) at the time of implant placement, and secondary stability metrics, such as ISQ three months post-implant insertion, between implants inserted in osteotomy sites prepared with conventional drills and osseodensification drills (OD) in the femoral condyles of female New Zealand white rabbits, which are characterized by low-density D4 type bone.</p><p><strong>Materials and methods: </strong>Eight female New Zealand white strain rabbits, each 14 weeks old and weighing approximately 2.5 ± 0.3 kg, were utilized for this study. Using aseptic techniques and local anesthesia, a 3.1 × 8 mm implant was inserted into the rabbit's left femoral condyle using conventional drills (group I) from the Zimmer surgical kit. Similarly, using Densah drills (group II), a 3.1 mm × 8 mm implant was inserted into the rabbit's right femoral condyle. Primary implant stability was evaluated using insertional torque and ISQ values during insertion of implants using a torque wrench and radiofrequency analyzer, respectively. Secondary implant stability was evaluated by measuring ISQ values three months after implant placement.</p><p><strong>Results: </strong>Group I had a mean insertional torque of 31.13 ± 1.727 Ncm, while group II had 33.00 ± 1.309 Ncm. ISQ during insertion was 63.63 ± 5.927 in group I and 63.62 ± 7.615 in group II. After three months, ISQ was 67.25 ± 6.45 in group II and 75 ± 6.85 in group II. Significant differences were found in insertional torque (<i>p</i> = 0.028), ISQ after three months (<i>p</i> = 0.0353), and ISQ changes over time (<i>p</i> = 0.001), but not in ISQ at the time of implant placement.</p><p><strong>Conclusion: </strong>The investigation demonstrated that implants placed using the OD exhibited superior initial stability and subsequent stability progression compared to those placed using conventional drilling techniques in a rabbit model.</p><p><strong>Clinical significance: </strong>Primary and secondary implant stability are critical factors for successful implant treatment in clinical practice. Osseodensification demonstrates a higher insertional torque and implant stability quotient by enhancing bone density and volume surrounding implants. This enhanced stability can lead to improved osseointegration and reduced healing times, ultimately benefiting patients with compromised bone quality. How to cite this article: Arpudaswamy S, Ali SSA, Karthigeyan S, <i>et al.</i> Comparative Evaluation of Osseodensification vs Conventional Osteotomy Technique on Primary and Secondary Implant Stability in Rabbit Model Split Body RCT. J Contemp Dent Pract 2024;25(11):1052-1059.</p>","PeriodicalId":35792,"journal":{"name":"Journal of Contemporary Dental Practice","volume":"25 11","pages":"1052-1059"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Dental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10024-3751","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Aim and objective: To measure and contrast primary stability metrics, such as insertion torque values and implant stability quotient (IQS) at the time of implant placement, and secondary stability metrics, such as ISQ three months post-implant insertion, between implants inserted in osteotomy sites prepared with conventional drills and osseodensification drills (OD) in the femoral condyles of female New Zealand white rabbits, which are characterized by low-density D4 type bone.

Materials and methods: Eight female New Zealand white strain rabbits, each 14 weeks old and weighing approximately 2.5 ± 0.3 kg, were utilized for this study. Using aseptic techniques and local anesthesia, a 3.1 × 8 mm implant was inserted into the rabbit's left femoral condyle using conventional drills (group I) from the Zimmer surgical kit. Similarly, using Densah drills (group II), a 3.1 mm × 8 mm implant was inserted into the rabbit's right femoral condyle. Primary implant stability was evaluated using insertional torque and ISQ values during insertion of implants using a torque wrench and radiofrequency analyzer, respectively. Secondary implant stability was evaluated by measuring ISQ values three months after implant placement.

Results: Group I had a mean insertional torque of 31.13 ± 1.727 Ncm, while group II had 33.00 ± 1.309 Ncm. ISQ during insertion was 63.63 ± 5.927 in group I and 63.62 ± 7.615 in group II. After three months, ISQ was 67.25 ± 6.45 in group II and 75 ± 6.85 in group II. Significant differences were found in insertional torque (p = 0.028), ISQ after three months (p = 0.0353), and ISQ changes over time (p = 0.001), but not in ISQ at the time of implant placement.

Conclusion: The investigation demonstrated that implants placed using the OD exhibited superior initial stability and subsequent stability progression compared to those placed using conventional drilling techniques in a rabbit model.

Clinical significance: Primary and secondary implant stability are critical factors for successful implant treatment in clinical practice. Osseodensification demonstrates a higher insertional torque and implant stability quotient by enhancing bone density and volume surrounding implants. This enhanced stability can lead to improved osseointegration and reduced healing times, ultimately benefiting patients with compromised bone quality. How to cite this article: Arpudaswamy S, Ali SSA, Karthigeyan S, et al. Comparative Evaluation of Osseodensification vs Conventional Osteotomy Technique on Primary and Secondary Implant Stability in Rabbit Model Split Body RCT. J Contemp Dent Pract 2024;25(11):1052-1059.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
骨增生与传统截骨技术在兔模型裂体 RCT 中对主要和次要种植体稳定性的比较评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Contemporary Dental Practice
Journal of Contemporary Dental Practice Dentistry-Dentistry (all)
CiteScore
1.80
自引率
0.00%
发文量
174
期刊介绍: The Journal of Contemporary Dental Practice (JCDP), is a peer-reviewed, open access MEDLINE indexed journal. The journal’s full text is available online at http://www.thejcdp.com. The journal allows free access (open access) to its contents. Articles with clinical relevance will be given preference for publication. The Journal publishes original research papers, review articles, rare and novel case reports, and clinical techniques. Manuscripts are invited from all specialties of dentistry i.e., conservative dentistry and endodontics, dentofacial orthopedics and orthodontics, oral medicine and radiology, oral pathology, oral surgery, orodental diseases, pediatric dentistry, implantology, periodontics, clinical aspects of public health dentistry, and prosthodontics.
期刊最新文献
An Appraisal of Dental Students' Perception of Integrating Reflective Practice into the Curriculum: A Pre-Post Intervention Study. Assessment of Treatment Outcomes with Complete Orthograde Obturation with Bioceramic Materials: A Scoping Review. Clinical Evaluation of Bulk-fill Alkasite Restoration vs Resin-modified Glass Ionomer in Class V Carious Lesions: 1-year Randomized Clinical Trial. Comparative Evaluation of Effectiveness of Reciprocating and Rotary Files in Children: A Systematic Review and Meta-analysis. Comparative Evaluation of Efficacy of Resin-modified Glass Ionomer Cement and Light-curable Tricalcium Silicate Cement as Indirect Pulp Capping Materials: A Randomized Clinical Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1